Use of combined maximum and minimum intensity projections to determine internal target volume in 4-dimensional CT scans for hepatic malignancies

BACKGROUND: To evaluate the accuracy of the combined maximum and minimum intensity projection-based internal target volume (ITV) delineation in 4-dimensional (4D) CT scans for liver malignancies. METHODS: 4D CT with synchronized IV contrast data were acquired from 15 liver cancer patients (4 hepatoc...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Jin, Wang, Jia-Zhou, Zhao, Jian-Dong, Xu, Zhi-Yong, Jiang, Guo-Liang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3283494/
https://www.ncbi.nlm.nih.gov/pubmed/22284745
http://dx.doi.org/10.1186/1748-717X-7-11
_version_ 1782224197334859776
author Liu, Jin
Wang, Jia-Zhou
Zhao, Jian-Dong
Xu, Zhi-Yong
Jiang, Guo-Liang
author_facet Liu, Jin
Wang, Jia-Zhou
Zhao, Jian-Dong
Xu, Zhi-Yong
Jiang, Guo-Liang
author_sort Liu, Jin
collection PubMed
description BACKGROUND: To evaluate the accuracy of the combined maximum and minimum intensity projection-based internal target volume (ITV) delineation in 4-dimensional (4D) CT scans for liver malignancies. METHODS: 4D CT with synchronized IV contrast data were acquired from 15 liver cancer patients (4 hepatocellular carcinomas; 11 hepatic metastases). We used five approaches to determine ITVs: (1). ITV(AllPhases): contouring gross tumor volume (GTV) on each of 10 respiratory phases of 4D CT data set and combining these GTVs; (2). ITV(2Phase): contouring GTV on CT of the peak inhale phase (0% phase) and the peak exhale phase (50%) and then combining the two; (3). ITV(MIP): contouring GTV on MIP with modifications based on physician's visual verification of contours in each respiratory phase; (4). ITV(MinIP): contouring GTV on MinIP with modification by physician; (5). ITV(2M): combining ITV(MIP )and ITV(MinIP). ITV(AllPhases )was taken as the reference ITV, and the metrics used for comparison were: matching index (MI), under- and over-estimated volume (V(under )and V(over)). RESULTS: 4D CT images were successfully acquired from 15 patients and tumor margins were clearly discernable in all patients. There were 9 cases of low density and 6, mixed on CT images. After comparisons of metrics, the tool of ITV(2M )was the most appropriate to contour ITV for liver malignancies with the highest MI of 0.93 ± 0.04 and the lowest proportion of V(under )(0.07 ± 0.04). Moreover, tumor volume, target motion three-dimensionally and ratio of tumor vertical diameter over tumor motion magnitude in cranio-caudal direction did not significantly influence the values of MI and proportion of V(under). CONCLUSION: The tool of ITV(2M )is recommended as a reliable method for generating ITVs from 4D CT data sets in liver cancer.
format Online
Article
Text
id pubmed-3283494
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-32834942012-02-22 Use of combined maximum and minimum intensity projections to determine internal target volume in 4-dimensional CT scans for hepatic malignancies Liu, Jin Wang, Jia-Zhou Zhao, Jian-Dong Xu, Zhi-Yong Jiang, Guo-Liang Radiat Oncol Research BACKGROUND: To evaluate the accuracy of the combined maximum and minimum intensity projection-based internal target volume (ITV) delineation in 4-dimensional (4D) CT scans for liver malignancies. METHODS: 4D CT with synchronized IV contrast data were acquired from 15 liver cancer patients (4 hepatocellular carcinomas; 11 hepatic metastases). We used five approaches to determine ITVs: (1). ITV(AllPhases): contouring gross tumor volume (GTV) on each of 10 respiratory phases of 4D CT data set and combining these GTVs; (2). ITV(2Phase): contouring GTV on CT of the peak inhale phase (0% phase) and the peak exhale phase (50%) and then combining the two; (3). ITV(MIP): contouring GTV on MIP with modifications based on physician's visual verification of contours in each respiratory phase; (4). ITV(MinIP): contouring GTV on MinIP with modification by physician; (5). ITV(2M): combining ITV(MIP )and ITV(MinIP). ITV(AllPhases )was taken as the reference ITV, and the metrics used for comparison were: matching index (MI), under- and over-estimated volume (V(under )and V(over)). RESULTS: 4D CT images were successfully acquired from 15 patients and tumor margins were clearly discernable in all patients. There were 9 cases of low density and 6, mixed on CT images. After comparisons of metrics, the tool of ITV(2M )was the most appropriate to contour ITV for liver malignancies with the highest MI of 0.93 ± 0.04 and the lowest proportion of V(under )(0.07 ± 0.04). Moreover, tumor volume, target motion three-dimensionally and ratio of tumor vertical diameter over tumor motion magnitude in cranio-caudal direction did not significantly influence the values of MI and proportion of V(under). CONCLUSION: The tool of ITV(2M )is recommended as a reliable method for generating ITVs from 4D CT data sets in liver cancer. BioMed Central 2012-01-30 /pmc/articles/PMC3283494/ /pubmed/22284745 http://dx.doi.org/10.1186/1748-717X-7-11 Text en Copyright ©2012 Liu et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Liu, Jin
Wang, Jia-Zhou
Zhao, Jian-Dong
Xu, Zhi-Yong
Jiang, Guo-Liang
Use of combined maximum and minimum intensity projections to determine internal target volume in 4-dimensional CT scans for hepatic malignancies
title Use of combined maximum and minimum intensity projections to determine internal target volume in 4-dimensional CT scans for hepatic malignancies
title_full Use of combined maximum and minimum intensity projections to determine internal target volume in 4-dimensional CT scans for hepatic malignancies
title_fullStr Use of combined maximum and minimum intensity projections to determine internal target volume in 4-dimensional CT scans for hepatic malignancies
title_full_unstemmed Use of combined maximum and minimum intensity projections to determine internal target volume in 4-dimensional CT scans for hepatic malignancies
title_short Use of combined maximum and minimum intensity projections to determine internal target volume in 4-dimensional CT scans for hepatic malignancies
title_sort use of combined maximum and minimum intensity projections to determine internal target volume in 4-dimensional ct scans for hepatic malignancies
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3283494/
https://www.ncbi.nlm.nih.gov/pubmed/22284745
http://dx.doi.org/10.1186/1748-717X-7-11
work_keys_str_mv AT liujin useofcombinedmaximumandminimumintensityprojectionstodetermineinternaltargetvolumein4dimensionalctscansforhepaticmalignancies
AT wangjiazhou useofcombinedmaximumandminimumintensityprojectionstodetermineinternaltargetvolumein4dimensionalctscansforhepaticmalignancies
AT zhaojiandong useofcombinedmaximumandminimumintensityprojectionstodetermineinternaltargetvolumein4dimensionalctscansforhepaticmalignancies
AT xuzhiyong useofcombinedmaximumandminimumintensityprojectionstodetermineinternaltargetvolumein4dimensionalctscansforhepaticmalignancies
AT jiangguoliang useofcombinedmaximumandminimumintensityprojectionstodetermineinternaltargetvolumein4dimensionalctscansforhepaticmalignancies