Cargando…

Hemiarthroplasty versus angle-stable locking compression plate osteosynthesis in the treatment of three- and four-part fractures of the proximal humerus in the elderly: design of a randomized controlled trial

BACKGROUND: The optimal surgical management of dislocated three- and four-part fractures of the proximal humerus in elderly patients remains unclear. Most used techniques are hemiarthroplasty and angle-stable locking compression plate osteosynthesis. In the current literature there is no evidence av...

Descripción completa

Detalles Bibliográficos
Autores principales: Verbeek, Paul A, van den Akker-Scheek, Inge, Wendt, Klaus W, Diercks, Ron L
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3299658/
https://www.ncbi.nlm.nih.gov/pubmed/22321162
http://dx.doi.org/10.1186/1471-2474-13-16
_version_ 1782226142607966208
author Verbeek, Paul A
van den Akker-Scheek, Inge
Wendt, Klaus W
Diercks, Ron L
author_facet Verbeek, Paul A
van den Akker-Scheek, Inge
Wendt, Klaus W
Diercks, Ron L
author_sort Verbeek, Paul A
collection PubMed
description BACKGROUND: The optimal surgical management of dislocated three- and four-part fractures of the proximal humerus in elderly patients remains unclear. Most used techniques are hemiarthroplasty and angle-stable locking compression plate osteosynthesis. In the current literature there is no evidence available presenting superior results between hemiarthroplasty and angle-stable locking compression plate osteosynthesis in terms of speed of recovery, pain, patient satisfaction, functional outcome, quality of life or complications. METHODS/DESIGN: A randomized controlled multicenter trial will be conducted. Patients older than 60 years of age with a dislocated three- or four-part fracture of the proximal humerus as diagnosed by X-rays and CT-scans will be included. Exclusion criteria are a fracture older than 14 days, multiple comorbidity, multitrauma, a pathological fracture, previous surgery on the injured shoulder, severely deranged function caused by a previous disease, "head-split" proximal humerus fracture and unwillingness or inability to follow instructions. Participants will be randomized between surgical treatment with hemiarthroplasty and angle-stable locking compression plate osteosynthesis. Measurements will take place preoperatively and 3 months, 6 months, 9 months, 12 months and 24 months postoperatively. Primary outcome measure is speed of recovery of functional capacity of the affected upper limb using the Disabilities of Arm, Shoulder and Hand score (DASH). Secondary outcome measures are pain, patient satisfaction, shoulder function, quality of life, radiological evaluation and complications. Data will be analyzed on an intention-to-treat basis, using univariate and multivariate analyses. DISCUSSION: Both hemiarthroplasty and angle-stable locking compression plate osteosynthesis are used in the current treatment of dislocated three-and four-part fractures of the proximal humerus. There is a lack of level-1 studies comparing these two most-used surgical treatment options. This randomized controlled multicenter trial has been designed to determine which surgical treatment option provides the fastest recovery of functional capacity of the affected upper limb, and will provide better outcomes in pain, satisfaction, shoulder function, quality of life, radiological evaluation and complications. TRIAL REGISTRATION NUMBER: The trial is registered in the Netherlands Trial Registry (NTR2461)
format Online
Article
Text
id pubmed-3299658
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-32996582012-03-13 Hemiarthroplasty versus angle-stable locking compression plate osteosynthesis in the treatment of three- and four-part fractures of the proximal humerus in the elderly: design of a randomized controlled trial Verbeek, Paul A van den Akker-Scheek, Inge Wendt, Klaus W Diercks, Ron L BMC Musculoskelet Disord Study Protocol BACKGROUND: The optimal surgical management of dislocated three- and four-part fractures of the proximal humerus in elderly patients remains unclear. Most used techniques are hemiarthroplasty and angle-stable locking compression plate osteosynthesis. In the current literature there is no evidence available presenting superior results between hemiarthroplasty and angle-stable locking compression plate osteosynthesis in terms of speed of recovery, pain, patient satisfaction, functional outcome, quality of life or complications. METHODS/DESIGN: A randomized controlled multicenter trial will be conducted. Patients older than 60 years of age with a dislocated three- or four-part fracture of the proximal humerus as diagnosed by X-rays and CT-scans will be included. Exclusion criteria are a fracture older than 14 days, multiple comorbidity, multitrauma, a pathological fracture, previous surgery on the injured shoulder, severely deranged function caused by a previous disease, "head-split" proximal humerus fracture and unwillingness or inability to follow instructions. Participants will be randomized between surgical treatment with hemiarthroplasty and angle-stable locking compression plate osteosynthesis. Measurements will take place preoperatively and 3 months, 6 months, 9 months, 12 months and 24 months postoperatively. Primary outcome measure is speed of recovery of functional capacity of the affected upper limb using the Disabilities of Arm, Shoulder and Hand score (DASH). Secondary outcome measures are pain, patient satisfaction, shoulder function, quality of life, radiological evaluation and complications. Data will be analyzed on an intention-to-treat basis, using univariate and multivariate analyses. DISCUSSION: Both hemiarthroplasty and angle-stable locking compression plate osteosynthesis are used in the current treatment of dislocated three-and four-part fractures of the proximal humerus. There is a lack of level-1 studies comparing these two most-used surgical treatment options. This randomized controlled multicenter trial has been designed to determine which surgical treatment option provides the fastest recovery of functional capacity of the affected upper limb, and will provide better outcomes in pain, satisfaction, shoulder function, quality of life, radiological evaluation and complications. TRIAL REGISTRATION NUMBER: The trial is registered in the Netherlands Trial Registry (NTR2461) BioMed Central 2012-02-09 /pmc/articles/PMC3299658/ /pubmed/22321162 http://dx.doi.org/10.1186/1471-2474-13-16 Text en Copyright ©2012 Verbeek et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Study Protocol
Verbeek, Paul A
van den Akker-Scheek, Inge
Wendt, Klaus W
Diercks, Ron L
Hemiarthroplasty versus angle-stable locking compression plate osteosynthesis in the treatment of three- and four-part fractures of the proximal humerus in the elderly: design of a randomized controlled trial
title Hemiarthroplasty versus angle-stable locking compression plate osteosynthesis in the treatment of three- and four-part fractures of the proximal humerus in the elderly: design of a randomized controlled trial
title_full Hemiarthroplasty versus angle-stable locking compression plate osteosynthesis in the treatment of three- and four-part fractures of the proximal humerus in the elderly: design of a randomized controlled trial
title_fullStr Hemiarthroplasty versus angle-stable locking compression plate osteosynthesis in the treatment of three- and four-part fractures of the proximal humerus in the elderly: design of a randomized controlled trial
title_full_unstemmed Hemiarthroplasty versus angle-stable locking compression plate osteosynthesis in the treatment of three- and four-part fractures of the proximal humerus in the elderly: design of a randomized controlled trial
title_short Hemiarthroplasty versus angle-stable locking compression plate osteosynthesis in the treatment of three- and four-part fractures of the proximal humerus in the elderly: design of a randomized controlled trial
title_sort hemiarthroplasty versus angle-stable locking compression plate osteosynthesis in the treatment of three- and four-part fractures of the proximal humerus in the elderly: design of a randomized controlled trial
topic Study Protocol
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3299658/
https://www.ncbi.nlm.nih.gov/pubmed/22321162
http://dx.doi.org/10.1186/1471-2474-13-16
work_keys_str_mv AT verbeekpaula hemiarthroplastyversusanglestablelockingcompressionplateosteosynthesisinthetreatmentofthreeandfourpartfracturesoftheproximalhumerusintheelderlydesignofarandomizedcontrolledtrial
AT vandenakkerscheekinge hemiarthroplastyversusanglestablelockingcompressionplateosteosynthesisinthetreatmentofthreeandfourpartfracturesoftheproximalhumerusintheelderlydesignofarandomizedcontrolledtrial
AT wendtklausw hemiarthroplastyversusanglestablelockingcompressionplateosteosynthesisinthetreatmentofthreeandfourpartfracturesoftheproximalhumerusintheelderlydesignofarandomizedcontrolledtrial
AT diercksronl hemiarthroplastyversusanglestablelockingcompressionplateosteosynthesisinthetreatmentofthreeandfourpartfracturesoftheproximalhumerusintheelderlydesignofarandomizedcontrolledtrial