Cargando…
Iatrogenic Duodenal Perforation Treated with Endoscopic Placement of Metallic Clips: A Case Report
Perforation is one of the major complications encountered during endoscopic procedures. The standard of care for these complications is either surgical intervention or nonoperative medical approach with antibiotics and bowel rest with or without parenteral alimentation. Metallic clips, initially dev...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3297480/ https://www.ncbi.nlm.nih.gov/pubmed/22431936 http://dx.doi.org/10.1155/2012/609750 |
_version_ | 1782225872060678144 |
---|---|
author | Solomon, Missale Schlachterman, Alexander Morgenstern, Ricardo |
author_facet | Solomon, Missale Schlachterman, Alexander Morgenstern, Ricardo |
author_sort | Solomon, Missale |
collection | PubMed |
description | Perforation is one of the major complications encountered during endoscopic procedures. The standard of care for these complications is either surgical intervention or nonoperative medical approach with antibiotics and bowel rest with or without parenteral alimentation. Metallic clips, initially developed to secure hemostasis in bleeding, have been successfully used to close perforations in the gastrointestinal tract (GI) including the duodenum. This avoids perioperative morbidities associated with surgical intervention while limiting the leakage of intestinal contents and peritoneal contamination that is possible with medical management. We present a case of a patient with a lateral duodenal perforation during an endoscopic retrograde cholangiopancreatography (ERCP) which was successfully treated with immediate placement of metallic endoclips. |
format | Online Article Text |
id | pubmed-3297480 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-32974802012-03-19 Iatrogenic Duodenal Perforation Treated with Endoscopic Placement of Metallic Clips: A Case Report Solomon, Missale Schlachterman, Alexander Morgenstern, Ricardo Case Rep Med Case Report Perforation is one of the major complications encountered during endoscopic procedures. The standard of care for these complications is either surgical intervention or nonoperative medical approach with antibiotics and bowel rest with or without parenteral alimentation. Metallic clips, initially developed to secure hemostasis in bleeding, have been successfully used to close perforations in the gastrointestinal tract (GI) including the duodenum. This avoids perioperative morbidities associated with surgical intervention while limiting the leakage of intestinal contents and peritoneal contamination that is possible with medical management. We present a case of a patient with a lateral duodenal perforation during an endoscopic retrograde cholangiopancreatography (ERCP) which was successfully treated with immediate placement of metallic endoclips. Hindawi Publishing Corporation 2012 2012-02-12 /pmc/articles/PMC3297480/ /pubmed/22431936 http://dx.doi.org/10.1155/2012/609750 Text en Copyright © 2012 Missale Solomon et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Solomon, Missale Schlachterman, Alexander Morgenstern, Ricardo Iatrogenic Duodenal Perforation Treated with Endoscopic Placement of Metallic Clips: A Case Report |
title | Iatrogenic Duodenal Perforation Treated with Endoscopic Placement of Metallic Clips: A Case Report |
title_full | Iatrogenic Duodenal Perforation Treated with Endoscopic Placement of Metallic Clips: A Case Report |
title_fullStr | Iatrogenic Duodenal Perforation Treated with Endoscopic Placement of Metallic Clips: A Case Report |
title_full_unstemmed | Iatrogenic Duodenal Perforation Treated with Endoscopic Placement of Metallic Clips: A Case Report |
title_short | Iatrogenic Duodenal Perforation Treated with Endoscopic Placement of Metallic Clips: A Case Report |
title_sort | iatrogenic duodenal perforation treated with endoscopic placement of metallic clips: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3297480/ https://www.ncbi.nlm.nih.gov/pubmed/22431936 http://dx.doi.org/10.1155/2012/609750 |
work_keys_str_mv | AT solomonmissale iatrogenicduodenalperforationtreatedwithendoscopicplacementofmetallicclipsacasereport AT schlachtermanalexander iatrogenicduodenalperforationtreatedwithendoscopicplacementofmetallicclipsacasereport AT morgensternricardo iatrogenicduodenalperforationtreatedwithendoscopicplacementofmetallicclipsacasereport |