Cargando…
A Magnetic Flux Leakage and Magnetostrictive Guided Wave Hybrid Transducer for Detecting Bridge Cables
Condition assessment of cables has gained considerable attention for the bridge safety. A magnetic flux leakage and magnetostrictive guided wave hybrid transducer is provided to inspect bridge cables. The similarities and differences between the two methods are investigated. The hybrid transducer fo...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3279227/ https://www.ncbi.nlm.nih.gov/pubmed/22368483 http://dx.doi.org/10.3390/s120100518 |
_version_ | 1782223647760449536 |
---|---|
author | Xu, Jiang Wu, Xinjun Cheng, Cheng Ben, Anran |
author_facet | Xu, Jiang Wu, Xinjun Cheng, Cheng Ben, Anran |
author_sort | Xu, Jiang |
collection | PubMed |
description | Condition assessment of cables has gained considerable attention for the bridge safety. A magnetic flux leakage and magnetostrictive guided wave hybrid transducer is provided to inspect bridge cables. The similarities and differences between the two methods are investigated. The hybrid transducer for bridge cables consists of an aluminum framework, climbing modules, embedded magnetizers and a ribbon coil. The static axial magnetic field provided by the magnetizers meets the needs of the magnetic flux leakage testing and the magnetostrictive guided wave testing. The magnetizers also provide the attraction for the climbing modules. In the magnetic flux leakage testing for the free length of cable, the coil induces the axial leakage magnetic field. In the magnetostrictive guided wave testing for the anchorage zone, the coil provides a pulse high power variational magnetic field for generating guided waves; the coil induces the magnetic field variation for receiving guided waves. The experimental results show that the transducer with the corresponding inspection system could be applied to detect the broken wires in the free length and in the anchorage zone of bridge cables. |
format | Online Article Text |
id | pubmed-3279227 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-32792272012-02-24 A Magnetic Flux Leakage and Magnetostrictive Guided Wave Hybrid Transducer for Detecting Bridge Cables Xu, Jiang Wu, Xinjun Cheng, Cheng Ben, Anran Sensors (Basel) Article Condition assessment of cables has gained considerable attention for the bridge safety. A magnetic flux leakage and magnetostrictive guided wave hybrid transducer is provided to inspect bridge cables. The similarities and differences between the two methods are investigated. The hybrid transducer for bridge cables consists of an aluminum framework, climbing modules, embedded magnetizers and a ribbon coil. The static axial magnetic field provided by the magnetizers meets the needs of the magnetic flux leakage testing and the magnetostrictive guided wave testing. The magnetizers also provide the attraction for the climbing modules. In the magnetic flux leakage testing for the free length of cable, the coil induces the axial leakage magnetic field. In the magnetostrictive guided wave testing for the anchorage zone, the coil provides a pulse high power variational magnetic field for generating guided waves; the coil induces the magnetic field variation for receiving guided waves. The experimental results show that the transducer with the corresponding inspection system could be applied to detect the broken wires in the free length and in the anchorage zone of bridge cables. Molecular Diversity Preservation International (MDPI) 2012-01-05 /pmc/articles/PMC3279227/ /pubmed/22368483 http://dx.doi.org/10.3390/s120100518 Text en © 2012 by the authors; licensee MDPI, Basel, Switzerland This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Xu, Jiang Wu, Xinjun Cheng, Cheng Ben, Anran A Magnetic Flux Leakage and Magnetostrictive Guided Wave Hybrid Transducer for Detecting Bridge Cables |
title | A Magnetic Flux Leakage and Magnetostrictive Guided Wave Hybrid Transducer for Detecting Bridge Cables |
title_full | A Magnetic Flux Leakage and Magnetostrictive Guided Wave Hybrid Transducer for Detecting Bridge Cables |
title_fullStr | A Magnetic Flux Leakage and Magnetostrictive Guided Wave Hybrid Transducer for Detecting Bridge Cables |
title_full_unstemmed | A Magnetic Flux Leakage and Magnetostrictive Guided Wave Hybrid Transducer for Detecting Bridge Cables |
title_short | A Magnetic Flux Leakage and Magnetostrictive Guided Wave Hybrid Transducer for Detecting Bridge Cables |
title_sort | magnetic flux leakage and magnetostrictive guided wave hybrid transducer for detecting bridge cables |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3279227/ https://www.ncbi.nlm.nih.gov/pubmed/22368483 http://dx.doi.org/10.3390/s120100518 |
work_keys_str_mv | AT xujiang amagneticfluxleakageandmagnetostrictiveguidedwavehybridtransducerfordetectingbridgecables AT wuxinjun amagneticfluxleakageandmagnetostrictiveguidedwavehybridtransducerfordetectingbridgecables AT chengcheng amagneticfluxleakageandmagnetostrictiveguidedwavehybridtransducerfordetectingbridgecables AT benanran amagneticfluxleakageandmagnetostrictiveguidedwavehybridtransducerfordetectingbridgecables AT xujiang magneticfluxleakageandmagnetostrictiveguidedwavehybridtransducerfordetectingbridgecables AT wuxinjun magneticfluxleakageandmagnetostrictiveguidedwavehybridtransducerfordetectingbridgecables AT chengcheng magneticfluxleakageandmagnetostrictiveguidedwavehybridtransducerfordetectingbridgecables AT benanran magneticfluxleakageandmagnetostrictiveguidedwavehybridtransducerfordetectingbridgecables |