Cargando…

Miniaturized Protein Microarray with Internal Calibration as Point-of-Care Device for Diagnosis of Neonatal Sepsis

Neonatal sepsis is still a leading cause of death among newborns. Therefore a protein-microarray for point-of-care testing that simultaneously quantifies the sepsis associated serum proteins IL-6, IL-8, IL-10, TNF alpha, S-100, PCT, E-Selectin, CRP and Neopterin has been developed. The chip works wi...

Descripción completa

Detalles Bibliográficos
Autores principales: Buchegger, Patricia, Sauer, Ursula, Toth-Székély, Hedvig, Preininger, Claudia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3304124/
https://www.ncbi.nlm.nih.gov/pubmed/22438722
http://dx.doi.org/10.3390/s120201494
_version_ 1782226836843921408
author Buchegger, Patricia
Sauer, Ursula
Toth-Székély, Hedvig
Preininger, Claudia
author_facet Buchegger, Patricia
Sauer, Ursula
Toth-Székély, Hedvig
Preininger, Claudia
author_sort Buchegger, Patricia
collection PubMed
description Neonatal sepsis is still a leading cause of death among newborns. Therefore a protein-microarray for point-of-care testing that simultaneously quantifies the sepsis associated serum proteins IL-6, IL-8, IL-10, TNF alpha, S-100, PCT, E-Selectin, CRP and Neopterin has been developed. The chip works with only a 4 μL patient serum sample and hence minimizes excessive blood withdrawal from newborns. The 4 μL patient samples are diluted with 36 μL assay buffer and distributed to four slides for repetitive measurements. Streptavidin coated magnetic particles that act as distinct stirring detection components are added, not only to stir the sample, but also to detect antibody antigen binding events. We demonstrate that the test is complete within 2.5 h using a single step assay. S-100 conjugated to BSA is spotted in increasing concentrations to create an internal calibration. The presented low volume protein-chip fulfills the requirements of point-of-care testing for accurate and repeatable (CV < 14%) quantification of serum proteins for the diagnosis of neonatal sepsis.
format Online
Article
Text
id pubmed-3304124
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-33041242012-03-21 Miniaturized Protein Microarray with Internal Calibration as Point-of-Care Device for Diagnosis of Neonatal Sepsis Buchegger, Patricia Sauer, Ursula Toth-Székély, Hedvig Preininger, Claudia Sensors (Basel) Article Neonatal sepsis is still a leading cause of death among newborns. Therefore a protein-microarray for point-of-care testing that simultaneously quantifies the sepsis associated serum proteins IL-6, IL-8, IL-10, TNF alpha, S-100, PCT, E-Selectin, CRP and Neopterin has been developed. The chip works with only a 4 μL patient serum sample and hence minimizes excessive blood withdrawal from newborns. The 4 μL patient samples are diluted with 36 μL assay buffer and distributed to four slides for repetitive measurements. Streptavidin coated magnetic particles that act as distinct stirring detection components are added, not only to stir the sample, but also to detect antibody antigen binding events. We demonstrate that the test is complete within 2.5 h using a single step assay. S-100 conjugated to BSA is spotted in increasing concentrations to create an internal calibration. The presented low volume protein-chip fulfills the requirements of point-of-care testing for accurate and repeatable (CV < 14%) quantification of serum proteins for the diagnosis of neonatal sepsis. Molecular Diversity Preservation International (MDPI) 2012-02-03 /pmc/articles/PMC3304124/ /pubmed/22438722 http://dx.doi.org/10.3390/s120201494 Text en © 2012 by the authors; licensee MDPI, Basel, Switzerland https://creativecommons.org/licenses/by/3.0/This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/ (https://creativecommons.org/licenses/by/3.0/) ).
spellingShingle Article
Buchegger, Patricia
Sauer, Ursula
Toth-Székély, Hedvig
Preininger, Claudia
Miniaturized Protein Microarray with Internal Calibration as Point-of-Care Device for Diagnosis of Neonatal Sepsis
title Miniaturized Protein Microarray with Internal Calibration as Point-of-Care Device for Diagnosis of Neonatal Sepsis
title_full Miniaturized Protein Microarray with Internal Calibration as Point-of-Care Device for Diagnosis of Neonatal Sepsis
title_fullStr Miniaturized Protein Microarray with Internal Calibration as Point-of-Care Device for Diagnosis of Neonatal Sepsis
title_full_unstemmed Miniaturized Protein Microarray with Internal Calibration as Point-of-Care Device for Diagnosis of Neonatal Sepsis
title_short Miniaturized Protein Microarray with Internal Calibration as Point-of-Care Device for Diagnosis of Neonatal Sepsis
title_sort miniaturized protein microarray with internal calibration as point-of-care device for diagnosis of neonatal sepsis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3304124/
https://www.ncbi.nlm.nih.gov/pubmed/22438722
http://dx.doi.org/10.3390/s120201494
work_keys_str_mv AT bucheggerpatricia miniaturizedproteinmicroarraywithinternalcalibrationaspointofcaredevicefordiagnosisofneonatalsepsis
AT sauerursula miniaturizedproteinmicroarraywithinternalcalibrationaspointofcaredevicefordiagnosisofneonatalsepsis
AT tothszekelyhedvig miniaturizedproteinmicroarraywithinternalcalibrationaspointofcaredevicefordiagnosisofneonatalsepsis
AT preiningerclaudia miniaturizedproteinmicroarraywithinternalcalibrationaspointofcaredevicefordiagnosisofneonatalsepsis