Cargando…
Exploiting Magnetic Resonance Angiography Imaging Improves Model Estimation of BOLD Signal
The change of BOLD signal relies heavily upon the resting blood volume fraction ([Image: see text]) associated with regional vasculature. However, existing hemodynamic data assimilation studies pretermit such concern. They simply assign the value in a physiologically plausible range to get over ill-...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3285158/ https://www.ncbi.nlm.nih.gov/pubmed/22384043 http://dx.doi.org/10.1371/journal.pone.0031612 |
_version_ | 1782224461755318272 |
---|---|
author | Hu, Zhenghui Liu, Cong Shi, Pengcheng Liu, Huafeng |
author_facet | Hu, Zhenghui Liu, Cong Shi, Pengcheng Liu, Huafeng |
author_sort | Hu, Zhenghui |
collection | PubMed |
description | The change of BOLD signal relies heavily upon the resting blood volume fraction ([Image: see text]) associated with regional vasculature. However, existing hemodynamic data assimilation studies pretermit such concern. They simply assign the value in a physiologically plausible range to get over ill-conditioning of the assimilation problem and fail to explore actual [Image: see text]. Such performance might lead to unreliable model estimation. In this work, we present the first exploration of the influence of [Image: see text] on fMRI data assimilation, where actual [Image: see text] within a given cortical area was calibrated by an MR angiography experiment and then was augmented into the assimilation scheme. We have investigated the impact of [Image: see text] on single-region data assimilation and multi-region data assimilation (dynamic cause modeling, DCM) in a classical flashing checkerboard experiment. Results show that the employment of an assumed [Image: see text] in fMRI data assimilation is only suitable for fMRI signal reconstruction and activation detection grounded on this signal, and not suitable for estimation of unobserved states and effective connectivity study. We thereby argue that introducing physically realistic [Image: see text] in the assimilation process may provide more reliable estimation of physiological information, which contributes to a better understanding of the underlying hemodynamic processes. Such an effort is valuable and should be well appreciated. |
format | Online Article Text |
id | pubmed-3285158 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-32851582012-03-01 Exploiting Magnetic Resonance Angiography Imaging Improves Model Estimation of BOLD Signal Hu, Zhenghui Liu, Cong Shi, Pengcheng Liu, Huafeng PLoS One Research Article The change of BOLD signal relies heavily upon the resting blood volume fraction ([Image: see text]) associated with regional vasculature. However, existing hemodynamic data assimilation studies pretermit such concern. They simply assign the value in a physiologically plausible range to get over ill-conditioning of the assimilation problem and fail to explore actual [Image: see text]. Such performance might lead to unreliable model estimation. In this work, we present the first exploration of the influence of [Image: see text] on fMRI data assimilation, where actual [Image: see text] within a given cortical area was calibrated by an MR angiography experiment and then was augmented into the assimilation scheme. We have investigated the impact of [Image: see text] on single-region data assimilation and multi-region data assimilation (dynamic cause modeling, DCM) in a classical flashing checkerboard experiment. Results show that the employment of an assumed [Image: see text] in fMRI data assimilation is only suitable for fMRI signal reconstruction and activation detection grounded on this signal, and not suitable for estimation of unobserved states and effective connectivity study. We thereby argue that introducing physically realistic [Image: see text] in the assimilation process may provide more reliable estimation of physiological information, which contributes to a better understanding of the underlying hemodynamic processes. Such an effort is valuable and should be well appreciated. Public Library of Science 2012-02-22 /pmc/articles/PMC3285158/ /pubmed/22384043 http://dx.doi.org/10.1371/journal.pone.0031612 Text en Hu et al. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Hu, Zhenghui Liu, Cong Shi, Pengcheng Liu, Huafeng Exploiting Magnetic Resonance Angiography Imaging Improves Model Estimation of BOLD Signal |
title | Exploiting Magnetic Resonance Angiography Imaging Improves Model Estimation of BOLD Signal |
title_full | Exploiting Magnetic Resonance Angiography Imaging Improves Model Estimation of BOLD Signal |
title_fullStr | Exploiting Magnetic Resonance Angiography Imaging Improves Model Estimation of BOLD Signal |
title_full_unstemmed | Exploiting Magnetic Resonance Angiography Imaging Improves Model Estimation of BOLD Signal |
title_short | Exploiting Magnetic Resonance Angiography Imaging Improves Model Estimation of BOLD Signal |
title_sort | exploiting magnetic resonance angiography imaging improves model estimation of bold signal |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3285158/ https://www.ncbi.nlm.nih.gov/pubmed/22384043 http://dx.doi.org/10.1371/journal.pone.0031612 |
work_keys_str_mv | AT huzhenghui exploitingmagneticresonanceangiographyimagingimprovesmodelestimationofboldsignal AT liucong exploitingmagneticresonanceangiographyimagingimprovesmodelestimationofboldsignal AT shipengcheng exploitingmagneticresonanceangiographyimagingimprovesmodelestimationofboldsignal AT liuhuafeng exploitingmagneticresonanceangiographyimagingimprovesmodelestimationofboldsignal |