Right atrial appendage pacing in cardiac resynchronization therapy – haemodynamic consequences of interatrial conduction delay

The present case report describes a patient with an artificial mitral valve and dual chamber pacemaker implanted due to perioperative complete atrio-ventricular block. One year later an upgrade to cardiac resynchronization therapy (CRT) combined with ICD function was performed due to significant pro...

Descripción completa

Detalles Bibliográficos
Autores principales: Dąbrowska-Kugacka, Alicja, Lewicka, Ewa, Faran, Anna, Kozłowski, Dariusz, Kempa, Maciej, Raczak, Grzegorz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3258784/
https://www.ncbi.nlm.nih.gov/pubmed/22291812
http://dx.doi.org/10.5114/aoms.2011.24146
_version_ 1782221315614179328
author Dąbrowska-Kugacka, Alicja
Lewicka, Ewa
Faran, Anna
Kozłowski, Dariusz
Kempa, Maciej
Raczak, Grzegorz
author_facet Dąbrowska-Kugacka, Alicja
Lewicka, Ewa
Faran, Anna
Kozłowski, Dariusz
Kempa, Maciej
Raczak, Grzegorz
author_sort Dąbrowska-Kugacka, Alicja
collection PubMed
description The present case report describes a patient with an artificial mitral valve and dual chamber pacemaker implanted due to perioperative complete atrio-ventricular block. One year later an upgrade to cardiac resynchronization therapy (CRT) combined with ICD function was performed due to significant progression of heart failure symptoms. Beneficial effects of CRT are demonstrated, but unfavourable haemodynamic consequences of right atrial appendage pacing are also underlined. Important interatrial conduction delay during atrial paced rhythm resulted in a significant time difference between optimal sensed and paced atrio-ventricular delay (AVD). This report provides a practical outline how to determine the interatrial delay and the sensed-paced AVD offset under echocardiography in patients treated with CRT.
format Online
Article
Text
id pubmed-3258784
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-32587842012-01-30 Right atrial appendage pacing in cardiac resynchronization therapy – haemodynamic consequences of interatrial conduction delay Dąbrowska-Kugacka, Alicja Lewicka, Ewa Faran, Anna Kozłowski, Dariusz Kempa, Maciej Raczak, Grzegorz Arch Med Sci Case Report The present case report describes a patient with an artificial mitral valve and dual chamber pacemaker implanted due to perioperative complete atrio-ventricular block. One year later an upgrade to cardiac resynchronization therapy (CRT) combined with ICD function was performed due to significant progression of heart failure symptoms. Beneficial effects of CRT are demonstrated, but unfavourable haemodynamic consequences of right atrial appendage pacing are also underlined. Important interatrial conduction delay during atrial paced rhythm resulted in a significant time difference between optimal sensed and paced atrio-ventricular delay (AVD). This report provides a practical outline how to determine the interatrial delay and the sensed-paced AVD offset under echocardiography in patients treated with CRT. Termedia Publishing House 2011-08 2011-09-02 /pmc/articles/PMC3258784/ /pubmed/22291812 http://dx.doi.org/10.5114/aoms.2011.24146 Text en Copyright © 2011 Termedia & Banach http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Dąbrowska-Kugacka, Alicja
Lewicka, Ewa
Faran, Anna
Kozłowski, Dariusz
Kempa, Maciej
Raczak, Grzegorz
Right atrial appendage pacing in cardiac resynchronization therapy – haemodynamic consequences of interatrial conduction delay
title Right atrial appendage pacing in cardiac resynchronization therapy – haemodynamic consequences of interatrial conduction delay
title_full Right atrial appendage pacing in cardiac resynchronization therapy – haemodynamic consequences of interatrial conduction delay
title_fullStr Right atrial appendage pacing in cardiac resynchronization therapy – haemodynamic consequences of interatrial conduction delay
title_full_unstemmed Right atrial appendage pacing in cardiac resynchronization therapy – haemodynamic consequences of interatrial conduction delay
title_short Right atrial appendage pacing in cardiac resynchronization therapy – haemodynamic consequences of interatrial conduction delay
title_sort right atrial appendage pacing in cardiac resynchronization therapy – haemodynamic consequences of interatrial conduction delay
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3258784/
https://www.ncbi.nlm.nih.gov/pubmed/22291812
http://dx.doi.org/10.5114/aoms.2011.24146
work_keys_str_mv AT dabrowskakugackaalicja rightatrialappendagepacingincardiacresynchronizationtherapyhaemodynamicconsequencesofinteratrialconductiondelay
AT lewickaewa rightatrialappendagepacingincardiacresynchronizationtherapyhaemodynamicconsequencesofinteratrialconductiondelay
AT farananna rightatrialappendagepacingincardiacresynchronizationtherapyhaemodynamicconsequencesofinteratrialconductiondelay
AT kozłowskidariusz rightatrialappendagepacingincardiacresynchronizationtherapyhaemodynamicconsequencesofinteratrialconductiondelay
AT kempamaciej rightatrialappendagepacingincardiacresynchronizationtherapyhaemodynamicconsequencesofinteratrialconductiondelay
AT raczakgrzegorz rightatrialappendagepacingincardiacresynchronizationtherapyhaemodynamicconsequencesofinteratrialconductiondelay