Performance of Three Reflectance Calibration Methods for Airborne Hyperspectral Spectrometer Data

In this study, the performances and accuracies of three methods for converting airborne hyperspectral spectrometer data to reflectance factors were characterized and compared. The “reflectance mode (RM)” method, which calibrates a spectrometer against a white reference panel prior to mounting on an...

Descripción completa

Detalles Bibliográficos
Autores principales: Miura, Tomoaki, Huete, Alfredo R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3280831/
https://www.ncbi.nlm.nih.gov/pubmed/22399939
http://dx.doi.org/10.3390/s90200794
_version_ 1782223867557707776
author Miura, Tomoaki
Huete, Alfredo R.
author_facet Miura, Tomoaki
Huete, Alfredo R.
author_sort Miura, Tomoaki
collection PubMed
description In this study, the performances and accuracies of three methods for converting airborne hyperspectral spectrometer data to reflectance factors were characterized and compared. The “reflectance mode (RM)” method, which calibrates a spectrometer against a white reference panel prior to mounting on an aircraft, resulted in spectral reflectance retrievals that were biased and distorted. The magnitudes of these bias errors and distortions varied significantly, depending on time of day and length of the flight campaign. The “linear-interpolation (LI)” method, which converts airborne spectrometer data by taking a ratio of linearly-interpolated reference values from the preflight and post-flight reference panel readings, resulted in precise, but inaccurate reflectance retrievals. These reflectance spectra were not distorted, but were subject to bias errors of varying magnitudes dependent on the flight duration length. The “continuous panel (CP)” method uses a multi-band radiometer to obtain continuous measurements over a reference panel throughout the flight campaign, in order to adjust the magnitudes of the linear-interpolated reference values from the preflight and post-flight reference panel readings. Airborne hyperspectral reflectance retrievals obtained using this method were found to be the most accurate and reliable reflectance calibration method. The performances of the CP method in retrieving accurate reflectance factors were consistent throughout time of day and for various flight durations. Based on the dataset analyzed in this study, the uncertainty of the CP method has been estimated to be 0.0025 ± 0.0005 reflectance units for the wavelength regions not affected by atmospheric absorptions. The RM method can produce reasonable results only for a very short-term flight (e.g., < 15 minutes) conducted around a local solar noon. The flight duration should be kept shorter than 30 minutes for the LI method to produce results with reasonable accuracies. An important advantage of the CP method is that the method can be used for long-duration flight campaigns (e.g., 1-2 hours). Although this study focused on reflectance calibration of airborne spectrometer data, the methods evaluated in this study and the results obtained are directly applicable to ground spectrometer measurements.
format Online
Article
Text
id pubmed-3280831
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-32808312012-03-07 Performance of Three Reflectance Calibration Methods for Airborne Hyperspectral Spectrometer Data Miura, Tomoaki Huete, Alfredo R. Sensors (Basel) Article In this study, the performances and accuracies of three methods for converting airborne hyperspectral spectrometer data to reflectance factors were characterized and compared. The “reflectance mode (RM)” method, which calibrates a spectrometer against a white reference panel prior to mounting on an aircraft, resulted in spectral reflectance retrievals that were biased and distorted. The magnitudes of these bias errors and distortions varied significantly, depending on time of day and length of the flight campaign. The “linear-interpolation (LI)” method, which converts airborne spectrometer data by taking a ratio of linearly-interpolated reference values from the preflight and post-flight reference panel readings, resulted in precise, but inaccurate reflectance retrievals. These reflectance spectra were not distorted, but were subject to bias errors of varying magnitudes dependent on the flight duration length. The “continuous panel (CP)” method uses a multi-band radiometer to obtain continuous measurements over a reference panel throughout the flight campaign, in order to adjust the magnitudes of the linear-interpolated reference values from the preflight and post-flight reference panel readings. Airborne hyperspectral reflectance retrievals obtained using this method were found to be the most accurate and reliable reflectance calibration method. The performances of the CP method in retrieving accurate reflectance factors were consistent throughout time of day and for various flight durations. Based on the dataset analyzed in this study, the uncertainty of the CP method has been estimated to be 0.0025 ± 0.0005 reflectance units for the wavelength regions not affected by atmospheric absorptions. The RM method can produce reasonable results only for a very short-term flight (e.g., < 15 minutes) conducted around a local solar noon. The flight duration should be kept shorter than 30 minutes for the LI method to produce results with reasonable accuracies. An important advantage of the CP method is that the method can be used for long-duration flight campaigns (e.g., 1-2 hours). Although this study focused on reflectance calibration of airborne spectrometer data, the methods evaluated in this study and the results obtained are directly applicable to ground spectrometer measurements. Molecular Diversity Preservation International (MDPI) 2009-02-03 /pmc/articles/PMC3280831/ /pubmed/22399939 http://dx.doi.org/10.3390/s90200794 Text en © 2009 by the authors; licensee Molecular Diversity Preservation International, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Miura, Tomoaki
Huete, Alfredo R.
Performance of Three Reflectance Calibration Methods for Airborne Hyperspectral Spectrometer Data
title Performance of Three Reflectance Calibration Methods for Airborne Hyperspectral Spectrometer Data
title_full Performance of Three Reflectance Calibration Methods for Airborne Hyperspectral Spectrometer Data
title_fullStr Performance of Three Reflectance Calibration Methods for Airborne Hyperspectral Spectrometer Data
title_full_unstemmed Performance of Three Reflectance Calibration Methods for Airborne Hyperspectral Spectrometer Data
title_short Performance of Three Reflectance Calibration Methods for Airborne Hyperspectral Spectrometer Data
title_sort performance of three reflectance calibration methods for airborne hyperspectral spectrometer data
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3280831/
https://www.ncbi.nlm.nih.gov/pubmed/22399939
http://dx.doi.org/10.3390/s90200794
work_keys_str_mv AT miuratomoaki performanceofthreereflectancecalibrationmethodsforairbornehyperspectralspectrometerdata
AT huetealfredor performanceofthreereflectancecalibrationmethodsforairbornehyperspectralspectrometerdata