A Non-Intrusive GMA Welding Process Quality Monitoring System Using Acoustic Sensing
Most of the inspection methods used for detection and localization of welding disturbances are based on the evaluation of some direct measurements of welding parameters. This direct measurement requires an insertion of sensors during the welding process which could somehow alter the behavior of the...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3290464/ https://www.ncbi.nlm.nih.gov/pubmed/22399990 http://dx.doi.org/10.3390/s90907150 |
_version_ | 1782224996820582400 |
---|---|
author | Cayo, Eber Huanca Alfaro, Sadek Crisostomo Absi |
author_facet | Cayo, Eber Huanca Alfaro, Sadek Crisostomo Absi |
author_sort | Cayo, Eber Huanca |
collection | PubMed |
description | Most of the inspection methods used for detection and localization of welding disturbances are based on the evaluation of some direct measurements of welding parameters. This direct measurement requires an insertion of sensors during the welding process which could somehow alter the behavior of the metallic transference. An inspection method that evaluates the GMA welding process evolution using a non-intrusive process sensing would allow not only the identification of disturbances during welding runs and thus reduce inspection time, but would also reduce the interference on the process caused by the direct sensing. In this paper a nonintrusive method for weld disturbance detection and localization for weld quality evaluation is demonstrated. The system is based on the acoustic sensing of the welding electrical arc. During repetitive tests in welds without disturbances, the stability acoustic parameters were calculated and used as comparison references for the detection and location of disturbances during the weld runs. |
format | Online Article Text |
id | pubmed-3290464 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-32904642012-03-07 A Non-Intrusive GMA Welding Process Quality Monitoring System Using Acoustic Sensing Cayo, Eber Huanca Alfaro, Sadek Crisostomo Absi Sensors (Basel) Article Most of the inspection methods used for detection and localization of welding disturbances are based on the evaluation of some direct measurements of welding parameters. This direct measurement requires an insertion of sensors during the welding process which could somehow alter the behavior of the metallic transference. An inspection method that evaluates the GMA welding process evolution using a non-intrusive process sensing would allow not only the identification of disturbances during welding runs and thus reduce inspection time, but would also reduce the interference on the process caused by the direct sensing. In this paper a nonintrusive method for weld disturbance detection and localization for weld quality evaluation is demonstrated. The system is based on the acoustic sensing of the welding electrical arc. During repetitive tests in welds without disturbances, the stability acoustic parameters were calculated and used as comparison references for the detection and location of disturbances during the weld runs. Molecular Diversity Preservation International (MDPI) 2009-09-09 /pmc/articles/PMC3290464/ /pubmed/22399990 http://dx.doi.org/10.3390/s90907150 Text en © 2009 by the authors; licensee MDPI, Basel, Switzerland This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Cayo, Eber Huanca Alfaro, Sadek Crisostomo Absi A Non-Intrusive GMA Welding Process Quality Monitoring System Using Acoustic Sensing |
title | A Non-Intrusive GMA Welding Process Quality Monitoring System Using Acoustic Sensing |
title_full | A Non-Intrusive GMA Welding Process Quality Monitoring System Using Acoustic Sensing |
title_fullStr | A Non-Intrusive GMA Welding Process Quality Monitoring System Using Acoustic Sensing |
title_full_unstemmed | A Non-Intrusive GMA Welding Process Quality Monitoring System Using Acoustic Sensing |
title_short | A Non-Intrusive GMA Welding Process Quality Monitoring System Using Acoustic Sensing |
title_sort | non-intrusive gma welding process quality monitoring system using acoustic sensing |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3290464/ https://www.ncbi.nlm.nih.gov/pubmed/22399990 http://dx.doi.org/10.3390/s90907150 |
work_keys_str_mv | AT cayoeberhuanca anonintrusivegmaweldingprocessqualitymonitoringsystemusingacousticsensing AT alfarosadekcrisostomoabsi anonintrusivegmaweldingprocessqualitymonitoringsystemusingacousticsensing AT cayoeberhuanca nonintrusivegmaweldingprocessqualitymonitoringsystemusingacousticsensing AT alfarosadekcrisostomoabsi nonintrusivegmaweldingprocessqualitymonitoringsystemusingacousticsensing |