Cargando…
Sample Preparation and Liquid Chromatography-Tandem Mass Spectrometry for Multiple Steroids in Mammalian and Avian Circulation
Blood samples from wild mammals and birds are often limited in volume, allowing researchers to quantify only one or two steroids from a single sample by immunoassays. In addition, wildlife serum or plasma samples are often lipemic, necessitating stringent sample preparation. Here, we validated sampl...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3288106/ https://www.ncbi.nlm.nih.gov/pubmed/22384262 http://dx.doi.org/10.1371/journal.pone.0032496 |
_version_ | 1782224806695927808 |
---|---|
author | Koren, Lee Ng, Ella S. M. Soma, Kiran K. Wynne-Edwards, Katherine E. |
author_facet | Koren, Lee Ng, Ella S. M. Soma, Kiran K. Wynne-Edwards, Katherine E. |
author_sort | Koren, Lee |
collection | PubMed |
description | Blood samples from wild mammals and birds are often limited in volume, allowing researchers to quantify only one or two steroids from a single sample by immunoassays. In addition, wildlife serum or plasma samples are often lipemic, necessitating stringent sample preparation. Here, we validated sample preparation for simultaneous liquid chromatography – tandem mass spectrometry (LC-MS/MS) quantitation of cortisol, corticosterone, 11-deoxycortisol, dehydroepiandrosterone (DHEA), 17β-estradiol, progesterone, 17α-hydroxyprogesterone and testosterone from diverse mammalian (7 species) and avian (5 species) samples. Using 100 µL of serum or plasma, we quantified (signal-to-noise (S/N) ratio ≥10) 4–7 steroids depending on the species and sample, without derivatization. Steroids were extracted from serum or plasma using automated solid-phase extraction where samples were loaded onto C18 columns, washed with water and hexane, and then eluted with ethyl acetate. Quantitation by LC-MS/MS was done in positive ion, multiple reaction-monitoring (MRM) mode with an atmospheric pressure chemical ionization (APCI) source and heated nebulizer (500°C). Deuterated steroids served as internal standards and run time was 15 minutes. Extraction recoveries were 87–101% for the 8 analytes, and all intra- and inter-run CVs were ≤8.25%. This quantitation method yields good recoveries with variable lipid-content samples, avoids antibody cross-reactivity issues, and delivers results for multiple steroids. Thus, this method can enrich datasets by providing simultaneous quantitation of multiple steroids, and allow researchers to reimagine the hypotheses that could be tested with their volume-limited, lipemic, wildlife samples. |
format | Online Article Text |
id | pubmed-3288106 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-32881062012-03-01 Sample Preparation and Liquid Chromatography-Tandem Mass Spectrometry for Multiple Steroids in Mammalian and Avian Circulation Koren, Lee Ng, Ella S. M. Soma, Kiran K. Wynne-Edwards, Katherine E. PLoS One Research Article Blood samples from wild mammals and birds are often limited in volume, allowing researchers to quantify only one or two steroids from a single sample by immunoassays. In addition, wildlife serum or plasma samples are often lipemic, necessitating stringent sample preparation. Here, we validated sample preparation for simultaneous liquid chromatography – tandem mass spectrometry (LC-MS/MS) quantitation of cortisol, corticosterone, 11-deoxycortisol, dehydroepiandrosterone (DHEA), 17β-estradiol, progesterone, 17α-hydroxyprogesterone and testosterone from diverse mammalian (7 species) and avian (5 species) samples. Using 100 µL of serum or plasma, we quantified (signal-to-noise (S/N) ratio ≥10) 4–7 steroids depending on the species and sample, without derivatization. Steroids were extracted from serum or plasma using automated solid-phase extraction where samples were loaded onto C18 columns, washed with water and hexane, and then eluted with ethyl acetate. Quantitation by LC-MS/MS was done in positive ion, multiple reaction-monitoring (MRM) mode with an atmospheric pressure chemical ionization (APCI) source and heated nebulizer (500°C). Deuterated steroids served as internal standards and run time was 15 minutes. Extraction recoveries were 87–101% for the 8 analytes, and all intra- and inter-run CVs were ≤8.25%. This quantitation method yields good recoveries with variable lipid-content samples, avoids antibody cross-reactivity issues, and delivers results for multiple steroids. Thus, this method can enrich datasets by providing simultaneous quantitation of multiple steroids, and allow researchers to reimagine the hypotheses that could be tested with their volume-limited, lipemic, wildlife samples. Public Library of Science 2012-02-27 /pmc/articles/PMC3288106/ /pubmed/22384262 http://dx.doi.org/10.1371/journal.pone.0032496 Text en Koren et al. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Koren, Lee Ng, Ella S. M. Soma, Kiran K. Wynne-Edwards, Katherine E. Sample Preparation and Liquid Chromatography-Tandem Mass Spectrometry for Multiple Steroids in Mammalian and Avian Circulation |
title | Sample Preparation and Liquid Chromatography-Tandem Mass Spectrometry for Multiple Steroids in Mammalian and Avian Circulation |
title_full | Sample Preparation and Liquid Chromatography-Tandem Mass Spectrometry for Multiple Steroids in Mammalian and Avian Circulation |
title_fullStr | Sample Preparation and Liquid Chromatography-Tandem Mass Spectrometry for Multiple Steroids in Mammalian and Avian Circulation |
title_full_unstemmed | Sample Preparation and Liquid Chromatography-Tandem Mass Spectrometry for Multiple Steroids in Mammalian and Avian Circulation |
title_short | Sample Preparation and Liquid Chromatography-Tandem Mass Spectrometry for Multiple Steroids in Mammalian and Avian Circulation |
title_sort | sample preparation and liquid chromatography-tandem mass spectrometry for multiple steroids in mammalian and avian circulation |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3288106/ https://www.ncbi.nlm.nih.gov/pubmed/22384262 http://dx.doi.org/10.1371/journal.pone.0032496 |
work_keys_str_mv | AT korenlee samplepreparationandliquidchromatographytandemmassspectrometryformultiplesteroidsinmammalianandaviancirculation AT ngellasm samplepreparationandliquidchromatographytandemmassspectrometryformultiplesteroidsinmammalianandaviancirculation AT somakirank samplepreparationandliquidchromatographytandemmassspectrometryformultiplesteroidsinmammalianandaviancirculation AT wynneedwardskatherinee samplepreparationandliquidchromatographytandemmassspectrometryformultiplesteroidsinmammalianandaviancirculation |