Cargando…

Simultaneous Determination of Withanolide A and Bacoside A in Spansules by High-Performance Thin-Layer Chromatography

The objective of this work was to develop and validate a simple, rapid, precise, and accurate high performance thin layer chromatography method for simultaneous determination of withanolide A and bacoside A in combined dosage form. The stationary phase used was silica gel G60F(254). The mobile phase...

Descripción completa

Detalles Bibliográficos
Autores principales: Shinde, P B, Aragade, P D, Agrawal, M R, Deokate, U A, Khadabadi, S S
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3267314/
https://www.ncbi.nlm.nih.gov/pubmed/22303073
_version_ 1782222272261521408
author Shinde, P B
Aragade, P D
Agrawal, M R
Deokate, U A
Khadabadi, S S
author_facet Shinde, P B
Aragade, P D
Agrawal, M R
Deokate, U A
Khadabadi, S S
author_sort Shinde, P B
collection PubMed
description The objective of this work was to develop and validate a simple, rapid, precise, and accurate high performance thin layer chromatography method for simultaneous determination of withanolide A and bacoside A in combined dosage form. The stationary phase used was silica gel G60F(254). The mobile phase used was mixture of ethyl acetate: methanol: toluene: water (4:1:1:0.5 v/v/v/v). The detection of spots was carried out at 320 nm using absorbance reflectance mode. The method was validated in terms of linearity, accuracy, precision and specificity. The calibration curve was found to be linear between 200 to 800 ng/spot for withanolide A and 50 to 350 ng/spot for bacoside A. The limit of detection and limit of quantification for the withanolide A were found to be 3.05 and 10.06 ng/spot, respectively and for bacoside A 8.3 and 27.39 ng/spot, respectively. The proposed method can be successfully used to determine the drug content of marketed formulation.
format Online
Article
Text
id pubmed-3267314
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-32673142012-02-02 Simultaneous Determination of Withanolide A and Bacoside A in Spansules by High-Performance Thin-Layer Chromatography Shinde, P B Aragade, P D Agrawal, M R Deokate, U A Khadabadi, S S Indian J Pharm Sci Short Communications The objective of this work was to develop and validate a simple, rapid, precise, and accurate high performance thin layer chromatography method for simultaneous determination of withanolide A and bacoside A in combined dosage form. The stationary phase used was silica gel G60F(254). The mobile phase used was mixture of ethyl acetate: methanol: toluene: water (4:1:1:0.5 v/v/v/v). The detection of spots was carried out at 320 nm using absorbance reflectance mode. The method was validated in terms of linearity, accuracy, precision and specificity. The calibration curve was found to be linear between 200 to 800 ng/spot for withanolide A and 50 to 350 ng/spot for bacoside A. The limit of detection and limit of quantification for the withanolide A were found to be 3.05 and 10.06 ng/spot, respectively and for bacoside A 8.3 and 27.39 ng/spot, respectively. The proposed method can be successfully used to determine the drug content of marketed formulation. Medknow Publications & Media Pvt Ltd 2011 /pmc/articles/PMC3267314/ /pubmed/22303073 Text en Copyright: © Indian Journal of Pharmaceutical Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Short Communications
Shinde, P B
Aragade, P D
Agrawal, M R
Deokate, U A
Khadabadi, S S
Simultaneous Determination of Withanolide A and Bacoside A in Spansules by High-Performance Thin-Layer Chromatography
title Simultaneous Determination of Withanolide A and Bacoside A in Spansules by High-Performance Thin-Layer Chromatography
title_full Simultaneous Determination of Withanolide A and Bacoside A in Spansules by High-Performance Thin-Layer Chromatography
title_fullStr Simultaneous Determination of Withanolide A and Bacoside A in Spansules by High-Performance Thin-Layer Chromatography
title_full_unstemmed Simultaneous Determination of Withanolide A and Bacoside A in Spansules by High-Performance Thin-Layer Chromatography
title_short Simultaneous Determination of Withanolide A and Bacoside A in Spansules by High-Performance Thin-Layer Chromatography
title_sort simultaneous determination of withanolide a and bacoside a in spansules by high-performance thin-layer chromatography
topic Short Communications
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3267314/
https://www.ncbi.nlm.nih.gov/pubmed/22303073
work_keys_str_mv AT shindepb simultaneousdeterminationofwithanolideaandbacosideainspansulesbyhighperformancethinlayerchromatography
AT aragadepd simultaneousdeterminationofwithanolideaandbacosideainspansulesbyhighperformancethinlayerchromatography
AT agrawalmr simultaneousdeterminationofwithanolideaandbacosideainspansulesbyhighperformancethinlayerchromatography
AT deokateua simultaneousdeterminationofwithanolideaandbacosideainspansulesbyhighperformancethinlayerchromatography
AT khadabadiss simultaneousdeterminationofwithanolideaandbacosideainspansulesbyhighperformancethinlayerchromatography