Cargando…

Accuracy of five implant impression technique: effect of splinting materials and methods

PURPOSE: The aim of this study was to evaluate the effect of dimensional stability of splinting material on the accuracy of master casts. MATERIALS AND METHODS: A stainless steel metal model with 6 implants embedded was used as a master model. Implant level impressions were made after square impress...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Sang-Jik, Cho, Sung-Bum
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3259442/
https://www.ncbi.nlm.nih.gov/pubmed/22259700
http://dx.doi.org/10.4047/jap.2011.3.4.177
_version_ 1782221389574438912
author Lee, Sang-Jik
Cho, Sung-Bum
author_facet Lee, Sang-Jik
Cho, Sung-Bum
author_sort Lee, Sang-Jik
collection PubMed
description PURPOSE: The aim of this study was to evaluate the effect of dimensional stability of splinting material on the accuracy of master casts. MATERIALS AND METHODS: A stainless steel metal model with 6 implants embedded was used as a master model. Implant level impressions were made after square impression copings were splinted using 5 different techniques as follows. (1) Splinted with autopolymerizing resin and sectioned, reconnected to compensate polymerization shrinkage before the impression procedure. (2) Splinted with autopolymerizing resin just before impression procedure. (3) Primary impression made with impression plaster and secondary impression were made over with polyether impression material. (4) Splinted with impression plaster. (5) Splinted with VPS bite registration material. From master model, 5 impressions and 5 experimental casts, total 25 casts were made for each of 5 splinting methods. The distortion values of each splinting methods were measured using coordinate measuring machine, capable of recordings in the x-, y-, z-axes. A one-way analysis of variance (ANOVA) at a confidence level of 95% was used to evaluate the data and Tukey's studentized range test was used to determine significant differences between the groups. RESULTS: Group 1 showed best accuracy followed by Group 3 & 4. Group 2 and 5 showed relatively larger distortion value than other groups. No significant difference was found between group 3, 4, 5 in x-axis, group 2, 3, 4 in y-axis and group 1, 3, 4, 5 in z-axis (P<.0001). CONCLUSION: Both Splinting impression copings with autopolymerizing resin following compensation of polymerization shrinkage and splinting method with impression plaster can enhance the accuracy of master cast and impression plaster can be used simple and effective splinting material for implant impression procedure.
format Online
Article
Text
id pubmed-3259442
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-32594422012-01-18 Accuracy of five implant impression technique: effect of splinting materials and methods Lee, Sang-Jik Cho, Sung-Bum J Adv Prosthodont Original Article PURPOSE: The aim of this study was to evaluate the effect of dimensional stability of splinting material on the accuracy of master casts. MATERIALS AND METHODS: A stainless steel metal model with 6 implants embedded was used as a master model. Implant level impressions were made after square impression copings were splinted using 5 different techniques as follows. (1) Splinted with autopolymerizing resin and sectioned, reconnected to compensate polymerization shrinkage before the impression procedure. (2) Splinted with autopolymerizing resin just before impression procedure. (3) Primary impression made with impression plaster and secondary impression were made over with polyether impression material. (4) Splinted with impression plaster. (5) Splinted with VPS bite registration material. From master model, 5 impressions and 5 experimental casts, total 25 casts were made for each of 5 splinting methods. The distortion values of each splinting methods were measured using coordinate measuring machine, capable of recordings in the x-, y-, z-axes. A one-way analysis of variance (ANOVA) at a confidence level of 95% was used to evaluate the data and Tukey's studentized range test was used to determine significant differences between the groups. RESULTS: Group 1 showed best accuracy followed by Group 3 & 4. Group 2 and 5 showed relatively larger distortion value than other groups. No significant difference was found between group 3, 4, 5 in x-axis, group 2, 3, 4 in y-axis and group 1, 3, 4, 5 in z-axis (P<.0001). CONCLUSION: Both Splinting impression copings with autopolymerizing resin following compensation of polymerization shrinkage and splinting method with impression plaster can enhance the accuracy of master cast and impression plaster can be used simple and effective splinting material for implant impression procedure. The Korean Academy of Prosthodontics 2011-12 2011-12-28 /pmc/articles/PMC3259442/ /pubmed/22259700 http://dx.doi.org/10.4047/jap.2011.3.4.177 Text en © 2011 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Sang-Jik
Cho, Sung-Bum
Accuracy of five implant impression technique: effect of splinting materials and methods
title Accuracy of five implant impression technique: effect of splinting materials and methods
title_full Accuracy of five implant impression technique: effect of splinting materials and methods
title_fullStr Accuracy of five implant impression technique: effect of splinting materials and methods
title_full_unstemmed Accuracy of five implant impression technique: effect of splinting materials and methods
title_short Accuracy of five implant impression technique: effect of splinting materials and methods
title_sort accuracy of five implant impression technique: effect of splinting materials and methods
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3259442/
https://www.ncbi.nlm.nih.gov/pubmed/22259700
http://dx.doi.org/10.4047/jap.2011.3.4.177
work_keys_str_mv AT leesangjik accuracyoffiveimplantimpressiontechniqueeffectofsplintingmaterialsandmethods
AT chosungbum accuracyoffiveimplantimpressiontechniqueeffectofsplintingmaterialsandmethods