Cargando…
Measurements of knee rotation-reliability of an external device in vivo
BACKGROUND: Knee rotation plays an important part in knee kinematics during weight-bearing activities. An external device for measuring knee rotation (the Rottometer) has previously been evaluated for validity by simultaneous measurements of skeletal movements with Roentgen Stereometric Analysis (RS...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3264542/ https://www.ncbi.nlm.nih.gov/pubmed/22208736 http://dx.doi.org/10.1186/1471-2474-12-291 |
_version_ | 1782221982519001088 |
---|---|
author | Almquist, Per O Ekdahl, Charlotte Isberg, Per-Erik Fridén, Thomas |
author_facet | Almquist, Per O Ekdahl, Charlotte Isberg, Per-Erik Fridén, Thomas |
author_sort | Almquist, Per O |
collection | PubMed |
description | BACKGROUND: Knee rotation plays an important part in knee kinematics during weight-bearing activities. An external device for measuring knee rotation (the Rottometer) has previously been evaluated for validity by simultaneous measurements of skeletal movements with Roentgen Stereometric Analysis (RSA). The aim of this study was to investigate the reliability of the device. METHOD: The within-day and test-retest reliability as well as intertester reliability of the device in vivo was calculated. Torques of 3, 6 and 9 Nm and the examiner's apprehension of end-feel were used at 90°, 60° and 30° of knee flexion. Intraclass Correlation Coefficient (2,1 )(ICC (2,1)), 95% confidence interval (CI) of ICC and 95% CI between test trials and examiners were used as statistical tests. RESULT: ICC(2,1 )ranged from 0.50 to 0.94 at all three flexion angles at 6 and 9 Nm as well as end-feel, and from 0.22 to 0.75 at 3 Nm applied torque. CONCLUSION: The Rottometer was a reliable measurement instrument concerning knee rotation at the three different flexion angles (90°, 60° and 30°) with 6 and 9 Nm applied torques as well as the examiner's apprehension of end-feel. Three Nm was not a reliable torque. The most reliable measurements were made at 9 Nm applied torque. |
format | Online Article Text |
id | pubmed-3264542 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-32645422012-01-24 Measurements of knee rotation-reliability of an external device in vivo Almquist, Per O Ekdahl, Charlotte Isberg, Per-Erik Fridén, Thomas BMC Musculoskelet Disord Research Article BACKGROUND: Knee rotation plays an important part in knee kinematics during weight-bearing activities. An external device for measuring knee rotation (the Rottometer) has previously been evaluated for validity by simultaneous measurements of skeletal movements with Roentgen Stereometric Analysis (RSA). The aim of this study was to investigate the reliability of the device. METHOD: The within-day and test-retest reliability as well as intertester reliability of the device in vivo was calculated. Torques of 3, 6 and 9 Nm and the examiner's apprehension of end-feel were used at 90°, 60° and 30° of knee flexion. Intraclass Correlation Coefficient (2,1 )(ICC (2,1)), 95% confidence interval (CI) of ICC and 95% CI between test trials and examiners were used as statistical tests. RESULT: ICC(2,1 )ranged from 0.50 to 0.94 at all three flexion angles at 6 and 9 Nm as well as end-feel, and from 0.22 to 0.75 at 3 Nm applied torque. CONCLUSION: The Rottometer was a reliable measurement instrument concerning knee rotation at the three different flexion angles (90°, 60° and 30°) with 6 and 9 Nm applied torques as well as the examiner's apprehension of end-feel. Three Nm was not a reliable torque. The most reliable measurements were made at 9 Nm applied torque. BioMed Central 2011-12-30 /pmc/articles/PMC3264542/ /pubmed/22208736 http://dx.doi.org/10.1186/1471-2474-12-291 Text en Copyright ©2011 Almquist et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Almquist, Per O Ekdahl, Charlotte Isberg, Per-Erik Fridén, Thomas Measurements of knee rotation-reliability of an external device in vivo |
title | Measurements of knee rotation-reliability of an external device in vivo |
title_full | Measurements of knee rotation-reliability of an external device in vivo |
title_fullStr | Measurements of knee rotation-reliability of an external device in vivo |
title_full_unstemmed | Measurements of knee rotation-reliability of an external device in vivo |
title_short | Measurements of knee rotation-reliability of an external device in vivo |
title_sort | measurements of knee rotation-reliability of an external device in vivo |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3264542/ https://www.ncbi.nlm.nih.gov/pubmed/22208736 http://dx.doi.org/10.1186/1471-2474-12-291 |
work_keys_str_mv | AT almquistpero measurementsofkneerotationreliabilityofanexternaldeviceinvivo AT ekdahlcharlotte measurementsofkneerotationreliabilityofanexternaldeviceinvivo AT isbergpererik measurementsofkneerotationreliabilityofanexternaldeviceinvivo AT fridenthomas measurementsofkneerotationreliabilityofanexternaldeviceinvivo |