Cargando…
Structural and functional characterization of proteins adsorbed on hydrophilized polylactide-co-glycolide microfibers
BACKGROUND: Hydrophobic biopolymers such as polylactide-co-glycolide (PLGA, 85:15) have been extensively explored as scaffolding materials for tissue engineering applications. More recently, electrospun microfiber-based and nanofiber-based scaffolds of PLGA have received increased attention because...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3260951/ https://www.ncbi.nlm.nih.gov/pubmed/22275823 http://dx.doi.org/10.2147/IJN.S26453 |
_version_ | 1782221538355838976 |
---|---|
author | Vasita, Rajesh Katti, Dhirendra S |
author_facet | Vasita, Rajesh Katti, Dhirendra S |
author_sort | Vasita, Rajesh |
collection | PubMed |
description | BACKGROUND: Hydrophobic biopolymers such as polylactide-co-glycolide (PLGA, 85:15) have been extensively explored as scaffolding materials for tissue engineering applications. More recently, electrospun microfiber-based and nanofiber-based scaffolds of PLGA have received increased attention because they act as physical mimics of the fibrillar extracellular matrix. However, the hydrophobicity of the PLGA microfiber surface can limit its use in biomedical applications. Therefore, in a previous study, we fabricated Pluronic(®) F-108 (PF-108)-blended PLGA microfibrous scaffolds that alleviated the hydrophobicity associated with PLGA by enriching the surface of microfibers with the ethylene oxide units present in PF-108. METHODS: In this study, we report the influence of the extent of surface enrichment of PLGA microfibers on their interaction with two model proteins, ie, bovine serum albumin (BSA) and lysozyme. BSA and lysozyme were adsorbed onto PLGA microfiber meshes (unmodified and modified) and studied for the amount, secondary structure conformation, and bioactivity of released protein. RESULTS: Irrespective of the type of protein, PF-108-blended PLGA microfibers showed significantly greater protein adsorption and release than the unblended PLGA samples. However, in comparison with BSA, lysozyme showed a 7–9-fold increase in release. The Fourier transform infrared spectroscopy studies for secondary structure determination demonstrated that irrespective of type of microfiber surface (unblended or blended), adsorbed BSA and lysozyme did not show any significant change in secondary structure (α-helical content) as compared with BSA and/or lysozyme in the free powder state. Further, the bioactivity assay of lysozyme released from blended PLGA microfiber meshes demonstrated 80%–85% bioactivity, indicating that the process of adsorption did not significantly affect biological activity. Therefore, this study demonstrated that the decreased hydrophobicity of blended PLGA microfibrous meshes not only improved the amount of protein adsorbed (lysozyme and BSA) but also maintained the secondary structure and bioactivity of the adsorbed proteins. CONCLUSION: Modulating the hydrophobicity of PLGA via blending with PF-108 could be a viable strategy to improve its interaction with proteins and subsequent cell interaction in tissue engineering applications. |
format | Online Article Text |
id | pubmed-3260951 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-32609512012-01-24 Structural and functional characterization of proteins adsorbed on hydrophilized polylactide-co-glycolide microfibers Vasita, Rajesh Katti, Dhirendra S Int J Nanomedicine Original Research BACKGROUND: Hydrophobic biopolymers such as polylactide-co-glycolide (PLGA, 85:15) have been extensively explored as scaffolding materials for tissue engineering applications. More recently, electrospun microfiber-based and nanofiber-based scaffolds of PLGA have received increased attention because they act as physical mimics of the fibrillar extracellular matrix. However, the hydrophobicity of the PLGA microfiber surface can limit its use in biomedical applications. Therefore, in a previous study, we fabricated Pluronic(®) F-108 (PF-108)-blended PLGA microfibrous scaffolds that alleviated the hydrophobicity associated with PLGA by enriching the surface of microfibers with the ethylene oxide units present in PF-108. METHODS: In this study, we report the influence of the extent of surface enrichment of PLGA microfibers on their interaction with two model proteins, ie, bovine serum albumin (BSA) and lysozyme. BSA and lysozyme were adsorbed onto PLGA microfiber meshes (unmodified and modified) and studied for the amount, secondary structure conformation, and bioactivity of released protein. RESULTS: Irrespective of the type of protein, PF-108-blended PLGA microfibers showed significantly greater protein adsorption and release than the unblended PLGA samples. However, in comparison with BSA, lysozyme showed a 7–9-fold increase in release. The Fourier transform infrared spectroscopy studies for secondary structure determination demonstrated that irrespective of type of microfiber surface (unblended or blended), adsorbed BSA and lysozyme did not show any significant change in secondary structure (α-helical content) as compared with BSA and/or lysozyme in the free powder state. Further, the bioactivity assay of lysozyme released from blended PLGA microfiber meshes demonstrated 80%–85% bioactivity, indicating that the process of adsorption did not significantly affect biological activity. Therefore, this study demonstrated that the decreased hydrophobicity of blended PLGA microfibrous meshes not only improved the amount of protein adsorbed (lysozyme and BSA) but also maintained the secondary structure and bioactivity of the adsorbed proteins. CONCLUSION: Modulating the hydrophobicity of PLGA via blending with PF-108 could be a viable strategy to improve its interaction with proteins and subsequent cell interaction in tissue engineering applications. Dove Medical Press 2012 2011-12-30 /pmc/articles/PMC3260951/ /pubmed/22275823 http://dx.doi.org/10.2147/IJN.S26453 Text en © 2012 Vasita and Katti, publisher and licensee Dove Medical Press Ltd. This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited. |
spellingShingle | Original Research Vasita, Rajesh Katti, Dhirendra S Structural and functional characterization of proteins adsorbed on hydrophilized polylactide-co-glycolide microfibers |
title | Structural and functional characterization of proteins adsorbed on hydrophilized polylactide-co-glycolide microfibers |
title_full | Structural and functional characterization of proteins adsorbed on hydrophilized polylactide-co-glycolide microfibers |
title_fullStr | Structural and functional characterization of proteins adsorbed on hydrophilized polylactide-co-glycolide microfibers |
title_full_unstemmed | Structural and functional characterization of proteins adsorbed on hydrophilized polylactide-co-glycolide microfibers |
title_short | Structural and functional characterization of proteins adsorbed on hydrophilized polylactide-co-glycolide microfibers |
title_sort | structural and functional characterization of proteins adsorbed on hydrophilized polylactide-co-glycolide microfibers |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3260951/ https://www.ncbi.nlm.nih.gov/pubmed/22275823 http://dx.doi.org/10.2147/IJN.S26453 |
work_keys_str_mv | AT vasitarajesh structuralandfunctionalcharacterizationofproteinsadsorbedonhydrophilizedpolylactidecoglycolidemicrofibers AT kattidhirendras structuralandfunctionalcharacterizationofproteinsadsorbedonhydrophilizedpolylactidecoglycolidemicrofibers |