Cargando…

An alternative subcoronary implantation technique decreases the risk of complete heart block after stentless aortic valve replacement

CONTEXT: Stentless aortic valve prostheses have excellent hemodynamic profiles, but may be associated with an increased postoperative heart block when compared to conventional prostheses. AIMS: To assess the effect of an alternative subcoronary implantation technique on postoperative complete heart...

Descripción completa

Detalles Bibliográficos
Autores principales: Song, Zhigang, Lehr, Eric J., Wang, Shaohua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3271683/
https://www.ncbi.nlm.nih.gov/pubmed/22346147
http://dx.doi.org/10.4103/0975-3583.91594
_version_ 1782222747799126016
author Song, Zhigang
Lehr, Eric J.
Wang, Shaohua
author_facet Song, Zhigang
Lehr, Eric J.
Wang, Shaohua
author_sort Song, Zhigang
collection PubMed
description CONTEXT: Stentless aortic valve prostheses have excellent hemodynamic profiles, but may be associated with an increased postoperative heart block when compared to conventional prostheses. AIMS: To assess the effect of an alternative subcoronary implantation technique on postoperative complete heart block (CHB) and permanent pacemaker implantation (PPI) following aortic valve replacement (AVR) with stentless tissue valves. SETTINGS AND DESIGN: A total of 130 consecutive patients undergoing AVR with stentless tissue valves by a single surgeon were studied retrospectively. MATERIALS AND METHODS: A stentless tissue valve was implanted into 80 patients using the conventional modified subcoronary implantation technique, and 50 patients received a stentless tissue valve by an alternative subcoronary technique in which the inflow suture line is raised at the level of right-non coronary commissure. Data were collected at the time of hospital discharge and at 6–12 months postoperatively. STATISTICAL ANALYSIS USED: Independent samples t-test was used to compare continuous variables, and categorical variables were compared with the chi-square test. RESULTS: Use of this new method reduced postoperative CHB (4.0% vs. 16.3%, P = 0.033), with fewer patients requiring PPI in the early postoperative period (6.0% vs. 18.8%, P = 0.041). Echocardiographic examination showed no differences in the effective orifice area, peak and mean aortic valve gradients, or left ventricular mass index between groups. Trivial or mild aortic regurgitation was found in 3.9% of patients with the conventional modified technique and 4.0% of patients undergoing the alternative technique, during follow-up (P > 0.05). CONCLUSIONS: Compared to the conventional subcoronary implantation technique, the alternative subcoronary implantation technique reduces the incidence of new CHB and the requirement of PPI following AVR with stentless tissue valves while preserving mid-term hemodynamic function.
format Online
Article
Text
id pubmed-3271683
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-32716832012-02-15 An alternative subcoronary implantation technique decreases the risk of complete heart block after stentless aortic valve replacement Song, Zhigang Lehr, Eric J. Wang, Shaohua J Cardiovasc Dis Res Cardiothoracic Surgery CONTEXT: Stentless aortic valve prostheses have excellent hemodynamic profiles, but may be associated with an increased postoperative heart block when compared to conventional prostheses. AIMS: To assess the effect of an alternative subcoronary implantation technique on postoperative complete heart block (CHB) and permanent pacemaker implantation (PPI) following aortic valve replacement (AVR) with stentless tissue valves. SETTINGS AND DESIGN: A total of 130 consecutive patients undergoing AVR with stentless tissue valves by a single surgeon were studied retrospectively. MATERIALS AND METHODS: A stentless tissue valve was implanted into 80 patients using the conventional modified subcoronary implantation technique, and 50 patients received a stentless tissue valve by an alternative subcoronary technique in which the inflow suture line is raised at the level of right-non coronary commissure. Data were collected at the time of hospital discharge and at 6–12 months postoperatively. STATISTICAL ANALYSIS USED: Independent samples t-test was used to compare continuous variables, and categorical variables were compared with the chi-square test. RESULTS: Use of this new method reduced postoperative CHB (4.0% vs. 16.3%, P = 0.033), with fewer patients requiring PPI in the early postoperative period (6.0% vs. 18.8%, P = 0.041). Echocardiographic examination showed no differences in the effective orifice area, peak and mean aortic valve gradients, or left ventricular mass index between groups. Trivial or mild aortic regurgitation was found in 3.9% of patients with the conventional modified technique and 4.0% of patients undergoing the alternative technique, during follow-up (P > 0.05). CONCLUSIONS: Compared to the conventional subcoronary implantation technique, the alternative subcoronary implantation technique reduces the incidence of new CHB and the requirement of PPI following AVR with stentless tissue valves while preserving mid-term hemodynamic function. Medknow Publications & Media Pvt Ltd 2012 /pmc/articles/PMC3271683/ /pubmed/22346147 http://dx.doi.org/10.4103/0975-3583.91594 Text en Copyright: © Journal of Cardiovascular Disease Research http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Cardiothoracic Surgery
Song, Zhigang
Lehr, Eric J.
Wang, Shaohua
An alternative subcoronary implantation technique decreases the risk of complete heart block after stentless aortic valve replacement
title An alternative subcoronary implantation technique decreases the risk of complete heart block after stentless aortic valve replacement
title_full An alternative subcoronary implantation technique decreases the risk of complete heart block after stentless aortic valve replacement
title_fullStr An alternative subcoronary implantation technique decreases the risk of complete heart block after stentless aortic valve replacement
title_full_unstemmed An alternative subcoronary implantation technique decreases the risk of complete heart block after stentless aortic valve replacement
title_short An alternative subcoronary implantation technique decreases the risk of complete heart block after stentless aortic valve replacement
title_sort alternative subcoronary implantation technique decreases the risk of complete heart block after stentless aortic valve replacement
topic Cardiothoracic Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3271683/
https://www.ncbi.nlm.nih.gov/pubmed/22346147
http://dx.doi.org/10.4103/0975-3583.91594
work_keys_str_mv AT songzhigang analternativesubcoronaryimplantationtechniquedecreasestheriskofcompleteheartblockafterstentlessaorticvalvereplacement
AT lehrericj analternativesubcoronaryimplantationtechniquedecreasestheriskofcompleteheartblockafterstentlessaorticvalvereplacement
AT wangshaohua analternativesubcoronaryimplantationtechniquedecreasestheriskofcompleteheartblockafterstentlessaorticvalvereplacement
AT songzhigang alternativesubcoronaryimplantationtechniquedecreasestheriskofcompleteheartblockafterstentlessaorticvalvereplacement
AT lehrericj alternativesubcoronaryimplantationtechniquedecreasestheriskofcompleteheartblockafterstentlessaorticvalvereplacement
AT wangshaohua alternativesubcoronaryimplantationtechniquedecreasestheriskofcompleteheartblockafterstentlessaorticvalvereplacement