Cargando…

Fundamentals of in Situ Digital Camera Methodology for Water Quality Monitoring of Coast and Ocean

Conventional digital cameras, the Nikon Coolpix885(®) and the SeaLife ECOshot(®), were used as in situ optical instruments for water quality monitoring. Measured response spectra showed that these digital cameras are basically three-band radiometers. The response values in the red, green and blue ba...

Descripción completa

Detalles Bibliográficos
Autores principales: Goddijn-Murphy, Lonneke, Dailloux, Damien, White, Martin, Bowers, Dave
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3274132/
https://www.ncbi.nlm.nih.gov/pubmed/22346729
http://dx.doi.org/10.3390/s90705825
_version_ 1782223018145087488
author Goddijn-Murphy, Lonneke
Dailloux, Damien
White, Martin
Bowers, Dave
author_facet Goddijn-Murphy, Lonneke
Dailloux, Damien
White, Martin
Bowers, Dave
author_sort Goddijn-Murphy, Lonneke
collection PubMed
description Conventional digital cameras, the Nikon Coolpix885(®) and the SeaLife ECOshot(®), were used as in situ optical instruments for water quality monitoring. Measured response spectra showed that these digital cameras are basically three-band radiometers. The response values in the red, green and blue bands, quantified by RGB values of digital images of the water surface, were comparable to measurements of irradiance levels at red, green and cyan/blue wavelengths of water leaving light. Different systems were deployed to capture upwelling light from below the surface, while eliminating direct surface reflection. Relationships between RGB ratios of water surface images, and water quality parameters were found to be consistent with previous measurements using more traditional narrow-band radiometers. This current paper focuses on the method that was used to acquire digital images, derive RGB values and relate measurements to water quality parameters. Field measurements were obtained in Galway Bay, Ireland, and in the Southern Rockall Trough in the North Atlantic, where both yellow substance and chlorophyll concentrations were successfully assessed using the digital camera method.
format Online
Article
Text
id pubmed-3274132
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-32741322012-02-15 Fundamentals of in Situ Digital Camera Methodology for Water Quality Monitoring of Coast and Ocean Goddijn-Murphy, Lonneke Dailloux, Damien White, Martin Bowers, Dave Sensors (Basel) Article Conventional digital cameras, the Nikon Coolpix885(®) and the SeaLife ECOshot(®), were used as in situ optical instruments for water quality monitoring. Measured response spectra showed that these digital cameras are basically three-band radiometers. The response values in the red, green and blue bands, quantified by RGB values of digital images of the water surface, were comparable to measurements of irradiance levels at red, green and cyan/blue wavelengths of water leaving light. Different systems were deployed to capture upwelling light from below the surface, while eliminating direct surface reflection. Relationships between RGB ratios of water surface images, and water quality parameters were found to be consistent with previous measurements using more traditional narrow-band radiometers. This current paper focuses on the method that was used to acquire digital images, derive RGB values and relate measurements to water quality parameters. Field measurements were obtained in Galway Bay, Ireland, and in the Southern Rockall Trough in the North Atlantic, where both yellow substance and chlorophyll concentrations were successfully assessed using the digital camera method. Molecular Diversity Preservation International (MDPI) 2009-07-22 /pmc/articles/PMC3274132/ /pubmed/22346729 http://dx.doi.org/10.3390/s90705825 Text en © 2009 by the authors; licensee MDPI, Basel, Switzerland This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Goddijn-Murphy, Lonneke
Dailloux, Damien
White, Martin
Bowers, Dave
Fundamentals of in Situ Digital Camera Methodology for Water Quality Monitoring of Coast and Ocean
title Fundamentals of in Situ Digital Camera Methodology for Water Quality Monitoring of Coast and Ocean
title_full Fundamentals of in Situ Digital Camera Methodology for Water Quality Monitoring of Coast and Ocean
title_fullStr Fundamentals of in Situ Digital Camera Methodology for Water Quality Monitoring of Coast and Ocean
title_full_unstemmed Fundamentals of in Situ Digital Camera Methodology for Water Quality Monitoring of Coast and Ocean
title_short Fundamentals of in Situ Digital Camera Methodology for Water Quality Monitoring of Coast and Ocean
title_sort fundamentals of in situ digital camera methodology for water quality monitoring of coast and ocean
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3274132/
https://www.ncbi.nlm.nih.gov/pubmed/22346729
http://dx.doi.org/10.3390/s90705825
work_keys_str_mv AT goddijnmurphylonneke fundamentalsofinsitudigitalcameramethodologyforwaterqualitymonitoringofcoastandocean
AT daillouxdamien fundamentalsofinsitudigitalcameramethodologyforwaterqualitymonitoringofcoastandocean
AT whitemartin fundamentalsofinsitudigitalcameramethodologyforwaterqualitymonitoringofcoastandocean
AT bowersdave fundamentalsofinsitudigitalcameramethodologyforwaterqualitymonitoringofcoastandocean