Critical Appraisal of Four IL-6 Immunoassays

BACKGROUND: Interleukin-6 (IL-6) contributes to numerous inflammatory, metabolic, and physiologic pathways of disease. We evaluated four IL-6 immunoassays in order to identify a reliable assay for studies of metabolic and physical function. Serial plasma samples from intravenous glucose tolerance te...

Descripción completa

Detalles Bibliográficos
Autores principales: Thompson, Dana K., Huffman, Kim M., Kraus, William E., Kraus, Virginia Byers
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3276568/
https://www.ncbi.nlm.nih.gov/pubmed/22347395
http://dx.doi.org/10.1371/journal.pone.0030659
_version_ 1782223387303608320
author Thompson, Dana K.
Huffman, Kim M.
Kraus, William E.
Kraus, Virginia Byers
author_facet Thompson, Dana K.
Huffman, Kim M.
Kraus, William E.
Kraus, Virginia Byers
author_sort Thompson, Dana K.
collection PubMed
description BACKGROUND: Interleukin-6 (IL-6) contributes to numerous inflammatory, metabolic, and physiologic pathways of disease. We evaluated four IL-6 immunoassays in order to identify a reliable assay for studies of metabolic and physical function. Serial plasma samples from intravenous glucose tolerance tests (IVGTTs), with expected rises in IL-6 concentrations, were used to test the face validity of the various assays. METHODS AND FINDINGS: IVGTTs, administered to 14 subjects, were performed with a single infusion of glucose (0.3 g/kg body mass) at time zero, a single infusion of insulin (0.025 U/kg body mass) at 20 minutes, and frequent blood collection from time zero to 180 minutes for subsequent Il-6 measurement. The performance metrics of four IL-6 detection methods were compared: Meso Scale Discovery immunoassay (MSD), an Invitrogen Luminex bead-based multiplex panel (LX), an Invitrogen Ultrasensitive Luminex bead-based singleplex assay (ULX), and R&D High Sensitivity ELISA (R&D). IL-6 concentrations measured with MSD, R&D and ULX correlated with each other (Pearson Correlation Coefficients r = 0.47–0.94, p<0.0001) but only ULX correlated (r = 0.31, p = 0.0027) with Invitrogen Luminex. MSD, R&D, and ULX, but not LX, detected increases in IL-6 in response to glucose. All plasma samples were measurable by MSD, while 35%, 1%, and 4.3% of samples were out of range when measured by LX, ULX, and R&D, respectively. Based on representative data from the MSD assay, baseline plasma IL-6 (0.90±0.48 pg/mL) increased significantly as expected by 90 minutes (1.29±0.59 pg/mL, p = 0.049), and continued rising through 3 hours (4.25±3.67 pg/mL, p = 0.0048). CONCLUSION: This study established the face validity of IL-6 measurement by MSD, R&D, and ULX but not LX, and the superiority of MSD with respect to dynamic range. Plasma IL-6 concentrations increase in response to glucose and insulin, consistent with both an early glucose-dependent response (detectable at 1–2 hours) and a late insulin-dependent response (detectable after 2 hours).
format Online
Article
Text
id pubmed-3276568
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-32765682012-02-15 Critical Appraisal of Four IL-6 Immunoassays Thompson, Dana K. Huffman, Kim M. Kraus, William E. Kraus, Virginia Byers PLoS One Research Article BACKGROUND: Interleukin-6 (IL-6) contributes to numerous inflammatory, metabolic, and physiologic pathways of disease. We evaluated four IL-6 immunoassays in order to identify a reliable assay for studies of metabolic and physical function. Serial plasma samples from intravenous glucose tolerance tests (IVGTTs), with expected rises in IL-6 concentrations, were used to test the face validity of the various assays. METHODS AND FINDINGS: IVGTTs, administered to 14 subjects, were performed with a single infusion of glucose (0.3 g/kg body mass) at time zero, a single infusion of insulin (0.025 U/kg body mass) at 20 minutes, and frequent blood collection from time zero to 180 minutes for subsequent Il-6 measurement. The performance metrics of four IL-6 detection methods were compared: Meso Scale Discovery immunoassay (MSD), an Invitrogen Luminex bead-based multiplex panel (LX), an Invitrogen Ultrasensitive Luminex bead-based singleplex assay (ULX), and R&D High Sensitivity ELISA (R&D). IL-6 concentrations measured with MSD, R&D and ULX correlated with each other (Pearson Correlation Coefficients r = 0.47–0.94, p<0.0001) but only ULX correlated (r = 0.31, p = 0.0027) with Invitrogen Luminex. MSD, R&D, and ULX, but not LX, detected increases in IL-6 in response to glucose. All plasma samples were measurable by MSD, while 35%, 1%, and 4.3% of samples were out of range when measured by LX, ULX, and R&D, respectively. Based on representative data from the MSD assay, baseline plasma IL-6 (0.90±0.48 pg/mL) increased significantly as expected by 90 minutes (1.29±0.59 pg/mL, p = 0.049), and continued rising through 3 hours (4.25±3.67 pg/mL, p = 0.0048). CONCLUSION: This study established the face validity of IL-6 measurement by MSD, R&D, and ULX but not LX, and the superiority of MSD with respect to dynamic range. Plasma IL-6 concentrations increase in response to glucose and insulin, consistent with both an early glucose-dependent response (detectable at 1–2 hours) and a late insulin-dependent response (detectable after 2 hours). Public Library of Science 2012-02-09 /pmc/articles/PMC3276568/ /pubmed/22347395 http://dx.doi.org/10.1371/journal.pone.0030659 Text en This is an open-access article, free of all copyright, and may be freely reproduced, distributed, transmitted, modified, built upon, or otherwise used by anyone for any lawful purpose. The work is made available under the Creative Commons CC0 public domain dedication. https://creativecommons.org/publicdomain/zero/1.0/ This is an open-access article distributed under the terms of the Creative Commons Public Domain declaration, which stipulates that, once placed in the public domain, this work may be freely reproduced, distributed, transmitted, modified, built upon, or otherwise used by anyone for any lawful purpose.
spellingShingle Research Article
Thompson, Dana K.
Huffman, Kim M.
Kraus, William E.
Kraus, Virginia Byers
Critical Appraisal of Four IL-6 Immunoassays
title Critical Appraisal of Four IL-6 Immunoassays
title_full Critical Appraisal of Four IL-6 Immunoassays
title_fullStr Critical Appraisal of Four IL-6 Immunoassays
title_full_unstemmed Critical Appraisal of Four IL-6 Immunoassays
title_short Critical Appraisal of Four IL-6 Immunoassays
title_sort critical appraisal of four il-6 immunoassays
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3276568/
https://www.ncbi.nlm.nih.gov/pubmed/22347395
http://dx.doi.org/10.1371/journal.pone.0030659
work_keys_str_mv AT thompsondanak criticalappraisaloffouril6immunoassays
AT huffmankimm criticalappraisaloffouril6immunoassays
AT krauswilliame criticalappraisaloffouril6immunoassays
AT krausvirginiabyers criticalappraisaloffouril6immunoassays