Accuracy of LightCycler® SeptiFast for the detection and identification of pathogens in the blood of patients with suspected sepsis: a systematic review protocol

BACKGROUND: There is growing interest in the potential utility of molecular diagnostics in improving the detection of life-threatening infection (sepsis). LightCycler® SeptiFast is a multipathogen probe-based real-time PCR system targeting DNA sequences of bacteria and fungi present in blood samples...

Descripción completa

Detalles Bibliográficos
Autores principales: Dark, Paul, Wilson, Claire, Blackwood, Bronagh, McAuley, Danny F, Perkins, Gavin D, McMullan, Ronan, Gates, Simon, Warhurst, Geoffrey
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Group 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3278490/
https://www.ncbi.nlm.nih.gov/pubmed/22240646
http://dx.doi.org/10.1136/bmjopen-2011-000392
_version_ 1782223584059457536
author Dark, Paul
Wilson, Claire
Blackwood, Bronagh
McAuley, Danny F
Perkins, Gavin D
McMullan, Ronan
Gates, Simon
Warhurst, Geoffrey
author_facet Dark, Paul
Wilson, Claire
Blackwood, Bronagh
McAuley, Danny F
Perkins, Gavin D
McMullan, Ronan
Gates, Simon
Warhurst, Geoffrey
author_sort Dark, Paul
collection PubMed
description BACKGROUND: There is growing interest in the potential utility of molecular diagnostics in improving the detection of life-threatening infection (sepsis). LightCycler® SeptiFast is a multipathogen probe-based real-time PCR system targeting DNA sequences of bacteria and fungi present in blood samples within a few hours. We report here the protocol of the first systematic review of published clinical diagnostic accuracy studies of this technology when compared with blood culture in the setting of suspected sepsis. METHODS/DESIGN: Data sources: the Cochrane Database of Systematic Reviews, the Database of Abstracts of Reviews of Effects (DARE), the Health Technology Assessment Database (HTA), the NHS Economic Evaluation Database (NHSEED), The Cochrane Library, MEDLINE, EMBASE, ISI Web of Science, BIOSIS Previews, MEDION and the Aggressive Research Intelligence Facility Database (ARIF). Study selection: diagnostic accuracy studies that compare the real-time PCR technology with standard culture results performed on a patient's blood sample during the management of sepsis. Data extraction: three reviewers, working independently, will determine the level of evidence, methodological quality and a standard data set relating to demographics and diagnostic accuracy metrics for each study. Statistical analysis/data synthesis: heterogeneity of studies will be investigated using a coupled forest plot of sensitivity and specificity and a scatter plot in Receiver Operator Characteristic (ROC) space. Bivariate model method will be used to estimate summary sensitivity and specificity. The authors will investigate reporting biases using funnel plots based on effective sample size and regression tests of asymmetry. Subgroup analyses are planned for adults, children and infection setting (hospital vs community) if sufficient data are uncovered. DISSEMINATION: Recommendations will be made to the Department of Health (as part of an open-access HTA report) as to whether the real-time PCR technology has sufficient clinical diagnostic accuracy potential to move forward to efficacy testing during the provision of routine clinical care. REGISTRATION: PROSPERO—NIHR Prospective Register of Systematic Reviews (CRD42011001289).
format Online
Article
Text
id pubmed-3278490
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BMJ Group
record_format MEDLINE/PubMed
spelling pubmed-32784902012-02-17 Accuracy of LightCycler® SeptiFast for the detection and identification of pathogens in the blood of patients with suspected sepsis: a systematic review protocol Dark, Paul Wilson, Claire Blackwood, Bronagh McAuley, Danny F Perkins, Gavin D McMullan, Ronan Gates, Simon Warhurst, Geoffrey BMJ Open Intensive Care BACKGROUND: There is growing interest in the potential utility of molecular diagnostics in improving the detection of life-threatening infection (sepsis). LightCycler® SeptiFast is a multipathogen probe-based real-time PCR system targeting DNA sequences of bacteria and fungi present in blood samples within a few hours. We report here the protocol of the first systematic review of published clinical diagnostic accuracy studies of this technology when compared with blood culture in the setting of suspected sepsis. METHODS/DESIGN: Data sources: the Cochrane Database of Systematic Reviews, the Database of Abstracts of Reviews of Effects (DARE), the Health Technology Assessment Database (HTA), the NHS Economic Evaluation Database (NHSEED), The Cochrane Library, MEDLINE, EMBASE, ISI Web of Science, BIOSIS Previews, MEDION and the Aggressive Research Intelligence Facility Database (ARIF). Study selection: diagnostic accuracy studies that compare the real-time PCR technology with standard culture results performed on a patient's blood sample during the management of sepsis. Data extraction: three reviewers, working independently, will determine the level of evidence, methodological quality and a standard data set relating to demographics and diagnostic accuracy metrics for each study. Statistical analysis/data synthesis: heterogeneity of studies will be investigated using a coupled forest plot of sensitivity and specificity and a scatter plot in Receiver Operator Characteristic (ROC) space. Bivariate model method will be used to estimate summary sensitivity and specificity. The authors will investigate reporting biases using funnel plots based on effective sample size and regression tests of asymmetry. Subgroup analyses are planned for adults, children and infection setting (hospital vs community) if sufficient data are uncovered. DISSEMINATION: Recommendations will be made to the Department of Health (as part of an open-access HTA report) as to whether the real-time PCR technology has sufficient clinical diagnostic accuracy potential to move forward to efficacy testing during the provision of routine clinical care. REGISTRATION: PROSPERO—NIHR Prospective Register of Systematic Reviews (CRD42011001289). BMJ Group 2012-01-12 /pmc/articles/PMC3278490/ /pubmed/22240646 http://dx.doi.org/10.1136/bmjopen-2011-000392 Text en © 2012, Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions. This is an open-access article distributed under the terms of the Creative Commons Attribution Non-commercial License, which permits use, distribution, and reproduction in any medium, provided the original work is properly cited, the use is non commercial and is otherwise in compliance with the license. See: http://creativecommons.org/licenses/by-nc/2.0/ and http://creativecommons.org/licenses/by-nc/2.0/legalcode.
spellingShingle Intensive Care
Dark, Paul
Wilson, Claire
Blackwood, Bronagh
McAuley, Danny F
Perkins, Gavin D
McMullan, Ronan
Gates, Simon
Warhurst, Geoffrey
Accuracy of LightCycler® SeptiFast for the detection and identification of pathogens in the blood of patients with suspected sepsis: a systematic review protocol
title Accuracy of LightCycler® SeptiFast for the detection and identification of pathogens in the blood of patients with suspected sepsis: a systematic review protocol
title_full Accuracy of LightCycler® SeptiFast for the detection and identification of pathogens in the blood of patients with suspected sepsis: a systematic review protocol
title_fullStr Accuracy of LightCycler® SeptiFast for the detection and identification of pathogens in the blood of patients with suspected sepsis: a systematic review protocol
title_full_unstemmed Accuracy of LightCycler® SeptiFast for the detection and identification of pathogens in the blood of patients with suspected sepsis: a systematic review protocol
title_short Accuracy of LightCycler® SeptiFast for the detection and identification of pathogens in the blood of patients with suspected sepsis: a systematic review protocol
title_sort accuracy of lightcycler® septifast for the detection and identification of pathogens in the blood of patients with suspected sepsis: a systematic review protocol
topic Intensive Care
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3278490/
https://www.ncbi.nlm.nih.gov/pubmed/22240646
http://dx.doi.org/10.1136/bmjopen-2011-000392
work_keys_str_mv AT darkpaul accuracyoflightcyclerseptifastforthedetectionandidentificationofpathogensinthebloodofpatientswithsuspectedsepsisasystematicreviewprotocol
AT wilsonclaire accuracyoflightcyclerseptifastforthedetectionandidentificationofpathogensinthebloodofpatientswithsuspectedsepsisasystematicreviewprotocol
AT blackwoodbronagh accuracyoflightcyclerseptifastforthedetectionandidentificationofpathogensinthebloodofpatientswithsuspectedsepsisasystematicreviewprotocol
AT mcauleydannyf accuracyoflightcyclerseptifastforthedetectionandidentificationofpathogensinthebloodofpatientswithsuspectedsepsisasystematicreviewprotocol
AT perkinsgavind accuracyoflightcyclerseptifastforthedetectionandidentificationofpathogensinthebloodofpatientswithsuspectedsepsisasystematicreviewprotocol
AT mcmullanronan accuracyoflightcyclerseptifastforthedetectionandidentificationofpathogensinthebloodofpatientswithsuspectedsepsisasystematicreviewprotocol
AT gatessimon accuracyoflightcyclerseptifastforthedetectionandidentificationofpathogensinthebloodofpatientswithsuspectedsepsisasystematicreviewprotocol
AT warhurstgeoffrey accuracyoflightcyclerseptifastforthedetectionandidentificationofpathogensinthebloodofpatientswithsuspectedsepsisasystematicreviewprotocol