Cargando…
Accuracy of LightCycler® SeptiFast for the detection and identification of pathogens in the blood of patients with suspected sepsis: a systematic review protocol
BACKGROUND: There is growing interest in the potential utility of molecular diagnostics in improving the detection of life-threatening infection (sepsis). LightCycler® SeptiFast is a multipathogen probe-based real-time PCR system targeting DNA sequences of bacteria and fungi present in blood samples...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Group
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3278490/ https://www.ncbi.nlm.nih.gov/pubmed/22240646 http://dx.doi.org/10.1136/bmjopen-2011-000392 |
_version_ | 1782223584059457536 |
---|---|
author | Dark, Paul Wilson, Claire Blackwood, Bronagh McAuley, Danny F Perkins, Gavin D McMullan, Ronan Gates, Simon Warhurst, Geoffrey |
author_facet | Dark, Paul Wilson, Claire Blackwood, Bronagh McAuley, Danny F Perkins, Gavin D McMullan, Ronan Gates, Simon Warhurst, Geoffrey |
author_sort | Dark, Paul |
collection | PubMed |
description | BACKGROUND: There is growing interest in the potential utility of molecular diagnostics in improving the detection of life-threatening infection (sepsis). LightCycler® SeptiFast is a multipathogen probe-based real-time PCR system targeting DNA sequences of bacteria and fungi present in blood samples within a few hours. We report here the protocol of the first systematic review of published clinical diagnostic accuracy studies of this technology when compared with blood culture in the setting of suspected sepsis. METHODS/DESIGN: Data sources: the Cochrane Database of Systematic Reviews, the Database of Abstracts of Reviews of Effects (DARE), the Health Technology Assessment Database (HTA), the NHS Economic Evaluation Database (NHSEED), The Cochrane Library, MEDLINE, EMBASE, ISI Web of Science, BIOSIS Previews, MEDION and the Aggressive Research Intelligence Facility Database (ARIF). Study selection: diagnostic accuracy studies that compare the real-time PCR technology with standard culture results performed on a patient's blood sample during the management of sepsis. Data extraction: three reviewers, working independently, will determine the level of evidence, methodological quality and a standard data set relating to demographics and diagnostic accuracy metrics for each study. Statistical analysis/data synthesis: heterogeneity of studies will be investigated using a coupled forest plot of sensitivity and specificity and a scatter plot in Receiver Operator Characteristic (ROC) space. Bivariate model method will be used to estimate summary sensitivity and specificity. The authors will investigate reporting biases using funnel plots based on effective sample size and regression tests of asymmetry. Subgroup analyses are planned for adults, children and infection setting (hospital vs community) if sufficient data are uncovered. DISSEMINATION: Recommendations will be made to the Department of Health (as part of an open-access HTA report) as to whether the real-time PCR technology has sufficient clinical diagnostic accuracy potential to move forward to efficacy testing during the provision of routine clinical care. REGISTRATION: PROSPERO—NIHR Prospective Register of Systematic Reviews (CRD42011001289). |
format | Online Article Text |
id | pubmed-3278490 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | BMJ Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-32784902012-02-17 Accuracy of LightCycler® SeptiFast for the detection and identification of pathogens in the blood of patients with suspected sepsis: a systematic review protocol Dark, Paul Wilson, Claire Blackwood, Bronagh McAuley, Danny F Perkins, Gavin D McMullan, Ronan Gates, Simon Warhurst, Geoffrey BMJ Open Intensive Care BACKGROUND: There is growing interest in the potential utility of molecular diagnostics in improving the detection of life-threatening infection (sepsis). LightCycler® SeptiFast is a multipathogen probe-based real-time PCR system targeting DNA sequences of bacteria and fungi present in blood samples within a few hours. We report here the protocol of the first systematic review of published clinical diagnostic accuracy studies of this technology when compared with blood culture in the setting of suspected sepsis. METHODS/DESIGN: Data sources: the Cochrane Database of Systematic Reviews, the Database of Abstracts of Reviews of Effects (DARE), the Health Technology Assessment Database (HTA), the NHS Economic Evaluation Database (NHSEED), The Cochrane Library, MEDLINE, EMBASE, ISI Web of Science, BIOSIS Previews, MEDION and the Aggressive Research Intelligence Facility Database (ARIF). Study selection: diagnostic accuracy studies that compare the real-time PCR technology with standard culture results performed on a patient's blood sample during the management of sepsis. Data extraction: three reviewers, working independently, will determine the level of evidence, methodological quality and a standard data set relating to demographics and diagnostic accuracy metrics for each study. Statistical analysis/data synthesis: heterogeneity of studies will be investigated using a coupled forest plot of sensitivity and specificity and a scatter plot in Receiver Operator Characteristic (ROC) space. Bivariate model method will be used to estimate summary sensitivity and specificity. The authors will investigate reporting biases using funnel plots based on effective sample size and regression tests of asymmetry. Subgroup analyses are planned for adults, children and infection setting (hospital vs community) if sufficient data are uncovered. DISSEMINATION: Recommendations will be made to the Department of Health (as part of an open-access HTA report) as to whether the real-time PCR technology has sufficient clinical diagnostic accuracy potential to move forward to efficacy testing during the provision of routine clinical care. REGISTRATION: PROSPERO—NIHR Prospective Register of Systematic Reviews (CRD42011001289). BMJ Group 2012-01-12 /pmc/articles/PMC3278490/ /pubmed/22240646 http://dx.doi.org/10.1136/bmjopen-2011-000392 Text en © 2012, Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions. This is an open-access article distributed under the terms of the Creative Commons Attribution Non-commercial License, which permits use, distribution, and reproduction in any medium, provided the original work is properly cited, the use is non commercial and is otherwise in compliance with the license. See: http://creativecommons.org/licenses/by-nc/2.0/ and http://creativecommons.org/licenses/by-nc/2.0/legalcode. |
spellingShingle | Intensive Care Dark, Paul Wilson, Claire Blackwood, Bronagh McAuley, Danny F Perkins, Gavin D McMullan, Ronan Gates, Simon Warhurst, Geoffrey Accuracy of LightCycler® SeptiFast for the detection and identification of pathogens in the blood of patients with suspected sepsis: a systematic review protocol |
title | Accuracy of LightCycler® SeptiFast for the detection and identification of pathogens in the blood of patients with suspected sepsis: a systematic review protocol |
title_full | Accuracy of LightCycler® SeptiFast for the detection and identification of pathogens in the blood of patients with suspected sepsis: a systematic review protocol |
title_fullStr | Accuracy of LightCycler® SeptiFast for the detection and identification of pathogens in the blood of patients with suspected sepsis: a systematic review protocol |
title_full_unstemmed | Accuracy of LightCycler® SeptiFast for the detection and identification of pathogens in the blood of patients with suspected sepsis: a systematic review protocol |
title_short | Accuracy of LightCycler® SeptiFast for the detection and identification of pathogens in the blood of patients with suspected sepsis: a systematic review protocol |
title_sort | accuracy of lightcycler® septifast for the detection and identification of pathogens in the blood of patients with suspected sepsis: a systematic review protocol |
topic | Intensive Care |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3278490/ https://www.ncbi.nlm.nih.gov/pubmed/22240646 http://dx.doi.org/10.1136/bmjopen-2011-000392 |
work_keys_str_mv | AT darkpaul accuracyoflightcyclerseptifastforthedetectionandidentificationofpathogensinthebloodofpatientswithsuspectedsepsisasystematicreviewprotocol AT wilsonclaire accuracyoflightcyclerseptifastforthedetectionandidentificationofpathogensinthebloodofpatientswithsuspectedsepsisasystematicreviewprotocol AT blackwoodbronagh accuracyoflightcyclerseptifastforthedetectionandidentificationofpathogensinthebloodofpatientswithsuspectedsepsisasystematicreviewprotocol AT mcauleydannyf accuracyoflightcyclerseptifastforthedetectionandidentificationofpathogensinthebloodofpatientswithsuspectedsepsisasystematicreviewprotocol AT perkinsgavind accuracyoflightcyclerseptifastforthedetectionandidentificationofpathogensinthebloodofpatientswithsuspectedsepsisasystematicreviewprotocol AT mcmullanronan accuracyoflightcyclerseptifastforthedetectionandidentificationofpathogensinthebloodofpatientswithsuspectedsepsisasystematicreviewprotocol AT gatessimon accuracyoflightcyclerseptifastforthedetectionandidentificationofpathogensinthebloodofpatientswithsuspectedsepsisasystematicreviewprotocol AT warhurstgeoffrey accuracyoflightcyclerseptifastforthedetectionandidentificationofpathogensinthebloodofpatientswithsuspectedsepsisasystematicreviewprotocol |