LPS Auto-Calibration Algorithm with Predetermination of Optimal Zones

Accurate coordinates for active beacons placed in the environment are required in Local Positioning Systems (LPS). These coordinates and the distances (or differences of distances) measured between the beacons and the mobile node to be localized are inputs to most trilateration algorithms. As a firs...

Descripción completa

Detalles Bibliográficos
Autores principales: Ruiz, Francisco Daniel, Ureña, Jesús, García, Juan C., Jiménez, Ana, Hernández, Álvaro, García, Juan J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3274291/
https://www.ncbi.nlm.nih.gov/pubmed/22346649
http://dx.doi.org/10.3390/s111110398
_version_ 1782223053448544256
author Ruiz, Francisco Daniel
Ureña, Jesús
García, Juan C.
Jiménez, Ana
Hernández, Álvaro
García, Juan J.
author_facet Ruiz, Francisco Daniel
Ureña, Jesús
García, Juan C.
Jiménez, Ana
Hernández, Álvaro
García, Juan J.
author_sort Ruiz, Francisco Daniel
collection PubMed
description Accurate coordinates for active beacons placed in the environment are required in Local Positioning Systems (LPS). These coordinates and the distances (or differences of distances) measured between the beacons and the mobile node to be localized are inputs to most trilateration algorithms. As a first approximation, such coordinates are obtained by means of manual measurements (a time-consuming and non-flexible method), or by using a calibration algorithm (i.e., automatic determination of beacon coordinates from ad hoc measurements). This paper presents a method to calibrate the beacons’ positions in a LPS using a mobile receiver. The method has been developed for both, spherical and hyperbolic trilateration. The location of only three test points must be known a priori, while the position of the other test points can be unknown. Furthermore, the paper describes a procedure to estimate the optimal positions, or approximate areas in the coverage zone, where the test-points necessary to calibrate the ultrasonic LPS should be placed. Simulation and experimental results show the improvement achieved when these optimal test-points are used instead of randomly selected ones.
format Online
Article
Text
id pubmed-3274291
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-32742912012-02-15 LPS Auto-Calibration Algorithm with Predetermination of Optimal Zones Ruiz, Francisco Daniel Ureña, Jesús García, Juan C. Jiménez, Ana Hernández, Álvaro García, Juan J. Sensors (Basel) Article Accurate coordinates for active beacons placed in the environment are required in Local Positioning Systems (LPS). These coordinates and the distances (or differences of distances) measured between the beacons and the mobile node to be localized are inputs to most trilateration algorithms. As a first approximation, such coordinates are obtained by means of manual measurements (a time-consuming and non-flexible method), or by using a calibration algorithm (i.e., automatic determination of beacon coordinates from ad hoc measurements). This paper presents a method to calibrate the beacons’ positions in a LPS using a mobile receiver. The method has been developed for both, spherical and hyperbolic trilateration. The location of only three test points must be known a priori, while the position of the other test points can be unknown. Furthermore, the paper describes a procedure to estimate the optimal positions, or approximate areas in the coverage zone, where the test-points necessary to calibrate the ultrasonic LPS should be placed. Simulation and experimental results show the improvement achieved when these optimal test-points are used instead of randomly selected ones. Molecular Diversity Preservation International (MDPI) 2011-10-31 /pmc/articles/PMC3274291/ /pubmed/22346649 http://dx.doi.org/10.3390/s111110398 Text en © 2011 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Ruiz, Francisco Daniel
Ureña, Jesús
García, Juan C.
Jiménez, Ana
Hernández, Álvaro
García, Juan J.
LPS Auto-Calibration Algorithm with Predetermination of Optimal Zones
title LPS Auto-Calibration Algorithm with Predetermination of Optimal Zones
title_full LPS Auto-Calibration Algorithm with Predetermination of Optimal Zones
title_fullStr LPS Auto-Calibration Algorithm with Predetermination of Optimal Zones
title_full_unstemmed LPS Auto-Calibration Algorithm with Predetermination of Optimal Zones
title_short LPS Auto-Calibration Algorithm with Predetermination of Optimal Zones
title_sort lps auto-calibration algorithm with predetermination of optimal zones
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3274291/
https://www.ncbi.nlm.nih.gov/pubmed/22346649
http://dx.doi.org/10.3390/s111110398
work_keys_str_mv AT ruizfranciscodaniel lpsautocalibrationalgorithmwithpredeterminationofoptimalzones
AT urenajesus lpsautocalibrationalgorithmwithpredeterminationofoptimalzones
AT garciajuanc lpsautocalibrationalgorithmwithpredeterminationofoptimalzones
AT jimenezana lpsautocalibrationalgorithmwithpredeterminationofoptimalzones
AT hernandezalvaro lpsautocalibrationalgorithmwithpredeterminationofoptimalzones
AT garciajuanj lpsautocalibrationalgorithmwithpredeterminationofoptimalzones