Cargando…
Evidence Based Development of a Novel Lateral Fibula Plate (VariAx Fibula) Using a Real CT Bone Data Based Optimization Process During Device Development
Development of novel implants in orthopaedic trauma surgery is based on limited datasets of cadaver trials or artificial bone models. A method has been developed whereby implants can be constructed in an evidence based method founded on a large anatomic database consisting of more than 2.000 dataset...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Bentham Open
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3271305/ https://www.ncbi.nlm.nih.gov/pubmed/22312417 http://dx.doi.org/10.2174/1874325001206010001 |
_version_ | 1782222683920924672 |
---|---|
author | Schulz, Arndt P Reimers, Nils Wipf, Felix Vallotton, Michel Bonaretti, Serena Kozic, Nina Reyes, Mauricio Kienast, Benjamin J |
author_facet | Schulz, Arndt P Reimers, Nils Wipf, Felix Vallotton, Michel Bonaretti, Serena Kozic, Nina Reyes, Mauricio Kienast, Benjamin J |
author_sort | Schulz, Arndt P |
collection | PubMed |
description | Development of novel implants in orthopaedic trauma surgery is based on limited datasets of cadaver trials or artificial bone models. A method has been developed whereby implants can be constructed in an evidence based method founded on a large anatomic database consisting of more than 2.000 datasets of bones extracted from CT scans. The aim of this study was the development and clinical application of an anatomically pre-contoured plate for the treatment of distal fibular fractures based on the anatomical database. 48 Caucasian and Asian bone models (left and right) from the database were used for the preliminary optimization process and validation of the fibula plate. The implant was constructed to fit bilaterally in a lateral position of the fibula. Then a biomechanical comparison of the designed implant to the current gold standard in the treatment of distal fibular fractures (locking 1/3 tubular plate) was conducted. Finally, a clinical surveillance study to evaluate the grade of implant fit achieved was performed. The results showed that with a virtual anatomic database it was possible to design a fibula plate with an optimized fit for a large proportion of the population. Biomechanical testing showed the novel fibula plate to be superior to 1/3 tubular plates in 4-point bending tests. The clinical application showed a very high degree of primary implant fit. Only in a small minority of cases further intra-operative implant bending was necessary. Therefore, the goal to develop an implant for the treatment of distal fibular fractures based on the evidence of a large anatomical database could be attained. Biomechanical testing showed good results regarding the stability and the clinical application confirmed the high grade of anatomical fit. |
format | Online Article Text |
id | pubmed-3271305 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Bentham Open |
record_format | MEDLINE/PubMed |
spelling | pubmed-32713052012-02-06 Evidence Based Development of a Novel Lateral Fibula Plate (VariAx Fibula) Using a Real CT Bone Data Based Optimization Process During Device Development Schulz, Arndt P Reimers, Nils Wipf, Felix Vallotton, Michel Bonaretti, Serena Kozic, Nina Reyes, Mauricio Kienast, Benjamin J Open Orthop J Article Development of novel implants in orthopaedic trauma surgery is based on limited datasets of cadaver trials or artificial bone models. A method has been developed whereby implants can be constructed in an evidence based method founded on a large anatomic database consisting of more than 2.000 datasets of bones extracted from CT scans. The aim of this study was the development and clinical application of an anatomically pre-contoured plate for the treatment of distal fibular fractures based on the anatomical database. 48 Caucasian and Asian bone models (left and right) from the database were used for the preliminary optimization process and validation of the fibula plate. The implant was constructed to fit bilaterally in a lateral position of the fibula. Then a biomechanical comparison of the designed implant to the current gold standard in the treatment of distal fibular fractures (locking 1/3 tubular plate) was conducted. Finally, a clinical surveillance study to evaluate the grade of implant fit achieved was performed. The results showed that with a virtual anatomic database it was possible to design a fibula plate with an optimized fit for a large proportion of the population. Biomechanical testing showed the novel fibula plate to be superior to 1/3 tubular plates in 4-point bending tests. The clinical application showed a very high degree of primary implant fit. Only in a small minority of cases further intra-operative implant bending was necessary. Therefore, the goal to develop an implant for the treatment of distal fibular fractures based on the evidence of a large anatomical database could be attained. Biomechanical testing showed good results regarding the stability and the clinical application confirmed the high grade of anatomical fit. Bentham Open 2012-01-19 /pmc/articles/PMC3271305/ /pubmed/22312417 http://dx.doi.org/10.2174/1874325001206010001 Text en © Schulz et al.; Licensee Bentham Open. http://creativecommons.org/licenses/by-nc/3.0/ This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited. |
spellingShingle | Article Schulz, Arndt P Reimers, Nils Wipf, Felix Vallotton, Michel Bonaretti, Serena Kozic, Nina Reyes, Mauricio Kienast, Benjamin J Evidence Based Development of a Novel Lateral Fibula Plate (VariAx Fibula) Using a Real CT Bone Data Based Optimization Process During Device Development |
title | Evidence Based Development of a Novel Lateral Fibula Plate (VariAx Fibula) Using a Real CT Bone Data Based Optimization Process During Device Development |
title_full | Evidence Based Development of a Novel Lateral Fibula Plate (VariAx Fibula) Using a Real CT Bone Data Based Optimization Process During Device Development |
title_fullStr | Evidence Based Development of a Novel Lateral Fibula Plate (VariAx Fibula) Using a Real CT Bone Data Based Optimization Process During Device Development |
title_full_unstemmed | Evidence Based Development of a Novel Lateral Fibula Plate (VariAx Fibula) Using a Real CT Bone Data Based Optimization Process During Device Development |
title_short | Evidence Based Development of a Novel Lateral Fibula Plate (VariAx Fibula) Using a Real CT Bone Data Based Optimization Process During Device Development |
title_sort | evidence based development of a novel lateral fibula plate (variax fibula) using a real ct bone data based optimization process during device development |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3271305/ https://www.ncbi.nlm.nih.gov/pubmed/22312417 http://dx.doi.org/10.2174/1874325001206010001 |
work_keys_str_mv | AT schulzarndtp evidencebaseddevelopmentofanovellateralfibulaplatevariaxfibulausingarealctbonedatabasedoptimizationprocessduringdevicedevelopment AT reimersnils evidencebaseddevelopmentofanovellateralfibulaplatevariaxfibulausingarealctbonedatabasedoptimizationprocessduringdevicedevelopment AT wipffelix evidencebaseddevelopmentofanovellateralfibulaplatevariaxfibulausingarealctbonedatabasedoptimizationprocessduringdevicedevelopment AT vallottonmichel evidencebaseddevelopmentofanovellateralfibulaplatevariaxfibulausingarealctbonedatabasedoptimizationprocessduringdevicedevelopment AT bonarettiserena evidencebaseddevelopmentofanovellateralfibulaplatevariaxfibulausingarealctbonedatabasedoptimizationprocessduringdevicedevelopment AT kozicnina evidencebaseddevelopmentofanovellateralfibulaplatevariaxfibulausingarealctbonedatabasedoptimizationprocessduringdevicedevelopment AT reyesmauricio evidencebaseddevelopmentofanovellateralfibulaplatevariaxfibulausingarealctbonedatabasedoptimizationprocessduringdevicedevelopment AT kienastbenjaminj evidencebaseddevelopmentofanovellateralfibulaplatevariaxfibulausingarealctbonedatabasedoptimizationprocessduringdevicedevelopment |