Cargando…

Determining entropy values equivalent to the bispectral index values during sevoflurane anaesthesia

INTRODUCTION: We aimed to identify the entropy levels that would be equivalent to the bispectral index (BIS) levels in sevoflurane anaesthesia in patients who are to undergo elective lumbar disc surgery. MATERIAL AND METHODS: Thirty cases in ASA groups I-II who underwent lumbar disc surgery under ge...

Descripción completa

Detalles Bibliográficos
Autores principales: Balcı, Canan, Karabekir, Hamit, Sivaci, Remziye
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3282514/
https://www.ncbi.nlm.nih.gov/pubmed/22371773
http://dx.doi.org/10.5114/aoms.2010.14257
_version_ 1782224079549366272
author Balcı, Canan
Karabekir, Hamit
Sivaci, Remziye
author_facet Balcı, Canan
Karabekir, Hamit
Sivaci, Remziye
author_sort Balcı, Canan
collection PubMed
description INTRODUCTION: We aimed to identify the entropy levels that would be equivalent to the bispectral index (BIS) levels in sevoflurane anaesthesia in patients who are to undergo elective lumbar disc surgery. MATERIAL AND METHODS: Thirty cases in ASA groups I-II who underwent lumbar disc surgery under general anaesthesia were included in our study after obtaining the consent of the patients and Ethics Committee of our medical school between January 1, 2005 and October 30, 2006. BIS and entropy electrodes were applied at the same time in 30 cases in the study group. The depth of the anaesthesia was regulated so that 10 min after beginning the general anaesthesia the BIS values were between 40 and 60. At the same time equivalent entropy values corresponding to BIS values were obtained. RESULTS: At the end of the study, entropy values corresponding to general anaesthesia BIS values were identified. General anaesthesia BIS and RE/SE values at 10 min were lower than the values of the control, which was statistically significant (p < 0.05). Equivalent entropy values were obtained lower than the BIS values during general anaesthesia and these values were found to be statistically significant (p < 0.05). The blood pressure (BP) values obtained were very low at equivalent BIS values and when these BP values were compared with the initial BP values they were found to be statistically significant (p < 0.05). CONCLUSIONS: Based on this observation, we think that general anaesthetic agents that might cause severe hypotension could be more safely administered under entropy monitoring.
format Online
Article
Text
id pubmed-3282514
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-32825142012-02-27 Determining entropy values equivalent to the bispectral index values during sevoflurane anaesthesia Balcı, Canan Karabekir, Hamit Sivaci, Remziye Arch Med Sci Clinical Research INTRODUCTION: We aimed to identify the entropy levels that would be equivalent to the bispectral index (BIS) levels in sevoflurane anaesthesia in patients who are to undergo elective lumbar disc surgery. MATERIAL AND METHODS: Thirty cases in ASA groups I-II who underwent lumbar disc surgery under general anaesthesia were included in our study after obtaining the consent of the patients and Ethics Committee of our medical school between January 1, 2005 and October 30, 2006. BIS and entropy electrodes were applied at the same time in 30 cases in the study group. The depth of the anaesthesia was regulated so that 10 min after beginning the general anaesthesia the BIS values were between 40 and 60. At the same time equivalent entropy values corresponding to BIS values were obtained. RESULTS: At the end of the study, entropy values corresponding to general anaesthesia BIS values were identified. General anaesthesia BIS and RE/SE values at 10 min were lower than the values of the control, which was statistically significant (p < 0.05). Equivalent entropy values were obtained lower than the BIS values during general anaesthesia and these values were found to be statistically significant (p < 0.05). The blood pressure (BP) values obtained were very low at equivalent BIS values and when these BP values were compared with the initial BP values they were found to be statistically significant (p < 0.05). CONCLUSIONS: Based on this observation, we think that general anaesthetic agents that might cause severe hypotension could be more safely administered under entropy monitoring. Termedia Publishing House 2010-06-30 2010-06-30 /pmc/articles/PMC3282514/ /pubmed/22371773 http://dx.doi.org/10.5114/aoms.2010.14257 Text en Copyright © 2010 Termedia & Banach http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Research
Balcı, Canan
Karabekir, Hamit
Sivaci, Remziye
Determining entropy values equivalent to the bispectral index values during sevoflurane anaesthesia
title Determining entropy values equivalent to the bispectral index values during sevoflurane anaesthesia
title_full Determining entropy values equivalent to the bispectral index values during sevoflurane anaesthesia
title_fullStr Determining entropy values equivalent to the bispectral index values during sevoflurane anaesthesia
title_full_unstemmed Determining entropy values equivalent to the bispectral index values during sevoflurane anaesthesia
title_short Determining entropy values equivalent to the bispectral index values during sevoflurane anaesthesia
title_sort determining entropy values equivalent to the bispectral index values during sevoflurane anaesthesia
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3282514/
https://www.ncbi.nlm.nih.gov/pubmed/22371773
http://dx.doi.org/10.5114/aoms.2010.14257
work_keys_str_mv AT balcıcanan determiningentropyvaluesequivalenttothebispectralindexvaluesduringsevofluraneanaesthesia
AT karabekirhamit determiningentropyvaluesequivalenttothebispectralindexvaluesduringsevofluraneanaesthesia
AT sivaciremziye determiningentropyvaluesequivalenttothebispectralindexvaluesduringsevofluraneanaesthesia