Cargando…
A Comparison of Portable Ultrasound and Fully-Equipped Clinical Ultrasound Unit in the Thyroid Size Measurement of the Indo-Pacific Bottlenose Dolphin
Measurement of thyroid size and volume is a useful clinical parameter in both human and veterinary medicine, particularly for diagnosing thyroid diseases and guiding corrective therapy. Procuring a fully-equipped clinical ultrasound unit (FCUS) may be difficult in most veterinary settings. The prese...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3260256/ https://www.ncbi.nlm.nih.gov/pubmed/22272311 http://dx.doi.org/10.1371/journal.pone.0030218 |
_version_ | 1782221470350442496 |
---|---|
author | Kot, Brian C. W. Ying, Michael T. C. Brook, Fiona M. |
author_facet | Kot, Brian C. W. Ying, Michael T. C. Brook, Fiona M. |
author_sort | Kot, Brian C. W. |
collection | PubMed |
description | Measurement of thyroid size and volume is a useful clinical parameter in both human and veterinary medicine, particularly for diagnosing thyroid diseases and guiding corrective therapy. Procuring a fully-equipped clinical ultrasound unit (FCUS) may be difficult in most veterinary settings. The present study evaluated the inter-equipment variability in dolphin thyroid ultrasound measurements between a portable ultrasound unit (PUS) and a FCUS; for both units, repeatability was also assessed. Thyroid ultrasound examinations were performed on 15 apparently healthy bottlenose dolphins with both PUS and FCUS under identical scanning conditions. There was a high level of agreement between the two ultrasound units in dolphin thyroid measurements (ICC = 0.859–0.976). A high intra-operator repeatability in thyroid measurements was found (PUS: ICC = 0.854–0.984, FCUS: ICC = 0.709–0.954). As a conclusion, no substantial inter-equipment variability was found between PUS and FCUS in dolphin thyroid size measurements under identical scanning conditions, supporting further application of PUS for quantitative analyses of dolphin thyroid gland in both research and clinical practices at aquarium settings. |
format | Online Article Text |
id | pubmed-3260256 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-32602562012-01-23 A Comparison of Portable Ultrasound and Fully-Equipped Clinical Ultrasound Unit in the Thyroid Size Measurement of the Indo-Pacific Bottlenose Dolphin Kot, Brian C. W. Ying, Michael T. C. Brook, Fiona M. PLoS One Research Article Measurement of thyroid size and volume is a useful clinical parameter in both human and veterinary medicine, particularly for diagnosing thyroid diseases and guiding corrective therapy. Procuring a fully-equipped clinical ultrasound unit (FCUS) may be difficult in most veterinary settings. The present study evaluated the inter-equipment variability in dolphin thyroid ultrasound measurements between a portable ultrasound unit (PUS) and a FCUS; for both units, repeatability was also assessed. Thyroid ultrasound examinations were performed on 15 apparently healthy bottlenose dolphins with both PUS and FCUS under identical scanning conditions. There was a high level of agreement between the two ultrasound units in dolphin thyroid measurements (ICC = 0.859–0.976). A high intra-operator repeatability in thyroid measurements was found (PUS: ICC = 0.854–0.984, FCUS: ICC = 0.709–0.954). As a conclusion, no substantial inter-equipment variability was found between PUS and FCUS in dolphin thyroid size measurements under identical scanning conditions, supporting further application of PUS for quantitative analyses of dolphin thyroid gland in both research and clinical practices at aquarium settings. Public Library of Science 2012-01-17 /pmc/articles/PMC3260256/ /pubmed/22272311 http://dx.doi.org/10.1371/journal.pone.0030218 Text en Kot et al. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Kot, Brian C. W. Ying, Michael T. C. Brook, Fiona M. A Comparison of Portable Ultrasound and Fully-Equipped Clinical Ultrasound Unit in the Thyroid Size Measurement of the Indo-Pacific Bottlenose Dolphin |
title | A Comparison of Portable Ultrasound and Fully-Equipped Clinical Ultrasound Unit in the Thyroid Size Measurement of the Indo-Pacific Bottlenose Dolphin |
title_full | A Comparison of Portable Ultrasound and Fully-Equipped Clinical Ultrasound Unit in the Thyroid Size Measurement of the Indo-Pacific Bottlenose Dolphin |
title_fullStr | A Comparison of Portable Ultrasound and Fully-Equipped Clinical Ultrasound Unit in the Thyroid Size Measurement of the Indo-Pacific Bottlenose Dolphin |
title_full_unstemmed | A Comparison of Portable Ultrasound and Fully-Equipped Clinical Ultrasound Unit in the Thyroid Size Measurement of the Indo-Pacific Bottlenose Dolphin |
title_short | A Comparison of Portable Ultrasound and Fully-Equipped Clinical Ultrasound Unit in the Thyroid Size Measurement of the Indo-Pacific Bottlenose Dolphin |
title_sort | comparison of portable ultrasound and fully-equipped clinical ultrasound unit in the thyroid size measurement of the indo-pacific bottlenose dolphin |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3260256/ https://www.ncbi.nlm.nih.gov/pubmed/22272311 http://dx.doi.org/10.1371/journal.pone.0030218 |
work_keys_str_mv | AT kotbriancw acomparisonofportableultrasoundandfullyequippedclinicalultrasoundunitinthethyroidsizemeasurementoftheindopacificbottlenosedolphin AT yingmichaeltc acomparisonofportableultrasoundandfullyequippedclinicalultrasoundunitinthethyroidsizemeasurementoftheindopacificbottlenosedolphin AT brookfionam acomparisonofportableultrasoundandfullyequippedclinicalultrasoundunitinthethyroidsizemeasurementoftheindopacificbottlenosedolphin AT kotbriancw comparisonofportableultrasoundandfullyequippedclinicalultrasoundunitinthethyroidsizemeasurementoftheindopacificbottlenosedolphin AT yingmichaeltc comparisonofportableultrasoundandfullyequippedclinicalultrasoundunitinthethyroidsizemeasurementoftheindopacificbottlenosedolphin AT brookfionam comparisonofportableultrasoundandfullyequippedclinicalultrasoundunitinthethyroidsizemeasurementoftheindopacificbottlenosedolphin |