Performance Characteristics of a PEM Fuel Cell with Parallel Flow Channels at Different Cathode Relative Humidity Levels

In fuel cells flow configuration and operating conditions such as cell temperature, humidity at each electrode and stoichiometric number are very crucial for improving performance. Too many flow channels could enhance the performance but result in high parasite loss. Therefore a trade-off between pr...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Pil Hyong, Hwang, Sang Soon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3260633/
https://www.ncbi.nlm.nih.gov/pubmed/22291556
http://dx.doi.org/10.3390/s91109104
_version_ 1782221512519974912
author Lee, Pil Hyong
Hwang, Sang Soon
author_facet Lee, Pil Hyong
Hwang, Sang Soon
author_sort Lee, Pil Hyong
collection PubMed
description In fuel cells flow configuration and operating conditions such as cell temperature, humidity at each electrode and stoichiometric number are very crucial for improving performance. Too many flow channels could enhance the performance but result in high parasite loss. Therefore a trade-off between pressure drop and efficiency of a fuel cell should be considered for optimum design. This work focused on numerical simulation of the effects of operating conditions, especially cathode humidity, with simple micro parallel flow channels. It is known that the humidity at the cathode flow channel becomes very important for enhancing the ion conductivity of polymer membrane because fully humidified condition was normally set at anode. To investigate the effect of humidity on the performance of a fuel cell, in this study humidification was set to 100% at the anode flow channel and was changed by 0–100% at the cathode flow channel. Results showed that the maximum power density could be obtained under 60% humidified condition at the cathode where oxygen concentration was moderately high while maintaining high ion conductivity at a membrane.
format Online
Article
Text
id pubmed-3260633
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-32606332012-01-30 Performance Characteristics of a PEM Fuel Cell with Parallel Flow Channels at Different Cathode Relative Humidity Levels Lee, Pil Hyong Hwang, Sang Soon Sensors (Basel) Article In fuel cells flow configuration and operating conditions such as cell temperature, humidity at each electrode and stoichiometric number are very crucial for improving performance. Too many flow channels could enhance the performance but result in high parasite loss. Therefore a trade-off between pressure drop and efficiency of a fuel cell should be considered for optimum design. This work focused on numerical simulation of the effects of operating conditions, especially cathode humidity, with simple micro parallel flow channels. It is known that the humidity at the cathode flow channel becomes very important for enhancing the ion conductivity of polymer membrane because fully humidified condition was normally set at anode. To investigate the effect of humidity on the performance of a fuel cell, in this study humidification was set to 100% at the anode flow channel and was changed by 0–100% at the cathode flow channel. Results showed that the maximum power density could be obtained under 60% humidified condition at the cathode where oxygen concentration was moderately high while maintaining high ion conductivity at a membrane. Molecular Diversity Preservation International (MDPI) 2009-11-17 /pmc/articles/PMC3260633/ /pubmed/22291556 http://dx.doi.org/10.3390/s91109104 Text en © 2009 by the authors; licensee Molecular Diversity Preservation International, Basel, Switzerland. https://creativecommons.org/licenses/by/3.0/This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/ (https://creativecommons.org/licenses/by/3.0/) ).
spellingShingle Article
Lee, Pil Hyong
Hwang, Sang Soon
Performance Characteristics of a PEM Fuel Cell with Parallel Flow Channels at Different Cathode Relative Humidity Levels
title Performance Characteristics of a PEM Fuel Cell with Parallel Flow Channels at Different Cathode Relative Humidity Levels
title_full Performance Characteristics of a PEM Fuel Cell with Parallel Flow Channels at Different Cathode Relative Humidity Levels
title_fullStr Performance Characteristics of a PEM Fuel Cell with Parallel Flow Channels at Different Cathode Relative Humidity Levels
title_full_unstemmed Performance Characteristics of a PEM Fuel Cell with Parallel Flow Channels at Different Cathode Relative Humidity Levels
title_short Performance Characteristics of a PEM Fuel Cell with Parallel Flow Channels at Different Cathode Relative Humidity Levels
title_sort performance characteristics of a pem fuel cell with parallel flow channels at different cathode relative humidity levels
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3260633/
https://www.ncbi.nlm.nih.gov/pubmed/22291556
http://dx.doi.org/10.3390/s91109104
work_keys_str_mv AT leepilhyong performancecharacteristicsofapemfuelcellwithparallelflowchannelsatdifferentcathoderelativehumiditylevels
AT hwangsangsoon performancecharacteristicsofapemfuelcellwithparallelflowchannelsatdifferentcathoderelativehumiditylevels