Cargando…

Exploiting Magnetic Resonance Angiography Imaging Improves Model Estimation of BOLD Signal

The change of BOLD signal relies heavily upon the resting blood volume fraction ([Image: see text]) associated with regional vasculature. However, existing hemodynamic data assimilation studies pretermit such concern. They simply assign the value in a physiologically plausible range to get over ill-...

Descripción completa

Detalles Bibliográficos
Autores principales: Hu, Zhenghui, Liu, Cong, Shi, Pengcheng, Liu, Huafeng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3285158/
https://www.ncbi.nlm.nih.gov/pubmed/22384043
http://dx.doi.org/10.1371/journal.pone.0031612
_version_ 1782224461755318272
author Hu, Zhenghui
Liu, Cong
Shi, Pengcheng
Liu, Huafeng
author_facet Hu, Zhenghui
Liu, Cong
Shi, Pengcheng
Liu, Huafeng
author_sort Hu, Zhenghui
collection PubMed
description The change of BOLD signal relies heavily upon the resting blood volume fraction ([Image: see text]) associated with regional vasculature. However, existing hemodynamic data assimilation studies pretermit such concern. They simply assign the value in a physiologically plausible range to get over ill-conditioning of the assimilation problem and fail to explore actual [Image: see text]. Such performance might lead to unreliable model estimation. In this work, we present the first exploration of the influence of [Image: see text] on fMRI data assimilation, where actual [Image: see text] within a given cortical area was calibrated by an MR angiography experiment and then was augmented into the assimilation scheme. We have investigated the impact of [Image: see text] on single-region data assimilation and multi-region data assimilation (dynamic cause modeling, DCM) in a classical flashing checkerboard experiment. Results show that the employment of an assumed [Image: see text] in fMRI data assimilation is only suitable for fMRI signal reconstruction and activation detection grounded on this signal, and not suitable for estimation of unobserved states and effective connectivity study. We thereby argue that introducing physically realistic [Image: see text] in the assimilation process may provide more reliable estimation of physiological information, which contributes to a better understanding of the underlying hemodynamic processes. Such an effort is valuable and should be well appreciated.
format Online
Article
Text
id pubmed-3285158
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-32851582012-03-01 Exploiting Magnetic Resonance Angiography Imaging Improves Model Estimation of BOLD Signal Hu, Zhenghui Liu, Cong Shi, Pengcheng Liu, Huafeng PLoS One Research Article The change of BOLD signal relies heavily upon the resting blood volume fraction ([Image: see text]) associated with regional vasculature. However, existing hemodynamic data assimilation studies pretermit such concern. They simply assign the value in a physiologically plausible range to get over ill-conditioning of the assimilation problem and fail to explore actual [Image: see text]. Such performance might lead to unreliable model estimation. In this work, we present the first exploration of the influence of [Image: see text] on fMRI data assimilation, where actual [Image: see text] within a given cortical area was calibrated by an MR angiography experiment and then was augmented into the assimilation scheme. We have investigated the impact of [Image: see text] on single-region data assimilation and multi-region data assimilation (dynamic cause modeling, DCM) in a classical flashing checkerboard experiment. Results show that the employment of an assumed [Image: see text] in fMRI data assimilation is only suitable for fMRI signal reconstruction and activation detection grounded on this signal, and not suitable for estimation of unobserved states and effective connectivity study. We thereby argue that introducing physically realistic [Image: see text] in the assimilation process may provide more reliable estimation of physiological information, which contributes to a better understanding of the underlying hemodynamic processes. Such an effort is valuable and should be well appreciated. Public Library of Science 2012-02-22 /pmc/articles/PMC3285158/ /pubmed/22384043 http://dx.doi.org/10.1371/journal.pone.0031612 Text en Hu et al. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Hu, Zhenghui
Liu, Cong
Shi, Pengcheng
Liu, Huafeng
Exploiting Magnetic Resonance Angiography Imaging Improves Model Estimation of BOLD Signal
title Exploiting Magnetic Resonance Angiography Imaging Improves Model Estimation of BOLD Signal
title_full Exploiting Magnetic Resonance Angiography Imaging Improves Model Estimation of BOLD Signal
title_fullStr Exploiting Magnetic Resonance Angiography Imaging Improves Model Estimation of BOLD Signal
title_full_unstemmed Exploiting Magnetic Resonance Angiography Imaging Improves Model Estimation of BOLD Signal
title_short Exploiting Magnetic Resonance Angiography Imaging Improves Model Estimation of BOLD Signal
title_sort exploiting magnetic resonance angiography imaging improves model estimation of bold signal
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3285158/
https://www.ncbi.nlm.nih.gov/pubmed/22384043
http://dx.doi.org/10.1371/journal.pone.0031612
work_keys_str_mv AT huzhenghui exploitingmagneticresonanceangiographyimagingimprovesmodelestimationofboldsignal
AT liucong exploitingmagneticresonanceangiographyimagingimprovesmodelestimationofboldsignal
AT shipengcheng exploitingmagneticresonanceangiographyimagingimprovesmodelestimationofboldsignal
AT liuhuafeng exploitingmagneticresonanceangiographyimagingimprovesmodelestimationofboldsignal