Cargando…

FDK-Type Algorithms with No Backprojection Weight for Circular and Helical Scan CT

We develop two Feldkamp-type reconstruction algorithms with no backprojection weight for circular and helical trajectory with planar detector geometry. Advances in solid-state electronic detector technologies lend importance to CT systems with the equispaced linear array, the planar (flat panel) det...

Descripción completa

Detalles Bibliográficos
Autores principales: Narasimhadhan, A. V., Rajgopal, Kasi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3296957/
https://www.ncbi.nlm.nih.gov/pubmed/22481912
http://dx.doi.org/10.1155/2012/969432
_version_ 1782225810841665536
author Narasimhadhan, A. V.
Rajgopal, Kasi
author_facet Narasimhadhan, A. V.
Rajgopal, Kasi
author_sort Narasimhadhan, A. V.
collection PubMed
description We develop two Feldkamp-type reconstruction algorithms with no backprojection weight for circular and helical trajectory with planar detector geometry. Advances in solid-state electronic detector technologies lend importance to CT systems with the equispaced linear array, the planar (flat panel) detectors, and the corresponding algorithms. We derive two exact Hilbert filtered backprojection (FBP) reconstruction algorithms with no backprojection weight for 2D fan-beam equispace linear array detector geometry (complement of the equi-angular curved array detector). Based on these algorithms, the Feldkamp-type algorithms with no backprojection weight for 3D reconstruction are developed using the standard heuristic extension of the divergent beam FBP algorithm. The simulation results show that the axial intensity drop in the reconstructed image using the FDK algorithms with no backprojection weight with circular trajectory is similar to that obtained by using Hu's and T-FDK, algorithms. Further, we present efficient algorithms to reduce the axial intensity drop encountered in the standard FDK reconstructions in circular cone-beam CT. The proposed algorithms consist of mainly two steps: reconstruction of the object using FDK algorithm with no backprojection weight and estimation of the missing term. The efficient algorithms are compared with the FDK algorithm, Hu's algorithm, T-FDK, and Zhu et al.'s algorithm in terms of axial intensity drop and noise. Simulation shows that the efficient algorithms give similar performance in axial intensity drop as that of Zhu et al.'s algorithm while one of the efficient algorithms outperforms Zhu et al.'s algorithm in terms of computational complexity.
format Online
Article
Text
id pubmed-3296957
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-32969572012-04-05 FDK-Type Algorithms with No Backprojection Weight for Circular and Helical Scan CT Narasimhadhan, A. V. Rajgopal, Kasi Int J Biomed Imaging Research Article We develop two Feldkamp-type reconstruction algorithms with no backprojection weight for circular and helical trajectory with planar detector geometry. Advances in solid-state electronic detector technologies lend importance to CT systems with the equispaced linear array, the planar (flat panel) detectors, and the corresponding algorithms. We derive two exact Hilbert filtered backprojection (FBP) reconstruction algorithms with no backprojection weight for 2D fan-beam equispace linear array detector geometry (complement of the equi-angular curved array detector). Based on these algorithms, the Feldkamp-type algorithms with no backprojection weight for 3D reconstruction are developed using the standard heuristic extension of the divergent beam FBP algorithm. The simulation results show that the axial intensity drop in the reconstructed image using the FDK algorithms with no backprojection weight with circular trajectory is similar to that obtained by using Hu's and T-FDK, algorithms. Further, we present efficient algorithms to reduce the axial intensity drop encountered in the standard FDK reconstructions in circular cone-beam CT. The proposed algorithms consist of mainly two steps: reconstruction of the object using FDK algorithm with no backprojection weight and estimation of the missing term. The efficient algorithms are compared with the FDK algorithm, Hu's algorithm, T-FDK, and Zhu et al.'s algorithm in terms of axial intensity drop and noise. Simulation shows that the efficient algorithms give similar performance in axial intensity drop as that of Zhu et al.'s algorithm while one of the efficient algorithms outperforms Zhu et al.'s algorithm in terms of computational complexity. Hindawi Publishing Corporation 2012 2012-02-16 /pmc/articles/PMC3296957/ /pubmed/22481912 http://dx.doi.org/10.1155/2012/969432 Text en Copyright © 2012 A. V. Narasimhadhan and K. Rajgopal. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Narasimhadhan, A. V.
Rajgopal, Kasi
FDK-Type Algorithms with No Backprojection Weight for Circular and Helical Scan CT
title FDK-Type Algorithms with No Backprojection Weight for Circular and Helical Scan CT
title_full FDK-Type Algorithms with No Backprojection Weight for Circular and Helical Scan CT
title_fullStr FDK-Type Algorithms with No Backprojection Weight for Circular and Helical Scan CT
title_full_unstemmed FDK-Type Algorithms with No Backprojection Weight for Circular and Helical Scan CT
title_short FDK-Type Algorithms with No Backprojection Weight for Circular and Helical Scan CT
title_sort fdk-type algorithms with no backprojection weight for circular and helical scan ct
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3296957/
https://www.ncbi.nlm.nih.gov/pubmed/22481912
http://dx.doi.org/10.1155/2012/969432
work_keys_str_mv AT narasimhadhanav fdktypealgorithmswithnobackprojectionweightforcircularandhelicalscanct
AT rajgopalkasi fdktypealgorithmswithnobackprojectionweightforcircularandhelicalscanct