Cargando…
Acute Beneficial Hemodynamic Effects of a Novel 3D-Echocardiographic Optimization Protocol in Cardiac Resynchronization Therapy
BACKGROUND: Post-implantation therapies to optimize cardiac resynchronization therapy (CRT) focus on adjustments of the atrio-ventricular (AV) delay and ventricular-to-ventricular (VV) interval. However, there is little consensus on how to achieve best resynchronization with these parameters. The ai...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3272028/ https://www.ncbi.nlm.nih.gov/pubmed/22319598 http://dx.doi.org/10.1371/journal.pone.0030964 |
_version_ | 1782222777895354368 |
---|---|
author | Sonne, Carolin Bott-Flügel, Lorenz Hauck, Simon Lesevic, Hasema Barthel, Petra Michalk, Fabian Hoppe, Katharina Hausleiter, Jörg Schömig, Albert Kolb, Christof |
author_facet | Sonne, Carolin Bott-Flügel, Lorenz Hauck, Simon Lesevic, Hasema Barthel, Petra Michalk, Fabian Hoppe, Katharina Hausleiter, Jörg Schömig, Albert Kolb, Christof |
author_sort | Sonne, Carolin |
collection | PubMed |
description | BACKGROUND: Post-implantation therapies to optimize cardiac resynchronization therapy (CRT) focus on adjustments of the atrio-ventricular (AV) delay and ventricular-to-ventricular (VV) interval. However, there is little consensus on how to achieve best resynchronization with these parameters. The aim of this study was to examine a novel combination of doppler echocardiography (DE) and three-dimensional echocardiography (3DE) for individualized optimization of device based AV delays and VV intervals compared to empiric programming. METHODS: 25 recipients of CRT (male: 56%, mean age: 67 years) were included in this study. Ejection fraction (EF), the primary outcome parameter, and left ventricular (LV) dimensions were evaluated by 3DE before CRT (baseline), after AV delay optimization while pacing the ventricles simultaneously (empiric VV interval programming) and after individualized VV interval optimization. For AV delay optimization aortic velocity time integral (AoVTI) was examined in eight different AV delays, and the AV delay with the highest AoVTI was programmed. For individualized VV interval optimization 3DE full-volume datasets of the left ventricle were obtained and analyzed to derive a systolic dyssynchrony index (SDI), calculated from the dispersion of time to minimal regional volume for all 16 LV segments. Consecutively, SDI was evaluated in six different VV intervals (including LV or right ventricular preactivation), and the VV interval with the lowest SDI was programmed (individualized optimization). RESULTS: EF increased from baseline 23±7% to 30±8 (p<0.001) after AV delay optimization and to 32±8% (p<0.05) after individualized optimization with an associated decrease of end-systolic volume from a baseline of 138±60 ml to 115±42 ml (p<0.001). Moreover, individualized optimization significantly reduced SDI from a baseline of 14.3±5.5% to 6.1±2.6% (p<0.001). CONCLUSIONS: Compared with empiric programming of biventricular pacemakers, individualized echocardiographic optimization with the integration of 3-dimensional indices into the optimization protocol acutely improved LV systolic function and decreased ESV and can be used to select the optimal AV delay and VV interval in CRT. |
format | Online Article Text |
id | pubmed-3272028 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-32720282012-02-08 Acute Beneficial Hemodynamic Effects of a Novel 3D-Echocardiographic Optimization Protocol in Cardiac Resynchronization Therapy Sonne, Carolin Bott-Flügel, Lorenz Hauck, Simon Lesevic, Hasema Barthel, Petra Michalk, Fabian Hoppe, Katharina Hausleiter, Jörg Schömig, Albert Kolb, Christof PLoS One Research Article BACKGROUND: Post-implantation therapies to optimize cardiac resynchronization therapy (CRT) focus on adjustments of the atrio-ventricular (AV) delay and ventricular-to-ventricular (VV) interval. However, there is little consensus on how to achieve best resynchronization with these parameters. The aim of this study was to examine a novel combination of doppler echocardiography (DE) and three-dimensional echocardiography (3DE) for individualized optimization of device based AV delays and VV intervals compared to empiric programming. METHODS: 25 recipients of CRT (male: 56%, mean age: 67 years) were included in this study. Ejection fraction (EF), the primary outcome parameter, and left ventricular (LV) dimensions were evaluated by 3DE before CRT (baseline), after AV delay optimization while pacing the ventricles simultaneously (empiric VV interval programming) and after individualized VV interval optimization. For AV delay optimization aortic velocity time integral (AoVTI) was examined in eight different AV delays, and the AV delay with the highest AoVTI was programmed. For individualized VV interval optimization 3DE full-volume datasets of the left ventricle were obtained and analyzed to derive a systolic dyssynchrony index (SDI), calculated from the dispersion of time to minimal regional volume for all 16 LV segments. Consecutively, SDI was evaluated in six different VV intervals (including LV or right ventricular preactivation), and the VV interval with the lowest SDI was programmed (individualized optimization). RESULTS: EF increased from baseline 23±7% to 30±8 (p<0.001) after AV delay optimization and to 32±8% (p<0.05) after individualized optimization with an associated decrease of end-systolic volume from a baseline of 138±60 ml to 115±42 ml (p<0.001). Moreover, individualized optimization significantly reduced SDI from a baseline of 14.3±5.5% to 6.1±2.6% (p<0.001). CONCLUSIONS: Compared with empiric programming of biventricular pacemakers, individualized echocardiographic optimization with the integration of 3-dimensional indices into the optimization protocol acutely improved LV systolic function and decreased ESV and can be used to select the optimal AV delay and VV interval in CRT. Public Library of Science 2012-02-03 /pmc/articles/PMC3272028/ /pubmed/22319598 http://dx.doi.org/10.1371/journal.pone.0030964 Text en Sonne et al. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Sonne, Carolin Bott-Flügel, Lorenz Hauck, Simon Lesevic, Hasema Barthel, Petra Michalk, Fabian Hoppe, Katharina Hausleiter, Jörg Schömig, Albert Kolb, Christof Acute Beneficial Hemodynamic Effects of a Novel 3D-Echocardiographic Optimization Protocol in Cardiac Resynchronization Therapy |
title | Acute Beneficial Hemodynamic Effects of a Novel 3D-Echocardiographic Optimization Protocol in Cardiac Resynchronization Therapy |
title_full | Acute Beneficial Hemodynamic Effects of a Novel 3D-Echocardiographic Optimization Protocol in Cardiac Resynchronization Therapy |
title_fullStr | Acute Beneficial Hemodynamic Effects of a Novel 3D-Echocardiographic Optimization Protocol in Cardiac Resynchronization Therapy |
title_full_unstemmed | Acute Beneficial Hemodynamic Effects of a Novel 3D-Echocardiographic Optimization Protocol in Cardiac Resynchronization Therapy |
title_short | Acute Beneficial Hemodynamic Effects of a Novel 3D-Echocardiographic Optimization Protocol in Cardiac Resynchronization Therapy |
title_sort | acute beneficial hemodynamic effects of a novel 3d-echocardiographic optimization protocol in cardiac resynchronization therapy |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3272028/ https://www.ncbi.nlm.nih.gov/pubmed/22319598 http://dx.doi.org/10.1371/journal.pone.0030964 |
work_keys_str_mv | AT sonnecarolin acutebeneficialhemodynamiceffectsofanovel3dechocardiographicoptimizationprotocolincardiacresynchronizationtherapy AT bottflugellorenz acutebeneficialhemodynamiceffectsofanovel3dechocardiographicoptimizationprotocolincardiacresynchronizationtherapy AT haucksimon acutebeneficialhemodynamiceffectsofanovel3dechocardiographicoptimizationprotocolincardiacresynchronizationtherapy AT lesevichasema acutebeneficialhemodynamiceffectsofanovel3dechocardiographicoptimizationprotocolincardiacresynchronizationtherapy AT barthelpetra acutebeneficialhemodynamiceffectsofanovel3dechocardiographicoptimizationprotocolincardiacresynchronizationtherapy AT michalkfabian acutebeneficialhemodynamiceffectsofanovel3dechocardiographicoptimizationprotocolincardiacresynchronizationtherapy AT hoppekatharina acutebeneficialhemodynamiceffectsofanovel3dechocardiographicoptimizationprotocolincardiacresynchronizationtherapy AT hausleiterjorg acutebeneficialhemodynamiceffectsofanovel3dechocardiographicoptimizationprotocolincardiacresynchronizationtherapy AT schomigalbert acutebeneficialhemodynamiceffectsofanovel3dechocardiographicoptimizationprotocolincardiacresynchronizationtherapy AT kolbchristof acutebeneficialhemodynamiceffectsofanovel3dechocardiographicoptimizationprotocolincardiacresynchronizationtherapy |