Cargando…
A Portable Luminometer with a Disposable Electrochemiluminescent Biosensor for Lactate Determination
A hand-held luminometer for measuring electrochemiluminescence (ECL) for lactate determination and based on one-shot biosensors fabricated using screen-printed electrodes is described. The lactate recognition system is based on lactate oxidase and the transduction system consists of electro-oxidatio...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3292078/ https://www.ncbi.nlm.nih.gov/pubmed/22408475 http://dx.doi.org/10.3390/s91007694 |
_version_ | 1782225227764203520 |
---|---|
author | Martínez-Olmos, Antonio Ballesta-Claver, Julio Palma, Alberto J. Valencia-Mirón, Maria del Carmen Capitán-Vallvey, Luis Fermin |
author_facet | Martínez-Olmos, Antonio Ballesta-Claver, Julio Palma, Alberto J. Valencia-Mirón, Maria del Carmen Capitán-Vallvey, Luis Fermin |
author_sort | Martínez-Olmos, Antonio |
collection | PubMed |
description | A hand-held luminometer for measuring electrochemiluminescence (ECL) for lactate determination and based on one-shot biosensors fabricated using screen-printed electrodes is described. The lactate recognition system is based on lactate oxidase and the transduction system consists of electro-oxidation of luminol, with all the reagents immobilized in a Methocel membrane. The membrane composition and reaction conditions have been optimized to obtain adequate sensitivity. The luminometer is based on a large silicon photodiode as detector and includes a programmable potentiostat to initialize the chemical reaction and signal processing circuitry, designed to acquire a low level photocurrent with offset cancelation, low pass filtering for noise attenuation and adjustable gain up to 10(12) V/A. The one-shot biosensor responds to lactate rapidly, with an acquisition time of 2.5 min, obtaining a linear dependence from 8 × 10(−6) to 2 × 10(−4) M, a detection limit of 2.4 × 10(−6) M and a sensor-to-sensor reproducibility (relative standard deviation, RSD) of around 7–10 % at the medium level of the range. |
format | Online Article Text |
id | pubmed-3292078 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-32920782012-03-09 A Portable Luminometer with a Disposable Electrochemiluminescent Biosensor for Lactate Determination Martínez-Olmos, Antonio Ballesta-Claver, Julio Palma, Alberto J. Valencia-Mirón, Maria del Carmen Capitán-Vallvey, Luis Fermin Sensors (Basel) Article A hand-held luminometer for measuring electrochemiluminescence (ECL) for lactate determination and based on one-shot biosensors fabricated using screen-printed electrodes is described. The lactate recognition system is based on lactate oxidase and the transduction system consists of electro-oxidation of luminol, with all the reagents immobilized in a Methocel membrane. The membrane composition and reaction conditions have been optimized to obtain adequate sensitivity. The luminometer is based on a large silicon photodiode as detector and includes a programmable potentiostat to initialize the chemical reaction and signal processing circuitry, designed to acquire a low level photocurrent with offset cancelation, low pass filtering for noise attenuation and adjustable gain up to 10(12) V/A. The one-shot biosensor responds to lactate rapidly, with an acquisition time of 2.5 min, obtaining a linear dependence from 8 × 10(−6) to 2 × 10(−4) M, a detection limit of 2.4 × 10(−6) M and a sensor-to-sensor reproducibility (relative standard deviation, RSD) of around 7–10 % at the medium level of the range. Molecular Diversity Preservation International (MDPI) 2009-09-28 /pmc/articles/PMC3292078/ /pubmed/22408475 http://dx.doi.org/10.3390/s91007694 Text en © 2009 by the authors; licensee Molecular Diversity Preservation International, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Martínez-Olmos, Antonio Ballesta-Claver, Julio Palma, Alberto J. Valencia-Mirón, Maria del Carmen Capitán-Vallvey, Luis Fermin A Portable Luminometer with a Disposable Electrochemiluminescent Biosensor for Lactate Determination |
title | A Portable Luminometer with a Disposable Electrochemiluminescent Biosensor for Lactate Determination |
title_full | A Portable Luminometer with a Disposable Electrochemiluminescent Biosensor for Lactate Determination |
title_fullStr | A Portable Luminometer with a Disposable Electrochemiluminescent Biosensor for Lactate Determination |
title_full_unstemmed | A Portable Luminometer with a Disposable Electrochemiluminescent Biosensor for Lactate Determination |
title_short | A Portable Luminometer with a Disposable Electrochemiluminescent Biosensor for Lactate Determination |
title_sort | portable luminometer with a disposable electrochemiluminescent biosensor for lactate determination |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3292078/ https://www.ncbi.nlm.nih.gov/pubmed/22408475 http://dx.doi.org/10.3390/s91007694 |
work_keys_str_mv | AT martinezolmosantonio aportableluminometerwithadisposableelectrochemiluminescentbiosensorforlactatedetermination AT ballestaclaverjulio aportableluminometerwithadisposableelectrochemiluminescentbiosensorforlactatedetermination AT palmaalbertoj aportableluminometerwithadisposableelectrochemiluminescentbiosensorforlactatedetermination AT valenciamironmariadelcarmen aportableluminometerwithadisposableelectrochemiluminescentbiosensorforlactatedetermination AT capitanvallveyluisfermin aportableluminometerwithadisposableelectrochemiluminescentbiosensorforlactatedetermination AT martinezolmosantonio portableluminometerwithadisposableelectrochemiluminescentbiosensorforlactatedetermination AT ballestaclaverjulio portableluminometerwithadisposableelectrochemiluminescentbiosensorforlactatedetermination AT palmaalbertoj portableluminometerwithadisposableelectrochemiluminescentbiosensorforlactatedetermination AT valenciamironmariadelcarmen portableluminometerwithadisposableelectrochemiluminescentbiosensorforlactatedetermination AT capitanvallveyluisfermin portableluminometerwithadisposableelectrochemiluminescentbiosensorforlactatedetermination |