Cargando…

Flow Injection Chemiluminescent Immunoassay for Carcinoembryonic Antigen Using Boronic Immunoaffinity Column

A flow injection chemiluminescence immunoassay for rapid and sensitive detection of carcinoembryonic antigen (CEA) by using a phenylboronic acid-based immunoaffinity column as a glycoprotein collector was proposed in this paper. The column was prepared by coupling of 3-aminophenylboronic acid on the...

Descripción completa

Detalles Bibliográficos
Autores principales: Ma, Xiaoling, Li, Huihui, Wu, Min, Sun, Chong, Li, Laifa, Yang, Xiaodi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3267227/
https://www.ncbi.nlm.nih.gov/pubmed/22303179
http://dx.doi.org/10.3390/s91210389
_version_ 1782222265044172800
author Ma, Xiaoling
Li, Huihui
Wu, Min
Sun, Chong
Li, Laifa
Yang, Xiaodi
author_facet Ma, Xiaoling
Li, Huihui
Wu, Min
Sun, Chong
Li, Laifa
Yang, Xiaodi
author_sort Ma, Xiaoling
collection PubMed
description A flow injection chemiluminescence immunoassay for rapid and sensitive detection of carcinoembryonic antigen (CEA) by using a phenylboronic acid-based immunoaffinity column as a glycoprotein collector was proposed in this paper. The column was prepared by coupling of 3-aminophenylboronic acid on the glass beads through a γ-glycidoxypropyltrimethoxysilane (GPMS) linkage. Based on an indirect competitive immunoreaction, the mixture of CEA sample and enzyme conjugated CEA antibody (HRP-anti-CEA) was incubated in advance, followed by direct injection to the column to capture free HRP-labeled CEA antibody in the column. The trapped HRP-labeled antibody was detected by flow inject chemiluminescence in the presence of luminol and hydrogen peroxide. The decreased chemiluminescent signal was proportional to the concentration of CEA in the range of 3.0–30.0 ng/mL with a correlation coefficient of 0.998. The column showed an acceptable reproducibility and stability and is potentially used for practical clinical detection of the serum CEA level.
format Online
Article
Text
id pubmed-3267227
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-32672272012-02-02 Flow Injection Chemiluminescent Immunoassay for Carcinoembryonic Antigen Using Boronic Immunoaffinity Column Ma, Xiaoling Li, Huihui Wu, Min Sun, Chong Li, Laifa Yang, Xiaodi Sensors (Basel) Article A flow injection chemiluminescence immunoassay for rapid and sensitive detection of carcinoembryonic antigen (CEA) by using a phenylboronic acid-based immunoaffinity column as a glycoprotein collector was proposed in this paper. The column was prepared by coupling of 3-aminophenylboronic acid on the glass beads through a γ-glycidoxypropyltrimethoxysilane (GPMS) linkage. Based on an indirect competitive immunoreaction, the mixture of CEA sample and enzyme conjugated CEA antibody (HRP-anti-CEA) was incubated in advance, followed by direct injection to the column to capture free HRP-labeled CEA antibody in the column. The trapped HRP-labeled antibody was detected by flow inject chemiluminescence in the presence of luminol and hydrogen peroxide. The decreased chemiluminescent signal was proportional to the concentration of CEA in the range of 3.0–30.0 ng/mL with a correlation coefficient of 0.998. The column showed an acceptable reproducibility and stability and is potentially used for practical clinical detection of the serum CEA level. Molecular Diversity Preservation International (MDPI) 2009-12-21 /pmc/articles/PMC3267227/ /pubmed/22303179 http://dx.doi.org/10.3390/s91210389 Text en © 2009 by the authors; licensee Molecular Diversity Preservation International, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Ma, Xiaoling
Li, Huihui
Wu, Min
Sun, Chong
Li, Laifa
Yang, Xiaodi
Flow Injection Chemiluminescent Immunoassay for Carcinoembryonic Antigen Using Boronic Immunoaffinity Column
title Flow Injection Chemiluminescent Immunoassay for Carcinoembryonic Antigen Using Boronic Immunoaffinity Column
title_full Flow Injection Chemiluminescent Immunoassay for Carcinoembryonic Antigen Using Boronic Immunoaffinity Column
title_fullStr Flow Injection Chemiluminescent Immunoassay for Carcinoembryonic Antigen Using Boronic Immunoaffinity Column
title_full_unstemmed Flow Injection Chemiluminescent Immunoassay for Carcinoembryonic Antigen Using Boronic Immunoaffinity Column
title_short Flow Injection Chemiluminescent Immunoassay for Carcinoembryonic Antigen Using Boronic Immunoaffinity Column
title_sort flow injection chemiluminescent immunoassay for carcinoembryonic antigen using boronic immunoaffinity column
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3267227/
https://www.ncbi.nlm.nih.gov/pubmed/22303179
http://dx.doi.org/10.3390/s91210389
work_keys_str_mv AT maxiaoling flowinjectionchemiluminescentimmunoassayforcarcinoembryonicantigenusingboronicimmunoaffinitycolumn
AT lihuihui flowinjectionchemiluminescentimmunoassayforcarcinoembryonicantigenusingboronicimmunoaffinitycolumn
AT wumin flowinjectionchemiluminescentimmunoassayforcarcinoembryonicantigenusingboronicimmunoaffinitycolumn
AT sunchong flowinjectionchemiluminescentimmunoassayforcarcinoembryonicantigenusingboronicimmunoaffinitycolumn
AT lilaifa flowinjectionchemiluminescentimmunoassayforcarcinoembryonicantigenusingboronicimmunoaffinitycolumn
AT yangxiaodi flowinjectionchemiluminescentimmunoassayforcarcinoembryonicantigenusingboronicimmunoaffinitycolumn