Cargando…

Porous Hydroxyapatite and Aluminium-Oxide Ceramic Orbital Implant Evaluation Using CBCT Scanning: A Method for In Vivo Porous Structure Evaluation and Monitoring

Objective. This study aimed to define CBCT as a technique for postimplantation in vivo examination of porous hydroxyapatite and aluminium-oxide orbital implant shape, volume and density changes. Methods and Materials. CBCT was used to evaluate 30 enucleated patients treated with spherical polyglacti...

Descripción completa

Detalles Bibliográficos
Autores principales: Lukáts, Olga, Bujtár, Péter, Sándor, George K., Barabás, József
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3299339/
https://www.ncbi.nlm.nih.gov/pubmed/22481940
http://dx.doi.org/10.1155/2012/764749
_version_ 1782226111706431488
author Lukáts, Olga
Bujtár, Péter
Sándor, George K.
Barabás, József
author_facet Lukáts, Olga
Bujtár, Péter
Sándor, George K.
Barabás, József
author_sort Lukáts, Olga
collection PubMed
description Objective. This study aimed to define CBCT as a technique for postimplantation in vivo examination of porous hydroxyapatite and aluminium-oxide orbital implant shape, volume and density changes. Methods and Materials. CBCT was used to evaluate 30 enucleated patients treated with spherical polyglactin 910 wrapped hydroxyapatite and aluminum-oxide orbital implants. The mean duration of patient followup was 3.2 years or 1338 days with a range of 0.2 to 7.2 years or 79 to 2636 days in a population with an average age of 40.8 years. Results. The resolution of currently clinically used CBCT equipment allowed detailed structural observation of the orbital hydroxyapatite implants with some modifications. Volume and shape estimations were possible while density evaluation was more complicated compared to medical source computed tomography. The mean densities of the orbital implants were followed and a consistent gradual decrease identified from the beginning of implantation which was better defined after the applied correction procedure. Conclusion. CBCT with lower dosages of radiation exposure can be used to follow changes in implanted high-density porous structures. The density evaluation is possible with calibration modifications. Changes in orbital implant densities identified in this study may correspond to healing and maturation of soft tissues surrounding and penetrating the implants.
format Online
Article
Text
id pubmed-3299339
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-32993392012-04-05 Porous Hydroxyapatite and Aluminium-Oxide Ceramic Orbital Implant Evaluation Using CBCT Scanning: A Method for In Vivo Porous Structure Evaluation and Monitoring Lukáts, Olga Bujtár, Péter Sándor, George K. Barabás, József Int J Biomater Research Article Objective. This study aimed to define CBCT as a technique for postimplantation in vivo examination of porous hydroxyapatite and aluminium-oxide orbital implant shape, volume and density changes. Methods and Materials. CBCT was used to evaluate 30 enucleated patients treated with spherical polyglactin 910 wrapped hydroxyapatite and aluminum-oxide orbital implants. The mean duration of patient followup was 3.2 years or 1338 days with a range of 0.2 to 7.2 years or 79 to 2636 days in a population with an average age of 40.8 years. Results. The resolution of currently clinically used CBCT equipment allowed detailed structural observation of the orbital hydroxyapatite implants with some modifications. Volume and shape estimations were possible while density evaluation was more complicated compared to medical source computed tomography. The mean densities of the orbital implants were followed and a consistent gradual decrease identified from the beginning of implantation which was better defined after the applied correction procedure. Conclusion. CBCT with lower dosages of radiation exposure can be used to follow changes in implanted high-density porous structures. The density evaluation is possible with calibration modifications. Changes in orbital implant densities identified in this study may correspond to healing and maturation of soft tissues surrounding and penetrating the implants. Hindawi Publishing Corporation 2012 2012-02-28 /pmc/articles/PMC3299339/ /pubmed/22481940 http://dx.doi.org/10.1155/2012/764749 Text en Copyright © 2012 Olga Lukáts et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Lukáts, Olga
Bujtár, Péter
Sándor, George K.
Barabás, József
Porous Hydroxyapatite and Aluminium-Oxide Ceramic Orbital Implant Evaluation Using CBCT Scanning: A Method for In Vivo Porous Structure Evaluation and Monitoring
title Porous Hydroxyapatite and Aluminium-Oxide Ceramic Orbital Implant Evaluation Using CBCT Scanning: A Method for In Vivo Porous Structure Evaluation and Monitoring
title_full Porous Hydroxyapatite and Aluminium-Oxide Ceramic Orbital Implant Evaluation Using CBCT Scanning: A Method for In Vivo Porous Structure Evaluation and Monitoring
title_fullStr Porous Hydroxyapatite and Aluminium-Oxide Ceramic Orbital Implant Evaluation Using CBCT Scanning: A Method for In Vivo Porous Structure Evaluation and Monitoring
title_full_unstemmed Porous Hydroxyapatite and Aluminium-Oxide Ceramic Orbital Implant Evaluation Using CBCT Scanning: A Method for In Vivo Porous Structure Evaluation and Monitoring
title_short Porous Hydroxyapatite and Aluminium-Oxide Ceramic Orbital Implant Evaluation Using CBCT Scanning: A Method for In Vivo Porous Structure Evaluation and Monitoring
title_sort porous hydroxyapatite and aluminium-oxide ceramic orbital implant evaluation using cbct scanning: a method for in vivo porous structure evaluation and monitoring
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3299339/
https://www.ncbi.nlm.nih.gov/pubmed/22481940
http://dx.doi.org/10.1155/2012/764749
work_keys_str_mv AT lukatsolga poroushydroxyapatiteandaluminiumoxideceramicorbitalimplantevaluationusingcbctscanningamethodforinvivoporousstructureevaluationandmonitoring
AT bujtarpeter poroushydroxyapatiteandaluminiumoxideceramicorbitalimplantevaluationusingcbctscanningamethodforinvivoporousstructureevaluationandmonitoring
AT sandorgeorgek poroushydroxyapatiteandaluminiumoxideceramicorbitalimplantevaluationusingcbctscanningamethodforinvivoporousstructureevaluationandmonitoring
AT barabasjozsef poroushydroxyapatiteandaluminiumoxideceramicorbitalimplantevaluationusingcbctscanningamethodforinvivoporousstructureevaluationandmonitoring