Compensation method for obtaining accurate, sub-micrometer displacement measurements of immersed specimens using electronic speckle interferometry
We proposed and validated a compensation method that accounts for the optical distortion inherent in measuring displacements on specimens immersed in aqueous solution. A spherically-shaped rubber specimen was mounted and pressurized on a custom apparatus, with the resulting surface displacements rec...
Autores principales: | Fazio, Massimo A., Bruno, Luigi, Reynaud, Juan F., Poggialini, Andrea, Downs, J. Crawford |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Optical Society of America
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3296530/ https://www.ncbi.nlm.nih.gov/pubmed/22435090 http://dx.doi.org/10.1364/BOE.3.000407 |