The role of perfusion CT in identifying stroke mimics in the emergency room: a case of status epilepticus presenting with perfusion CT alterations
Emergency medicine physicians are often faced with the challenging task of differentiating true acute ischemic strokes from stroke mimics. We present a case that was initially diagnosed as acute stroke. However, perfusion CT and EEG eventually led to the final diagnosis of status epilepticus. This c...
Autores principales: | Guerrero, Waldo R, Dababneh, Haitham, Eisenschenk, Stephan |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3271969/ https://www.ncbi.nlm.nih.gov/pubmed/22264341 http://dx.doi.org/10.1186/1865-1380-5-4 |
Ejemplares similares
-
Telestroke Assessment With Perfusion CT Improves the Diagnostic Accuracy of Stroke vs. Mimic
por: Tran, Lucinda, et al.
Publicado: (2021) -
CT perfusion in acute stroke
por: Khandelwal, Niranjan
Publicado: (2008) -
CT perfusion: stroke, seizure or both?
por: Davis, Elizabeth, et al.
Publicado: (2021) -
Seizure Mimicking Stroke: Role of CT Perfusion
por: Hedna, Vishnumurthy Shushrutha, et al.
Publicado: (2012) -
Dynamic CT but Not Optimized Multiphase CT Angiography Accurately Identifies CT Perfusion Target Mismatch Ischemic Stroke Patients
por: Tian, Huiqiao, et al.
Publicado: (2019)