Cargando…
Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device
To measure precise blood pressure (BP) and pulse rate without using a cuff, we have developed an arterial pulsimeter consisting of a small, portable apparatus incorporating a Hall device. Regression analysis of the pulse wave measured during testing of the arterial pulsimeter was conducted using two...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3274031/ https://www.ncbi.nlm.nih.gov/pubmed/22319381 http://dx.doi.org/10.3390/s110201784 |
_version_ | 1782222994942197760 |
---|---|
author | Lee, Sang-Suk Nam, Dong-Hyun Hong, You-Sik Lee, Woo-Beom Son, Il-Ho Kim, Keun-Ho Choi, Jong-Gu |
author_facet | Lee, Sang-Suk Nam, Dong-Hyun Hong, You-Sik Lee, Woo-Beom Son, Il-Ho Kim, Keun-Ho Choi, Jong-Gu |
author_sort | Lee, Sang-Suk |
collection | PubMed |
description | To measure precise blood pressure (BP) and pulse rate without using a cuff, we have developed an arterial pulsimeter consisting of a small, portable apparatus incorporating a Hall device. Regression analysis of the pulse wave measured during testing of the arterial pulsimeter was conducted using two equations of the BP algorithm. The estimated values of BP obtained by the cuffless arterial pulsimeter over 5 s were compared with values obtained using electronic or liquid mercury BP meters. The standard deviation between the estimated values and the measured values for systolic and diastolic BP were 8.3 and 4.9, respectively, which are close to the range of values of the BP International Standard. Detailed analysis of the pulse wave measured by the cuffless radial artery pulsimeter by detecting changes in the magnetic field can be used to develop a new diagnostic algorithm for BP, which can be applied to new medical apparatus such as the radial artery pulsimeter. |
format | Online Article Text |
id | pubmed-3274031 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-32740312012-02-08 Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device Lee, Sang-Suk Nam, Dong-Hyun Hong, You-Sik Lee, Woo-Beom Son, Il-Ho Kim, Keun-Ho Choi, Jong-Gu Sensors (Basel) Article To measure precise blood pressure (BP) and pulse rate without using a cuff, we have developed an arterial pulsimeter consisting of a small, portable apparatus incorporating a Hall device. Regression analysis of the pulse wave measured during testing of the arterial pulsimeter was conducted using two equations of the BP algorithm. The estimated values of BP obtained by the cuffless arterial pulsimeter over 5 s were compared with values obtained using electronic or liquid mercury BP meters. The standard deviation between the estimated values and the measured values for systolic and diastolic BP were 8.3 and 4.9, respectively, which are close to the range of values of the BP International Standard. Detailed analysis of the pulse wave measured by the cuffless radial artery pulsimeter by detecting changes in the magnetic field can be used to develop a new diagnostic algorithm for BP, which can be applied to new medical apparatus such as the radial artery pulsimeter. Molecular Diversity Preservation International (MDPI) 2011-01-31 /pmc/articles/PMC3274031/ /pubmed/22319381 http://dx.doi.org/10.3390/s110201784 Text en © 2011 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Lee, Sang-Suk Nam, Dong-Hyun Hong, You-Sik Lee, Woo-Beom Son, Il-Ho Kim, Keun-Ho Choi, Jong-Gu Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device |
title | Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device |
title_full | Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device |
title_fullStr | Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device |
title_full_unstemmed | Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device |
title_short | Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device |
title_sort | measurement of blood pressure using an arterial pulsimeter equipped with a hall device |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3274031/ https://www.ncbi.nlm.nih.gov/pubmed/22319381 http://dx.doi.org/10.3390/s110201784 |
work_keys_str_mv | AT leesangsuk measurementofbloodpressureusinganarterialpulsimeterequippedwithahalldevice AT namdonghyun measurementofbloodpressureusinganarterialpulsimeterequippedwithahalldevice AT hongyousik measurementofbloodpressureusinganarterialpulsimeterequippedwithahalldevice AT leewoobeom measurementofbloodpressureusinganarterialpulsimeterequippedwithahalldevice AT sonilho measurementofbloodpressureusinganarterialpulsimeterequippedwithahalldevice AT kimkeunho measurementofbloodpressureusinganarterialpulsimeterequippedwithahalldevice AT choijonggu measurementofbloodpressureusinganarterialpulsimeterequippedwithahalldevice |