Cargando…
Sequential Determination of Total Arsenic and Cadmium in Concentrated Cadmium Sulphate Solutions by Flow-Through Stripping Chronopotentiometry after Online Cation Exchanger Separation
Flow-through stripping chronopotentiometry with a gold wire electrode was used for the determination of total arsenic and cadmium in cadmium sulphate solutions for cadmium production. The analysis is based on the online separation of arsenic as arsenate anion from cadmium cations by means of a catio...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3303185/ https://www.ncbi.nlm.nih.gov/pubmed/22448343 http://dx.doi.org/10.1155/2012/814983 |
_version_ | 1782226730789896192 |
---|---|
author | Cacho, Frantisek Lauko, Lukas Manova, Alena Dzurov, Jan Beinrohr, Ernest |
author_facet | Cacho, Frantisek Lauko, Lukas Manova, Alena Dzurov, Jan Beinrohr, Ernest |
author_sort | Cacho, Frantisek |
collection | PubMed |
description | Flow-through stripping chronopotentiometry with a gold wire electrode was used for the determination of total arsenic and cadmium in cadmium sulphate solutions for cadmium production. The analysis is based on the online separation of arsenic as arsenate anion from cadmium cations by means of a cation exchanger. On measuring arsenate in the effluent, the trapped cadmium is eluted by sodium chloride solution and determined in a small segment of the effluent by making use of the same electrode. The elaborated protocol enables a full automatic measurement of both species in the same sample solution. The accuracy of the results was confirmed by atomic absorption spectrometry. The LOD and LOQ for Arsenic were found to be 0.9 μg dm(−3) and 2.7 μg dm(−3), respectively. A linear response range was observed in the concentration range of 1 to 300 μg dm(−3) for sample volumes of 4 mL. The repeatability and reproducibility were found to be 2.9% and 5.2%, respectively. The linear response range for cadmium was found to be 0.5 to 60 g/L. The method was tested on samples from a cadmium production plant. |
format | Online Article Text |
id | pubmed-3303185 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-33031852012-03-23 Sequential Determination of Total Arsenic and Cadmium in Concentrated Cadmium Sulphate Solutions by Flow-Through Stripping Chronopotentiometry after Online Cation Exchanger Separation Cacho, Frantisek Lauko, Lukas Manova, Alena Dzurov, Jan Beinrohr, Ernest J Anal Methods Chem Research Article Flow-through stripping chronopotentiometry with a gold wire electrode was used for the determination of total arsenic and cadmium in cadmium sulphate solutions for cadmium production. The analysis is based on the online separation of arsenic as arsenate anion from cadmium cations by means of a cation exchanger. On measuring arsenate in the effluent, the trapped cadmium is eluted by sodium chloride solution and determined in a small segment of the effluent by making use of the same electrode. The elaborated protocol enables a full automatic measurement of both species in the same sample solution. The accuracy of the results was confirmed by atomic absorption spectrometry. The LOD and LOQ for Arsenic were found to be 0.9 μg dm(−3) and 2.7 μg dm(−3), respectively. A linear response range was observed in the concentration range of 1 to 300 μg dm(−3) for sample volumes of 4 mL. The repeatability and reproducibility were found to be 2.9% and 5.2%, respectively. The linear response range for cadmium was found to be 0.5 to 60 g/L. The method was tested on samples from a cadmium production plant. Hindawi Publishing Corporation 2012 2012-01-12 /pmc/articles/PMC3303185/ /pubmed/22448343 http://dx.doi.org/10.1155/2012/814983 Text en Copyright © 2012 Frantisek Cacho et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Cacho, Frantisek Lauko, Lukas Manova, Alena Dzurov, Jan Beinrohr, Ernest Sequential Determination of Total Arsenic and Cadmium in Concentrated Cadmium Sulphate Solutions by Flow-Through Stripping Chronopotentiometry after Online Cation Exchanger Separation |
title | Sequential Determination of Total Arsenic and Cadmium in Concentrated Cadmium Sulphate Solutions by Flow-Through Stripping Chronopotentiometry after Online Cation Exchanger Separation |
title_full | Sequential Determination of Total Arsenic and Cadmium in Concentrated Cadmium Sulphate Solutions by Flow-Through Stripping Chronopotentiometry after Online Cation Exchanger Separation |
title_fullStr | Sequential Determination of Total Arsenic and Cadmium in Concentrated Cadmium Sulphate Solutions by Flow-Through Stripping Chronopotentiometry after Online Cation Exchanger Separation |
title_full_unstemmed | Sequential Determination of Total Arsenic and Cadmium in Concentrated Cadmium Sulphate Solutions by Flow-Through Stripping Chronopotentiometry after Online Cation Exchanger Separation |
title_short | Sequential Determination of Total Arsenic and Cadmium in Concentrated Cadmium Sulphate Solutions by Flow-Through Stripping Chronopotentiometry after Online Cation Exchanger Separation |
title_sort | sequential determination of total arsenic and cadmium in concentrated cadmium sulphate solutions by flow-through stripping chronopotentiometry after online cation exchanger separation |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3303185/ https://www.ncbi.nlm.nih.gov/pubmed/22448343 http://dx.doi.org/10.1155/2012/814983 |
work_keys_str_mv | AT cachofrantisek sequentialdeterminationoftotalarsenicandcadmiuminconcentratedcadmiumsulphatesolutionsbyflowthroughstrippingchronopotentiometryafteronlinecationexchangerseparation AT laukolukas sequentialdeterminationoftotalarsenicandcadmiuminconcentratedcadmiumsulphatesolutionsbyflowthroughstrippingchronopotentiometryafteronlinecationexchangerseparation AT manovaalena sequentialdeterminationoftotalarsenicandcadmiuminconcentratedcadmiumsulphatesolutionsbyflowthroughstrippingchronopotentiometryafteronlinecationexchangerseparation AT dzurovjan sequentialdeterminationoftotalarsenicandcadmiuminconcentratedcadmiumsulphatesolutionsbyflowthroughstrippingchronopotentiometryafteronlinecationexchangerseparation AT beinrohrernest sequentialdeterminationoftotalarsenicandcadmiuminconcentratedcadmiumsulphatesolutionsbyflowthroughstrippingchronopotentiometryafteronlinecationexchangerseparation |