Cargando…

Digital Subtraction Phonocardiography (DSP) applied to the detection and characterization of heart murmurs

BACKGROUND: During the cardiac cycle, the heart normally produces repeatable physiological sounds. However, under pathologic conditions, such as with heart valve stenosis or a ventricular septal defect, blood flow turbulence leads to the production of additional sounds, called murmurs. Murmurs are r...

Descripción completa

Detalles Bibliográficos
Autores principales: Ali Akbari, Mohammad, Hassani, Kamran, Doyle, John D, Navidbakhsh, Mahdi, Sangargir, Maryam, Bajelani, Kourosh, Ahmadi, Zahra Sadat
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3258229/
https://www.ncbi.nlm.nih.gov/pubmed/22185298
http://dx.doi.org/10.1186/1475-925X-10-109
_version_ 1782221254661505024
author Ali Akbari, Mohammad
Hassani, Kamran
Doyle, John D
Navidbakhsh, Mahdi
Sangargir, Maryam
Bajelani, Kourosh
Ahmadi, Zahra Sadat
author_facet Ali Akbari, Mohammad
Hassani, Kamran
Doyle, John D
Navidbakhsh, Mahdi
Sangargir, Maryam
Bajelani, Kourosh
Ahmadi, Zahra Sadat
author_sort Ali Akbari, Mohammad
collection PubMed
description BACKGROUND: During the cardiac cycle, the heart normally produces repeatable physiological sounds. However, under pathologic conditions, such as with heart valve stenosis or a ventricular septal defect, blood flow turbulence leads to the production of additional sounds, called murmurs. Murmurs are random in nature, while the underlying heart sounds are not (being deterministic). INNOVATION: We show that a new analytical technique, which we call Digital Subtraction Phonocardiography (DSP), can be used to separate the random murmur component of the phonocardiogram from the underlying deterministic heart sounds. METHODS: We digitally recorded the phonocardiogram from the anterior chest wall in 60 infants and adults using a high-speed USB interface and the program Gold Wave http://www.goldwave.com. The recordings included individuals with cardiac structural disease as well as recordings from normal individuals and from individuals with innocent heart murmurs. Digital Subtraction Analysis of the signal was performed using a custom computer program called Murmurgram. In essence, this program subtracts the recorded sound from two adjacent cardiac cycles to produce a difference signal, herein called a "murmurgram". Other software used included Spectrogram (Version 16), GoldWave (Version 5.55) as well as custom MATLAB code. RESULTS: Our preliminary data is presented as a series of eight cases. These cases show how advanced signal processing techniques can be used to separate heart sounds from murmurs. Note that these results are preliminary in that normal ranges for obtained test results have not yet been established. CONCLUSIONS: Cardiac murmurs can be separated from underlying deterministic heart sounds using DSP. DSP has the potential to become a reliable and economical new diagnostic approach to screening for structural heart disease. However, DSP must be further evaluated in a large series of patients with well-characterized pathology to determine its clinical potential.
format Online
Article
Text
id pubmed-3258229
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-32582292012-01-14 Digital Subtraction Phonocardiography (DSP) applied to the detection and characterization of heart murmurs Ali Akbari, Mohammad Hassani, Kamran Doyle, John D Navidbakhsh, Mahdi Sangargir, Maryam Bajelani, Kourosh Ahmadi, Zahra Sadat Biomed Eng Online Research BACKGROUND: During the cardiac cycle, the heart normally produces repeatable physiological sounds. However, under pathologic conditions, such as with heart valve stenosis or a ventricular septal defect, blood flow turbulence leads to the production of additional sounds, called murmurs. Murmurs are random in nature, while the underlying heart sounds are not (being deterministic). INNOVATION: We show that a new analytical technique, which we call Digital Subtraction Phonocardiography (DSP), can be used to separate the random murmur component of the phonocardiogram from the underlying deterministic heart sounds. METHODS: We digitally recorded the phonocardiogram from the anterior chest wall in 60 infants and adults using a high-speed USB interface and the program Gold Wave http://www.goldwave.com. The recordings included individuals with cardiac structural disease as well as recordings from normal individuals and from individuals with innocent heart murmurs. Digital Subtraction Analysis of the signal was performed using a custom computer program called Murmurgram. In essence, this program subtracts the recorded sound from two adjacent cardiac cycles to produce a difference signal, herein called a "murmurgram". Other software used included Spectrogram (Version 16), GoldWave (Version 5.55) as well as custom MATLAB code. RESULTS: Our preliminary data is presented as a series of eight cases. These cases show how advanced signal processing techniques can be used to separate heart sounds from murmurs. Note that these results are preliminary in that normal ranges for obtained test results have not yet been established. CONCLUSIONS: Cardiac murmurs can be separated from underlying deterministic heart sounds using DSP. DSP has the potential to become a reliable and economical new diagnostic approach to screening for structural heart disease. However, DSP must be further evaluated in a large series of patients with well-characterized pathology to determine its clinical potential. BioMed Central 2011-12-20 /pmc/articles/PMC3258229/ /pubmed/22185298 http://dx.doi.org/10.1186/1475-925X-10-109 Text en Copyright ©2011 Ali Akbari et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Ali Akbari, Mohammad
Hassani, Kamran
Doyle, John D
Navidbakhsh, Mahdi
Sangargir, Maryam
Bajelani, Kourosh
Ahmadi, Zahra Sadat
Digital Subtraction Phonocardiography (DSP) applied to the detection and characterization of heart murmurs
title Digital Subtraction Phonocardiography (DSP) applied to the detection and characterization of heart murmurs
title_full Digital Subtraction Phonocardiography (DSP) applied to the detection and characterization of heart murmurs
title_fullStr Digital Subtraction Phonocardiography (DSP) applied to the detection and characterization of heart murmurs
title_full_unstemmed Digital Subtraction Phonocardiography (DSP) applied to the detection and characterization of heart murmurs
title_short Digital Subtraction Phonocardiography (DSP) applied to the detection and characterization of heart murmurs
title_sort digital subtraction phonocardiography (dsp) applied to the detection and characterization of heart murmurs
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3258229/
https://www.ncbi.nlm.nih.gov/pubmed/22185298
http://dx.doi.org/10.1186/1475-925X-10-109
work_keys_str_mv AT aliakbarimohammad digitalsubtractionphonocardiographydspappliedtothedetectionandcharacterizationofheartmurmurs
AT hassanikamran digitalsubtractionphonocardiographydspappliedtothedetectionandcharacterizationofheartmurmurs
AT doylejohnd digitalsubtractionphonocardiographydspappliedtothedetectionandcharacterizationofheartmurmurs
AT navidbakhshmahdi digitalsubtractionphonocardiographydspappliedtothedetectionandcharacterizationofheartmurmurs
AT sangargirmaryam digitalsubtractionphonocardiographydspappliedtothedetectionandcharacterizationofheartmurmurs
AT bajelanikourosh digitalsubtractionphonocardiographydspappliedtothedetectionandcharacterizationofheartmurmurs
AT ahmadizahrasadat digitalsubtractionphonocardiographydspappliedtothedetectionandcharacterizationofheartmurmurs