Flexible Temperature Sensor Array Based on a Graphite-Polydimethylsiloxane Composite

This paper presents a novel method to fabricate temperature sensor arrays by dispensing a graphite-polydimethylsiloxane composite on flexible polyimide films. The fabricated temperature sensor array has 64 sensing cells in a 4 × 4 cm(2) area. The sensor array can be used as humanoid artificial skin...

Descripción completa

Detalles Bibliográficos
Autores principales: Shih, Wen-Pin, Tsao, Li-Chi, Lee, Chian-Wen, Cheng, Ming-Yuan, Chang, Chienliu, Yang, Yao-Joe, Fan, Kuang-Chao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3274235/
https://www.ncbi.nlm.nih.gov/pubmed/22319314
http://dx.doi.org/10.3390/s100403597
_version_ 1782223040444104704
author Shih, Wen-Pin
Tsao, Li-Chi
Lee, Chian-Wen
Cheng, Ming-Yuan
Chang, Chienliu
Yang, Yao-Joe
Fan, Kuang-Chao
author_facet Shih, Wen-Pin
Tsao, Li-Chi
Lee, Chian-Wen
Cheng, Ming-Yuan
Chang, Chienliu
Yang, Yao-Joe
Fan, Kuang-Chao
author_sort Shih, Wen-Pin
collection PubMed
description This paper presents a novel method to fabricate temperature sensor arrays by dispensing a graphite-polydimethylsiloxane composite on flexible polyimide films. The fabricated temperature sensor array has 64 sensing cells in a 4 × 4 cm(2) area. The sensor array can be used as humanoid artificial skin for sensation system of robots. Interdigitated copper electrodes were patterned on the flexible polyimide substrate for determining the resistivity change of the composites subjected to ambient temperature variations. Polydimethylsiloxane was used as the matrix. Composites of different graphite volume fractions for large dynamic range from 30 °C to 110 °C have been investigated. Our experiments showed that graphite powder provided the composite high temperature sensitivity. The fabricated temperature sensor array has been tested. The detected temperature contours are in good agreement with the shapes and magnitudes of different heat sources.
format Online
Article
Text
id pubmed-3274235
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-32742352012-02-08 Flexible Temperature Sensor Array Based on a Graphite-Polydimethylsiloxane Composite Shih, Wen-Pin Tsao, Li-Chi Lee, Chian-Wen Cheng, Ming-Yuan Chang, Chienliu Yang, Yao-Joe Fan, Kuang-Chao Sensors (Basel) Article This paper presents a novel method to fabricate temperature sensor arrays by dispensing a graphite-polydimethylsiloxane composite on flexible polyimide films. The fabricated temperature sensor array has 64 sensing cells in a 4 × 4 cm(2) area. The sensor array can be used as humanoid artificial skin for sensation system of robots. Interdigitated copper electrodes were patterned on the flexible polyimide substrate for determining the resistivity change of the composites subjected to ambient temperature variations. Polydimethylsiloxane was used as the matrix. Composites of different graphite volume fractions for large dynamic range from 30 °C to 110 °C have been investigated. Our experiments showed that graphite powder provided the composite high temperature sensitivity. The fabricated temperature sensor array has been tested. The detected temperature contours are in good agreement with the shapes and magnitudes of different heat sources. Molecular Diversity Preservation International (MDPI) 2010-04-09 /pmc/articles/PMC3274235/ /pubmed/22319314 http://dx.doi.org/10.3390/s100403597 Text en © 2010 by the authors; licensee Molecular Diversity Preservation International, Basel, Switzerland. This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Shih, Wen-Pin
Tsao, Li-Chi
Lee, Chian-Wen
Cheng, Ming-Yuan
Chang, Chienliu
Yang, Yao-Joe
Fan, Kuang-Chao
Flexible Temperature Sensor Array Based on a Graphite-Polydimethylsiloxane Composite
title Flexible Temperature Sensor Array Based on a Graphite-Polydimethylsiloxane Composite
title_full Flexible Temperature Sensor Array Based on a Graphite-Polydimethylsiloxane Composite
title_fullStr Flexible Temperature Sensor Array Based on a Graphite-Polydimethylsiloxane Composite
title_full_unstemmed Flexible Temperature Sensor Array Based on a Graphite-Polydimethylsiloxane Composite
title_short Flexible Temperature Sensor Array Based on a Graphite-Polydimethylsiloxane Composite
title_sort flexible temperature sensor array based on a graphite-polydimethylsiloxane composite
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3274235/
https://www.ncbi.nlm.nih.gov/pubmed/22319314
http://dx.doi.org/10.3390/s100403597
work_keys_str_mv AT shihwenpin flexibletemperaturesensorarraybasedonagraphitepolydimethylsiloxanecomposite
AT tsaolichi flexibletemperaturesensorarraybasedonagraphitepolydimethylsiloxanecomposite
AT leechianwen flexibletemperaturesensorarraybasedonagraphitepolydimethylsiloxanecomposite
AT chengmingyuan flexibletemperaturesensorarraybasedonagraphitepolydimethylsiloxanecomposite
AT changchienliu flexibletemperaturesensorarraybasedonagraphitepolydimethylsiloxanecomposite
AT yangyaojoe flexibletemperaturesensorarraybasedonagraphitepolydimethylsiloxanecomposite
AT fankuangchao flexibletemperaturesensorarraybasedonagraphitepolydimethylsiloxanecomposite