Cargando…

Nonunited humerus shaft fractures treated by external fixator augmented by intramedullary rod

BACKGROUND: Nonunion of humeral shaft fractures after previously failed surgical treatment presents a challenging therapeutic problem especially in the presence of osteoporosis, bone defect, and joint stiffness. It would be beneficial to combine the use of external fixation technique and intramedull...

Descripción completa

Detalles Bibliográficos
Autor principal: El-Rosasy, Mahmoud A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3270607/
https://www.ncbi.nlm.nih.gov/pubmed/22345808
http://dx.doi.org/10.4103/0019-5413.91636
_version_ 1782222610444058624
author El-Rosasy, Mahmoud A
author_facet El-Rosasy, Mahmoud A
author_sort El-Rosasy, Mahmoud A
collection PubMed
description BACKGROUND: Nonunion of humeral shaft fractures after previously failed surgical treatment presents a challenging therapeutic problem especially in the presence of osteoporosis, bone defect, and joint stiffness. It would be beneficial to combine the use of external fixation technique and intramedullary rod in the treatment of such cases. The present study evaluates the results of using external fixator augmented by intramedullary rod and autogenous iliac crest bone grafting (ICBG) for the treatment of humerus shaft nonunion following previously failed surgical treatment. MATERIALS AND METHODS: Eighteen patients with atrophic nonunion of the humeral shaft following previous implant surgery with no active infection were included in the present study. The procedure included exploration of the nonunion, insertion of intramedullary rod (IM rod), autogenous ICBG and application of external fixator for compression. Ilizarov fixator was used in eight cases and monolateral fixator in ten cases. The monolateral fixator was preferred for females and obese patients to avoid abutment against the breast or chest wall following the use of Ilizarov fixator. The fixator was removed after clinical and radiological healing of the nonunion, but the IM rod was left indefinitely. The evaluation of results included both bone results (union rate, angular deformity and limb shortening) and functional outcome using the University of California, Los Angeles (UCLA) rating scale. RESULTS: The mean follow-up was 35 months (range 24 to 52 months). Bone union was obtained in all cases. The functional outcome was satisfactory in 15 cases (83%) and unsatisfactory in 3 cases (17%) due to joint stiffness. The time to bone healing averaged 4.2 months (range 3 to 7 months). The external fixator time averaged 4.5 months (range 3.2 to 8 months). Superficial pin tract infection occurred in 39% (28/72) of the pins. No cases of nerve palsy, refracture, or deep infection were encountered. CONCLUSION: The proposed technique is effective in treating humeral nonunion especially in the presence of osteoporosis and short bone segments. The inclusion of intramedullary rod as internal splint improves stability of fixation and prevents refracture after fixator removal.
format Online
Article
Text
id pubmed-3270607
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-32706072012-02-15 Nonunited humerus shaft fractures treated by external fixator augmented by intramedullary rod El-Rosasy, Mahmoud A Indian J Orthop Original Article BACKGROUND: Nonunion of humeral shaft fractures after previously failed surgical treatment presents a challenging therapeutic problem especially in the presence of osteoporosis, bone defect, and joint stiffness. It would be beneficial to combine the use of external fixation technique and intramedullary rod in the treatment of such cases. The present study evaluates the results of using external fixator augmented by intramedullary rod and autogenous iliac crest bone grafting (ICBG) for the treatment of humerus shaft nonunion following previously failed surgical treatment. MATERIALS AND METHODS: Eighteen patients with atrophic nonunion of the humeral shaft following previous implant surgery with no active infection were included in the present study. The procedure included exploration of the nonunion, insertion of intramedullary rod (IM rod), autogenous ICBG and application of external fixator for compression. Ilizarov fixator was used in eight cases and monolateral fixator in ten cases. The monolateral fixator was preferred for females and obese patients to avoid abutment against the breast or chest wall following the use of Ilizarov fixator. The fixator was removed after clinical and radiological healing of the nonunion, but the IM rod was left indefinitely. The evaluation of results included both bone results (union rate, angular deformity and limb shortening) and functional outcome using the University of California, Los Angeles (UCLA) rating scale. RESULTS: The mean follow-up was 35 months (range 24 to 52 months). Bone union was obtained in all cases. The functional outcome was satisfactory in 15 cases (83%) and unsatisfactory in 3 cases (17%) due to joint stiffness. The time to bone healing averaged 4.2 months (range 3 to 7 months). The external fixator time averaged 4.5 months (range 3.2 to 8 months). Superficial pin tract infection occurred in 39% (28/72) of the pins. No cases of nerve palsy, refracture, or deep infection were encountered. CONCLUSION: The proposed technique is effective in treating humeral nonunion especially in the presence of osteoporosis and short bone segments. The inclusion of intramedullary rod as internal splint improves stability of fixation and prevents refracture after fixator removal. Medknow Publications & Media Pvt Ltd 2012 /pmc/articles/PMC3270607/ /pubmed/22345808 http://dx.doi.org/10.4103/0019-5413.91636 Text en Copyright: © Indian Journal of Orthopaedics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
El-Rosasy, Mahmoud A
Nonunited humerus shaft fractures treated by external fixator augmented by intramedullary rod
title Nonunited humerus shaft fractures treated by external fixator augmented by intramedullary rod
title_full Nonunited humerus shaft fractures treated by external fixator augmented by intramedullary rod
title_fullStr Nonunited humerus shaft fractures treated by external fixator augmented by intramedullary rod
title_full_unstemmed Nonunited humerus shaft fractures treated by external fixator augmented by intramedullary rod
title_short Nonunited humerus shaft fractures treated by external fixator augmented by intramedullary rod
title_sort nonunited humerus shaft fractures treated by external fixator augmented by intramedullary rod
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3270607/
https://www.ncbi.nlm.nih.gov/pubmed/22345808
http://dx.doi.org/10.4103/0019-5413.91636
work_keys_str_mv AT elrosasymahmouda nonunitedhumerusshaftfracturestreatedbyexternalfixatoraugmentedbyintramedullaryrod