Cargando…

Measurements of knee rotation-reliability of an external device in vivo

BACKGROUND: Knee rotation plays an important part in knee kinematics during weight-bearing activities. An external device for measuring knee rotation (the Rottometer) has previously been evaluated for validity by simultaneous measurements of skeletal movements with Roentgen Stereometric Analysis (RS...

Descripción completa

Detalles Bibliográficos
Autores principales: Almquist, Per O, Ekdahl, Charlotte, Isberg, Per-Erik, Fridén, Thomas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3264542/
https://www.ncbi.nlm.nih.gov/pubmed/22208736
http://dx.doi.org/10.1186/1471-2474-12-291
_version_ 1782221982519001088
author Almquist, Per O
Ekdahl, Charlotte
Isberg, Per-Erik
Fridén, Thomas
author_facet Almquist, Per O
Ekdahl, Charlotte
Isberg, Per-Erik
Fridén, Thomas
author_sort Almquist, Per O
collection PubMed
description BACKGROUND: Knee rotation plays an important part in knee kinematics during weight-bearing activities. An external device for measuring knee rotation (the Rottometer) has previously been evaluated for validity by simultaneous measurements of skeletal movements with Roentgen Stereometric Analysis (RSA). The aim of this study was to investigate the reliability of the device. METHOD: The within-day and test-retest reliability as well as intertester reliability of the device in vivo was calculated. Torques of 3, 6 and 9 Nm and the examiner's apprehension of end-feel were used at 90°, 60° and 30° of knee flexion. Intraclass Correlation Coefficient (2,1 )(ICC (2,1)), 95% confidence interval (CI) of ICC and 95% CI between test trials and examiners were used as statistical tests. RESULT: ICC(2,1 )ranged from 0.50 to 0.94 at all three flexion angles at 6 and 9 Nm as well as end-feel, and from 0.22 to 0.75 at 3 Nm applied torque. CONCLUSION: The Rottometer was a reliable measurement instrument concerning knee rotation at the three different flexion angles (90°, 60° and 30°) with 6 and 9 Nm applied torques as well as the examiner's apprehension of end-feel. Three Nm was not a reliable torque. The most reliable measurements were made at 9 Nm applied torque.
format Online
Article
Text
id pubmed-3264542
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-32645422012-01-24 Measurements of knee rotation-reliability of an external device in vivo Almquist, Per O Ekdahl, Charlotte Isberg, Per-Erik Fridén, Thomas BMC Musculoskelet Disord Research Article BACKGROUND: Knee rotation plays an important part in knee kinematics during weight-bearing activities. An external device for measuring knee rotation (the Rottometer) has previously been evaluated for validity by simultaneous measurements of skeletal movements with Roentgen Stereometric Analysis (RSA). The aim of this study was to investigate the reliability of the device. METHOD: The within-day and test-retest reliability as well as intertester reliability of the device in vivo was calculated. Torques of 3, 6 and 9 Nm and the examiner's apprehension of end-feel were used at 90°, 60° and 30° of knee flexion. Intraclass Correlation Coefficient (2,1 )(ICC (2,1)), 95% confidence interval (CI) of ICC and 95% CI between test trials and examiners were used as statistical tests. RESULT: ICC(2,1 )ranged from 0.50 to 0.94 at all three flexion angles at 6 and 9 Nm as well as end-feel, and from 0.22 to 0.75 at 3 Nm applied torque. CONCLUSION: The Rottometer was a reliable measurement instrument concerning knee rotation at the three different flexion angles (90°, 60° and 30°) with 6 and 9 Nm applied torques as well as the examiner's apprehension of end-feel. Three Nm was not a reliable torque. The most reliable measurements were made at 9 Nm applied torque. BioMed Central 2011-12-30 /pmc/articles/PMC3264542/ /pubmed/22208736 http://dx.doi.org/10.1186/1471-2474-12-291 Text en Copyright ©2011 Almquist et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Almquist, Per O
Ekdahl, Charlotte
Isberg, Per-Erik
Fridén, Thomas
Measurements of knee rotation-reliability of an external device in vivo
title Measurements of knee rotation-reliability of an external device in vivo
title_full Measurements of knee rotation-reliability of an external device in vivo
title_fullStr Measurements of knee rotation-reliability of an external device in vivo
title_full_unstemmed Measurements of knee rotation-reliability of an external device in vivo
title_short Measurements of knee rotation-reliability of an external device in vivo
title_sort measurements of knee rotation-reliability of an external device in vivo
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3264542/
https://www.ncbi.nlm.nih.gov/pubmed/22208736
http://dx.doi.org/10.1186/1471-2474-12-291
work_keys_str_mv AT almquistpero measurementsofkneerotationreliabilityofanexternaldeviceinvivo
AT ekdahlcharlotte measurementsofkneerotationreliabilityofanexternaldeviceinvivo
AT isbergpererik measurementsofkneerotationreliabilityofanexternaldeviceinvivo
AT fridenthomas measurementsofkneerotationreliabilityofanexternaldeviceinvivo