Cargando…

The OnControl bone marrow biopsy technique is superior to the standard manual technique for hematologists-in-training: a prospective, randomized comparison

The purpose of this study was to compare a novel bone marrow device with the standard marrow needle in a prospective, randomized study in a teaching hospital employing hematologists-in-training. The new device, the OnControl Bone Marrow (OBM) Biopsy System, utilizes a battery-powered drill to insert...

Descripción completa

Detalles Bibliográficos
Autores principales: Reed, Louis Juden, Raghupathy, Radha, Strakhan, Marianna, Philbeck, Thomas E., Kim, Mimi Y., Battini, Ramakrishna, Hussain, Zulfiqar, Abdullah, Shaad, Schweber, Sarah, Bala, Kamalesh, Pacello, Thomas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: PAGEPress Publications 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3269796/
https://www.ncbi.nlm.nih.gov/pubmed/22593813
http://dx.doi.org/10.4081/hr.2011.e21
_version_ 1782222511812902912
author Reed, Louis Juden
Raghupathy, Radha
Strakhan, Marianna
Philbeck, Thomas E.
Kim, Mimi Y.
Battini, Ramakrishna
Hussain, Zulfiqar
Abdullah, Shaad
Schweber, Sarah
Bala, Kamalesh
Pacello, Thomas
author_facet Reed, Louis Juden
Raghupathy, Radha
Strakhan, Marianna
Philbeck, Thomas E.
Kim, Mimi Y.
Battini, Ramakrishna
Hussain, Zulfiqar
Abdullah, Shaad
Schweber, Sarah
Bala, Kamalesh
Pacello, Thomas
author_sort Reed, Louis Juden
collection PubMed
description The purpose of this study was to compare a novel bone marrow device with the standard marrow needle in a prospective, randomized study in a teaching hospital employing hematologists-in-training. The new device, the OnControl Bone Marrow (OBM) Biopsy System, utilizes a battery-powered drill to insert the needle. Fifty-four bone marrows (27 standard and 27 OBM) were performed by 11 fellows under the observation and supervision of 3 attending hematologists and 1 research technologist. The primary endpoint of the study, the mean length of the marrow biopsy specimens, a surrogate for marrow quality, was determined by a pathologist in a blinded manner. The mean length of the marrow biopsy specimens was significantly longer (56%) for the OBM group (15.3 mm) than for the standard bone marrow (SBM) group (9.8 mm), P<0.003. An objectively determined secondary endpoint; mean procedure time, skin-to-skin; also favored the OBM group (175 s) versus the SBM group (292 s), P<0.007. Several subjective secondary endpoints also favored the OBM group. Only minor adverse events were encountered in the OBM and SBM study groups. It was concluded that bone marrow procedures (BMPs) performed by hematologists-in-training were significantly faster and superior in quality when performed with the OBM compared to the SBM. These data suggest that the OBM may be considered a new standard of care for adult hematology patients. OBM also appears to be a superior method for training hematology fellows.
format Online
Article
Text
id pubmed-3269796
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher PAGEPress Publications
record_format MEDLINE/PubMed
spelling pubmed-32697962012-05-16 The OnControl bone marrow biopsy technique is superior to the standard manual technique for hematologists-in-training: a prospective, randomized comparison Reed, Louis Juden Raghupathy, Radha Strakhan, Marianna Philbeck, Thomas E. Kim, Mimi Y. Battini, Ramakrishna Hussain, Zulfiqar Abdullah, Shaad Schweber, Sarah Bala, Kamalesh Pacello, Thomas Hematol Rep Article The purpose of this study was to compare a novel bone marrow device with the standard marrow needle in a prospective, randomized study in a teaching hospital employing hematologists-in-training. The new device, the OnControl Bone Marrow (OBM) Biopsy System, utilizes a battery-powered drill to insert the needle. Fifty-four bone marrows (27 standard and 27 OBM) were performed by 11 fellows under the observation and supervision of 3 attending hematologists and 1 research technologist. The primary endpoint of the study, the mean length of the marrow biopsy specimens, a surrogate for marrow quality, was determined by a pathologist in a blinded manner. The mean length of the marrow biopsy specimens was significantly longer (56%) for the OBM group (15.3 mm) than for the standard bone marrow (SBM) group (9.8 mm), P<0.003. An objectively determined secondary endpoint; mean procedure time, skin-to-skin; also favored the OBM group (175 s) versus the SBM group (292 s), P<0.007. Several subjective secondary endpoints also favored the OBM group. Only minor adverse events were encountered in the OBM and SBM study groups. It was concluded that bone marrow procedures (BMPs) performed by hematologists-in-training were significantly faster and superior in quality when performed with the OBM compared to the SBM. These data suggest that the OBM may be considered a new standard of care for adult hematology patients. OBM also appears to be a superior method for training hematology fellows. PAGEPress Publications 2011-10-25 /pmc/articles/PMC3269796/ /pubmed/22593813 http://dx.doi.org/10.4081/hr.2011.e21 Text en ©Copyright L.J. Reed et al., 2011 This work is licensed under a Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0). Licensee PAGEPress, Italy
spellingShingle Article
Reed, Louis Juden
Raghupathy, Radha
Strakhan, Marianna
Philbeck, Thomas E.
Kim, Mimi Y.
Battini, Ramakrishna
Hussain, Zulfiqar
Abdullah, Shaad
Schweber, Sarah
Bala, Kamalesh
Pacello, Thomas
The OnControl bone marrow biopsy technique is superior to the standard manual technique for hematologists-in-training: a prospective, randomized comparison
title The OnControl bone marrow biopsy technique is superior to the standard manual technique for hematologists-in-training: a prospective, randomized comparison
title_full The OnControl bone marrow biopsy technique is superior to the standard manual technique for hematologists-in-training: a prospective, randomized comparison
title_fullStr The OnControl bone marrow biopsy technique is superior to the standard manual technique for hematologists-in-training: a prospective, randomized comparison
title_full_unstemmed The OnControl bone marrow biopsy technique is superior to the standard manual technique for hematologists-in-training: a prospective, randomized comparison
title_short The OnControl bone marrow biopsy technique is superior to the standard manual technique for hematologists-in-training: a prospective, randomized comparison
title_sort oncontrol bone marrow biopsy technique is superior to the standard manual technique for hematologists-in-training: a prospective, randomized comparison
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3269796/
https://www.ncbi.nlm.nih.gov/pubmed/22593813
http://dx.doi.org/10.4081/hr.2011.e21
work_keys_str_mv AT reedlouisjuden theoncontrolbonemarrowbiopsytechniqueissuperiortothestandardmanualtechniqueforhematologistsintrainingaprospectiverandomizedcomparison
AT raghupathyradha theoncontrolbonemarrowbiopsytechniqueissuperiortothestandardmanualtechniqueforhematologistsintrainingaprospectiverandomizedcomparison
AT strakhanmarianna theoncontrolbonemarrowbiopsytechniqueissuperiortothestandardmanualtechniqueforhematologistsintrainingaprospectiverandomizedcomparison
AT philbeckthomase theoncontrolbonemarrowbiopsytechniqueissuperiortothestandardmanualtechniqueforhematologistsintrainingaprospectiverandomizedcomparison
AT kimmimiy theoncontrolbonemarrowbiopsytechniqueissuperiortothestandardmanualtechniqueforhematologistsintrainingaprospectiverandomizedcomparison
AT battiniramakrishna theoncontrolbonemarrowbiopsytechniqueissuperiortothestandardmanualtechniqueforhematologistsintrainingaprospectiverandomizedcomparison
AT hussainzulfiqar theoncontrolbonemarrowbiopsytechniqueissuperiortothestandardmanualtechniqueforhematologistsintrainingaprospectiverandomizedcomparison
AT abdullahshaad theoncontrolbonemarrowbiopsytechniqueissuperiortothestandardmanualtechniqueforhematologistsintrainingaprospectiverandomizedcomparison
AT schwebersarah theoncontrolbonemarrowbiopsytechniqueissuperiortothestandardmanualtechniqueforhematologistsintrainingaprospectiverandomizedcomparison
AT balakamalesh theoncontrolbonemarrowbiopsytechniqueissuperiortothestandardmanualtechniqueforhematologistsintrainingaprospectiverandomizedcomparison
AT pacellothomas theoncontrolbonemarrowbiopsytechniqueissuperiortothestandardmanualtechniqueforhematologistsintrainingaprospectiverandomizedcomparison
AT reedlouisjuden oncontrolbonemarrowbiopsytechniqueissuperiortothestandardmanualtechniqueforhematologistsintrainingaprospectiverandomizedcomparison
AT raghupathyradha oncontrolbonemarrowbiopsytechniqueissuperiortothestandardmanualtechniqueforhematologistsintrainingaprospectiverandomizedcomparison
AT strakhanmarianna oncontrolbonemarrowbiopsytechniqueissuperiortothestandardmanualtechniqueforhematologistsintrainingaprospectiverandomizedcomparison
AT philbeckthomase oncontrolbonemarrowbiopsytechniqueissuperiortothestandardmanualtechniqueforhematologistsintrainingaprospectiverandomizedcomparison
AT kimmimiy oncontrolbonemarrowbiopsytechniqueissuperiortothestandardmanualtechniqueforhematologistsintrainingaprospectiverandomizedcomparison
AT battiniramakrishna oncontrolbonemarrowbiopsytechniqueissuperiortothestandardmanualtechniqueforhematologistsintrainingaprospectiverandomizedcomparison
AT hussainzulfiqar oncontrolbonemarrowbiopsytechniqueissuperiortothestandardmanualtechniqueforhematologistsintrainingaprospectiverandomizedcomparison
AT abdullahshaad oncontrolbonemarrowbiopsytechniqueissuperiortothestandardmanualtechniqueforhematologistsintrainingaprospectiverandomizedcomparison
AT schwebersarah oncontrolbonemarrowbiopsytechniqueissuperiortothestandardmanualtechniqueforhematologistsintrainingaprospectiverandomizedcomparison
AT balakamalesh oncontrolbonemarrowbiopsytechniqueissuperiortothestandardmanualtechniqueforhematologistsintrainingaprospectiverandomizedcomparison
AT pacellothomas oncontrolbonemarrowbiopsytechniqueissuperiortothestandardmanualtechniqueforhematologistsintrainingaprospectiverandomizedcomparison