Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode
This paper describes a procedure for the determination of antimony (III) by differential pulse anodic stripping voltammetry using a mercury film screen-printed electrode as the working electrode. The procedure has been optimized using experimental design methodology. Under these conditions, in terms...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3280742/ https://www.ncbi.nlm.nih.gov/pubmed/22389596 http://dx.doi.org/10.3390/s90100219 |
_version_ | 1782223859172245504 |
---|---|
author | Domínguez-Renedo, Olga Gómez González, M. Jesús Arcos-Martínez, M. Julia |
author_facet | Domínguez-Renedo, Olga Gómez González, M. Jesús Arcos-Martínez, M. Julia |
author_sort | Domínguez-Renedo, Olga |
collection | PubMed |
description | This paper describes a procedure for the determination of antimony (III) by differential pulse anodic stripping voltammetry using a mercury film screen-printed electrode as the working electrode. The procedure has been optimized using experimental design methodology. Under these conditions, in terms of Residual Standard Deviation (RSD), the repeatability (3.81 %) and the reproducibility (5.07 %) of the constructed electrodes were both analyzed. The detection limit for Sb (III) was calculated at a value of 1.27×10(−8) M. The linear range obtained was between 0.99 × 10(−8) − 8.26 × 10(−8) M. An analysis of possible effects due to the presence of foreign ions in the solution was performed and the procedure was successfully applied to the determination of antimony levels in pharmaceutical preparations and sea water samples. |
format | Online Article Text |
id | pubmed-3280742 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-32807422012-03-02 Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode Domínguez-Renedo, Olga Gómez González, M. Jesús Arcos-Martínez, M. Julia Sensors (Basel) Article This paper describes a procedure for the determination of antimony (III) by differential pulse anodic stripping voltammetry using a mercury film screen-printed electrode as the working electrode. The procedure has been optimized using experimental design methodology. Under these conditions, in terms of Residual Standard Deviation (RSD), the repeatability (3.81 %) and the reproducibility (5.07 %) of the constructed electrodes were both analyzed. The detection limit for Sb (III) was calculated at a value of 1.27×10(−8) M. The linear range obtained was between 0.99 × 10(−8) − 8.26 × 10(−8) M. An analysis of possible effects due to the presence of foreign ions in the solution was performed and the procedure was successfully applied to the determination of antimony levels in pharmaceutical preparations and sea water samples. Molecular Diversity Preservation International (MDPI) 2009-01-08 /pmc/articles/PMC3280742/ /pubmed/22389596 http://dx.doi.org/10.3390/s90100219 Text en © 2009 by the authors; licensee Molecular Diversity Preservation International, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Domínguez-Renedo, Olga Gómez González, M. Jesús Arcos-Martínez, M. Julia Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode |
title | Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode |
title_full | Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode |
title_fullStr | Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode |
title_full_unstemmed | Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode |
title_short | Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode |
title_sort | determination of antimony (iii) in real samples by anodic stripping voltammetry using a mercury film screen-printed electrode |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3280742/ https://www.ncbi.nlm.nih.gov/pubmed/22389596 http://dx.doi.org/10.3390/s90100219 |
work_keys_str_mv | AT dominguezrenedoolga determinationofantimonyiiiinrealsamplesbyanodicstrippingvoltammetryusingamercuryfilmscreenprintedelectrode AT gomezgonzalezmjesus determinationofantimonyiiiinrealsamplesbyanodicstrippingvoltammetryusingamercuryfilmscreenprintedelectrode AT arcosmartinezmjulia determinationofantimonyiiiinrealsamplesbyanodicstrippingvoltammetryusingamercuryfilmscreenprintedelectrode |