Cargando…

The Effect of Contrast Medium SonoVue(®) on the Electric Charge Density of Blood Cells

The effect of contrast medium SonoVue® on the electric charge density of blood cells (erythrocytes and thrombocytes) was measured using a microelectrophoretic method. We examined the effect of adsorbed H(+) and OH(−) ions on the surface charge of erythrocytes or thrombocytes. Surface charge density...

Descripción completa

Detalles Bibliográficos
Autores principales: Petelska, Aneta D., Janica, Jacek R., Kotynska, Joanna, Łebkowska, Urszula, Figaszewski, Zbigniew A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer-Verlag 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3285753/
https://www.ncbi.nlm.nih.gov/pubmed/22113525
http://dx.doi.org/10.1007/s00232-011-9409-z
_version_ 1782224520628666368
author Petelska, Aneta D.
Janica, Jacek R.
Kotynska, Joanna
Łebkowska, Urszula
Figaszewski, Zbigniew A.
author_facet Petelska, Aneta D.
Janica, Jacek R.
Kotynska, Joanna
Łebkowska, Urszula
Figaszewski, Zbigniew A.
author_sort Petelska, Aneta D.
collection PubMed
description The effect of contrast medium SonoVue® on the electric charge density of blood cells (erythrocytes and thrombocytes) was measured using a microelectrophoretic method. We examined the effect of adsorbed H(+) and OH(−) ions on the surface charge of erythrocytes or thrombocytes. Surface charge density values were determined from electrophoretic mobility measurements of blood cells performed at various pH levels. The interaction between solution ions and the erythrocyte’s or thrombocyte’s surface was described by a four-component equilibrium model. The agreement between the experimental and theoretical charge variation curves of the erythrocytes and thrombocytes was good at pH 2–9. The deviation observed at a higher pH may be caused by disregarding interactions between the functional groups of blood cells.
format Online
Article
Text
id pubmed-3285753
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Springer-Verlag
record_format MEDLINE/PubMed
spelling pubmed-32857532012-03-08 The Effect of Contrast Medium SonoVue(®) on the Electric Charge Density of Blood Cells Petelska, Aneta D. Janica, Jacek R. Kotynska, Joanna Łebkowska, Urszula Figaszewski, Zbigniew A. J Membr Biol Article The effect of contrast medium SonoVue® on the electric charge density of blood cells (erythrocytes and thrombocytes) was measured using a microelectrophoretic method. We examined the effect of adsorbed H(+) and OH(−) ions on the surface charge of erythrocytes or thrombocytes. Surface charge density values were determined from electrophoretic mobility measurements of blood cells performed at various pH levels. The interaction between solution ions and the erythrocyte’s or thrombocyte’s surface was described by a four-component equilibrium model. The agreement between the experimental and theoretical charge variation curves of the erythrocytes and thrombocytes was good at pH 2–9. The deviation observed at a higher pH may be caused by disregarding interactions between the functional groups of blood cells. Springer-Verlag 2011-11-24 2012 /pmc/articles/PMC3285753/ /pubmed/22113525 http://dx.doi.org/10.1007/s00232-011-9409-z Text en © The Author(s) 2011 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
spellingShingle Article
Petelska, Aneta D.
Janica, Jacek R.
Kotynska, Joanna
Łebkowska, Urszula
Figaszewski, Zbigniew A.
The Effect of Contrast Medium SonoVue(®) on the Electric Charge Density of Blood Cells
title The Effect of Contrast Medium SonoVue(®) on the Electric Charge Density of Blood Cells
title_full The Effect of Contrast Medium SonoVue(®) on the Electric Charge Density of Blood Cells
title_fullStr The Effect of Contrast Medium SonoVue(®) on the Electric Charge Density of Blood Cells
title_full_unstemmed The Effect of Contrast Medium SonoVue(®) on the Electric Charge Density of Blood Cells
title_short The Effect of Contrast Medium SonoVue(®) on the Electric Charge Density of Blood Cells
title_sort effect of contrast medium sonovue(®) on the electric charge density of blood cells
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3285753/
https://www.ncbi.nlm.nih.gov/pubmed/22113525
http://dx.doi.org/10.1007/s00232-011-9409-z
work_keys_str_mv AT petelskaanetad theeffectofcontrastmediumsonovueontheelectricchargedensityofbloodcells
AT janicajacekr theeffectofcontrastmediumsonovueontheelectricchargedensityofbloodcells
AT kotynskajoanna theeffectofcontrastmediumsonovueontheelectricchargedensityofbloodcells
AT łebkowskaurszula theeffectofcontrastmediumsonovueontheelectricchargedensityofbloodcells
AT figaszewskizbigniewa theeffectofcontrastmediumsonovueontheelectricchargedensityofbloodcells
AT petelskaanetad effectofcontrastmediumsonovueontheelectricchargedensityofbloodcells
AT janicajacekr effectofcontrastmediumsonovueontheelectricchargedensityofbloodcells
AT kotynskajoanna effectofcontrastmediumsonovueontheelectricchargedensityofbloodcells
AT łebkowskaurszula effectofcontrastmediumsonovueontheelectricchargedensityofbloodcells
AT figaszewskizbigniewa effectofcontrastmediumsonovueontheelectricchargedensityofbloodcells