Cargando…

Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device

To measure precise blood pressure (BP) and pulse rate without using a cuff, we have developed an arterial pulsimeter consisting of a small, portable apparatus incorporating a Hall device. Regression analysis of the pulse wave measured during testing of the arterial pulsimeter was conducted using two...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Sang-Suk, Nam, Dong-Hyun, Hong, You-Sik, Lee, Woo-Beom, Son, Il-Ho, Kim, Keun-Ho, Choi, Jong-Gu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3274031/
https://www.ncbi.nlm.nih.gov/pubmed/22319381
http://dx.doi.org/10.3390/s110201784
_version_ 1782222994942197760
author Lee, Sang-Suk
Nam, Dong-Hyun
Hong, You-Sik
Lee, Woo-Beom
Son, Il-Ho
Kim, Keun-Ho
Choi, Jong-Gu
author_facet Lee, Sang-Suk
Nam, Dong-Hyun
Hong, You-Sik
Lee, Woo-Beom
Son, Il-Ho
Kim, Keun-Ho
Choi, Jong-Gu
author_sort Lee, Sang-Suk
collection PubMed
description To measure precise blood pressure (BP) and pulse rate without using a cuff, we have developed an arterial pulsimeter consisting of a small, portable apparatus incorporating a Hall device. Regression analysis of the pulse wave measured during testing of the arterial pulsimeter was conducted using two equations of the BP algorithm. The estimated values of BP obtained by the cuffless arterial pulsimeter over 5 s were compared with values obtained using electronic or liquid mercury BP meters. The standard deviation between the estimated values and the measured values for systolic and diastolic BP were 8.3 and 4.9, respectively, which are close to the range of values of the BP International Standard. Detailed analysis of the pulse wave measured by the cuffless radial artery pulsimeter by detecting changes in the magnetic field can be used to develop a new diagnostic algorithm for BP, which can be applied to new medical apparatus such as the radial artery pulsimeter.
format Online
Article
Text
id pubmed-3274031
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-32740312012-02-08 Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device Lee, Sang-Suk Nam, Dong-Hyun Hong, You-Sik Lee, Woo-Beom Son, Il-Ho Kim, Keun-Ho Choi, Jong-Gu Sensors (Basel) Article To measure precise blood pressure (BP) and pulse rate without using a cuff, we have developed an arterial pulsimeter consisting of a small, portable apparatus incorporating a Hall device. Regression analysis of the pulse wave measured during testing of the arterial pulsimeter was conducted using two equations of the BP algorithm. The estimated values of BP obtained by the cuffless arterial pulsimeter over 5 s were compared with values obtained using electronic or liquid mercury BP meters. The standard deviation between the estimated values and the measured values for systolic and diastolic BP were 8.3 and 4.9, respectively, which are close to the range of values of the BP International Standard. Detailed analysis of the pulse wave measured by the cuffless radial artery pulsimeter by detecting changes in the magnetic field can be used to develop a new diagnostic algorithm for BP, which can be applied to new medical apparatus such as the radial artery pulsimeter. Molecular Diversity Preservation International (MDPI) 2011-01-31 /pmc/articles/PMC3274031/ /pubmed/22319381 http://dx.doi.org/10.3390/s110201784 Text en © 2011 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Lee, Sang-Suk
Nam, Dong-Hyun
Hong, You-Sik
Lee, Woo-Beom
Son, Il-Ho
Kim, Keun-Ho
Choi, Jong-Gu
Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device
title Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device
title_full Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device
title_fullStr Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device
title_full_unstemmed Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device
title_short Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device
title_sort measurement of blood pressure using an arterial pulsimeter equipped with a hall device
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3274031/
https://www.ncbi.nlm.nih.gov/pubmed/22319381
http://dx.doi.org/10.3390/s110201784
work_keys_str_mv AT leesangsuk measurementofbloodpressureusinganarterialpulsimeterequippedwithahalldevice
AT namdonghyun measurementofbloodpressureusinganarterialpulsimeterequippedwithahalldevice
AT hongyousik measurementofbloodpressureusinganarterialpulsimeterequippedwithahalldevice
AT leewoobeom measurementofbloodpressureusinganarterialpulsimeterequippedwithahalldevice
AT sonilho measurementofbloodpressureusinganarterialpulsimeterequippedwithahalldevice
AT kimkeunho measurementofbloodpressureusinganarterialpulsimeterequippedwithahalldevice
AT choijonggu measurementofbloodpressureusinganarterialpulsimeterequippedwithahalldevice