Comparison of the accuracy of neutrophil CD64 and C-reactive protein as a single test for the early detection of neonatal sepsis

PURPOSE: Early identification of neonatal sepsis is a global issue because of limitations in diagnostic procedures. The objective of this study was to compare the diagnostic accuracy of neutrophil CD64 and C-reactive protein (CRP) as a single test for the early detection of neonatal sepsis. METHODS:...

Descripción completa

Detalles Bibliográficos
Autores principales: Choo, Young Kwang, Cho, Hyun-Seok, Seo, In Bum, Lee, Hyeon-Soo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Pediatric Society 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3282213/
https://www.ncbi.nlm.nih.gov/pubmed/22359525
http://dx.doi.org/10.3345/kjp.2012.55.1.11
_version_ 1782224047530049536
author Choo, Young Kwang
Cho, Hyun-Seok
Seo, In Bum
Lee, Hyeon-Soo
author_facet Choo, Young Kwang
Cho, Hyun-Seok
Seo, In Bum
Lee, Hyeon-Soo
author_sort Choo, Young Kwang
collection PubMed
description PURPOSE: Early identification of neonatal sepsis is a global issue because of limitations in diagnostic procedures. The objective of this study was to compare the diagnostic accuracy of neutrophil CD64 and C-reactive protein (CRP) as a single test for the early detection of neonatal sepsis. METHODS: A prospective study enrolled newborns with documented sepsis (n=11), clinical sepsis (n=12) and control newborns (n=14). CRP, neutrophil CD64, complete blood counts and blood culture were taken at the time of the suspected sepsis for the documented or clinical group and at the time of venipuncture for laboratory tests in control newborns. Neutrophil CD64 was analyzed by flow cytometry. RESULTS: CD64 was significantly elevated in the groups with documented or clinical sepsis, whereas CRP was not significantly increased compared with controls. For documented sepsis, CD64 and CRP had a sensitivity of 91% and 9%, a specificity of 83% and 83%, a positive predictive value of 83% and 33% and a negative predictive value of 91% and 50%, respectively, with a cutoff value of 3.0 mg/dL for CD64 and 1.0 mg/dL for CRP. The area under the receiver-operating characteristic curves for CD64 index and CRP were 0.955 and 0.527 (P<0.01), respectively. CONCLUSION: These preliminary data show that diagnostic accuracy of CD64 is superior to CRP when measured at the time of suspected sepsis, which implies that CD64 is a more reliable marker for the early identification of neonatal sepsis as a single determination compared with CRP.
format Online
Article
Text
id pubmed-3282213
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher The Korean Pediatric Society
record_format MEDLINE/PubMed
spelling pubmed-32822132012-02-22 Comparison of the accuracy of neutrophil CD64 and C-reactive protein as a single test for the early detection of neonatal sepsis Choo, Young Kwang Cho, Hyun-Seok Seo, In Bum Lee, Hyeon-Soo Korean J Pediatr Original Article PURPOSE: Early identification of neonatal sepsis is a global issue because of limitations in diagnostic procedures. The objective of this study was to compare the diagnostic accuracy of neutrophil CD64 and C-reactive protein (CRP) as a single test for the early detection of neonatal sepsis. METHODS: A prospective study enrolled newborns with documented sepsis (n=11), clinical sepsis (n=12) and control newborns (n=14). CRP, neutrophil CD64, complete blood counts and blood culture were taken at the time of the suspected sepsis for the documented or clinical group and at the time of venipuncture for laboratory tests in control newborns. Neutrophil CD64 was analyzed by flow cytometry. RESULTS: CD64 was significantly elevated in the groups with documented or clinical sepsis, whereas CRP was not significantly increased compared with controls. For documented sepsis, CD64 and CRP had a sensitivity of 91% and 9%, a specificity of 83% and 83%, a positive predictive value of 83% and 33% and a negative predictive value of 91% and 50%, respectively, with a cutoff value of 3.0 mg/dL for CD64 and 1.0 mg/dL for CRP. The area under the receiver-operating characteristic curves for CD64 index and CRP were 0.955 and 0.527 (P<0.01), respectively. CONCLUSION: These preliminary data show that diagnostic accuracy of CD64 is superior to CRP when measured at the time of suspected sepsis, which implies that CD64 is a more reliable marker for the early identification of neonatal sepsis as a single determination compared with CRP. The Korean Pediatric Society 2012-01 2012-01-31 /pmc/articles/PMC3282213/ /pubmed/22359525 http://dx.doi.org/10.3345/kjp.2012.55.1.11 Text en Copyright © 2012 by The Korean Pediatric Society http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Choo, Young Kwang
Cho, Hyun-Seok
Seo, In Bum
Lee, Hyeon-Soo
Comparison of the accuracy of neutrophil CD64 and C-reactive protein as a single test for the early detection of neonatal sepsis
title Comparison of the accuracy of neutrophil CD64 and C-reactive protein as a single test for the early detection of neonatal sepsis
title_full Comparison of the accuracy of neutrophil CD64 and C-reactive protein as a single test for the early detection of neonatal sepsis
title_fullStr Comparison of the accuracy of neutrophil CD64 and C-reactive protein as a single test for the early detection of neonatal sepsis
title_full_unstemmed Comparison of the accuracy of neutrophil CD64 and C-reactive protein as a single test for the early detection of neonatal sepsis
title_short Comparison of the accuracy of neutrophil CD64 and C-reactive protein as a single test for the early detection of neonatal sepsis
title_sort comparison of the accuracy of neutrophil cd64 and c-reactive protein as a single test for the early detection of neonatal sepsis
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3282213/
https://www.ncbi.nlm.nih.gov/pubmed/22359525
http://dx.doi.org/10.3345/kjp.2012.55.1.11
work_keys_str_mv AT chooyoungkwang comparisonoftheaccuracyofneutrophilcd64andcreactiveproteinasasingletestfortheearlydetectionofneonatalsepsis
AT chohyunseok comparisonoftheaccuracyofneutrophilcd64andcreactiveproteinasasingletestfortheearlydetectionofneonatalsepsis
AT seoinbum comparisonoftheaccuracyofneutrophilcd64andcreactiveproteinasasingletestfortheearlydetectionofneonatalsepsis
AT leehyeonsoo comparisonoftheaccuracyofneutrophilcd64andcreactiveproteinasasingletestfortheearlydetectionofneonatalsepsis