Cargando…

Evaluation of the plasma quality after filtration

BACKGROUND AND THE PURPOSE OF THE STUDY: The quality of some of the human plasma derived drugs such as coagulation factor VIII and coagulation factor IX which can be used for the treatment of hemophilia A and B, depends on their activity which may be affected by filtration. In this study the quality...

Descripción completa

Detalles Bibliográficos
Autores principales: Mahmoodian Shooshtari, M., Mousavi Hosseini, K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tehran University of Medical Sciences 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3304377/
https://www.ncbi.nlm.nih.gov/pubmed/22615604
_version_ 1782226890079076352
author Mahmoodian Shooshtari, M.
Mousavi Hosseini, K.
author_facet Mahmoodian Shooshtari, M.
Mousavi Hosseini, K.
author_sort Mahmoodian Shooshtari, M.
collection PubMed
description BACKGROUND AND THE PURPOSE OF THE STUDY: The quality of some of the human plasma derived drugs such as coagulation factor VIII and coagulation factor IX which can be used for the treatment of hemophilia A and B, depends on their activity which may be affected by filtration. In this study the quality of plasma with respect to coagulation factors FVII, FVIII, FIX, FV, FXI, Fibrinogen, antithrombin III, anti-plasmin and antitrypsin activities obtained after plasma filtration with CPD (citrate-phosphate-dextrose) using integral filter was evaluated. METHODS: Sixty units of plasma were individually separated from whole blood by centrifugation and immediately filtered by integral filter system. Specific plasma filtration was carried out between 4 and 20 hrs after blood donation. Before filtration, 60 units of non filtered fresh plasmas were kept as control. Coagulation factors were determined by one-stage clotting assay in an automated system. Antithrombin III activity was determined by immunochrom assay in an automated system. Activity of anti-plasmin was determined by Berichrom α(2)-antiplasmin and antitrypsin activity was assayed with human neutrophil elastase. RESULTS: The activity of coagulation factors FVIII, FIX, Fibrinogen, FV, and FXI, were not affected by filtration, in all experiments. Filtration only caused negligible change in FVII activity. Antithrombin III, anti-plasmin and antitrypsin activities were not influenced by filtration. Nonfiltrated and filtrated plasma values were not significantly different (P> 0.05). CONCLUSIONS: Plasma filtration dose not result in a measurable impairment of coagulation factors and inhibitors. Although a little changes in FVII activity was observed after filtration, but these filtration-dependent changes apparently have no impact on the therapeutic quality of whole blood- filtered fresh plasma for transfusion.
format Online
Article
Text
id pubmed-3304377
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Tehran University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-33043772012-05-21 Evaluation of the plasma quality after filtration Mahmoodian Shooshtari, M. Mousavi Hosseini, K. Daru Original Article BACKGROUND AND THE PURPOSE OF THE STUDY: The quality of some of the human plasma derived drugs such as coagulation factor VIII and coagulation factor IX which can be used for the treatment of hemophilia A and B, depends on their activity which may be affected by filtration. In this study the quality of plasma with respect to coagulation factors FVII, FVIII, FIX, FV, FXI, Fibrinogen, antithrombin III, anti-plasmin and antitrypsin activities obtained after plasma filtration with CPD (citrate-phosphate-dextrose) using integral filter was evaluated. METHODS: Sixty units of plasma were individually separated from whole blood by centrifugation and immediately filtered by integral filter system. Specific plasma filtration was carried out between 4 and 20 hrs after blood donation. Before filtration, 60 units of non filtered fresh plasmas were kept as control. Coagulation factors were determined by one-stage clotting assay in an automated system. Antithrombin III activity was determined by immunochrom assay in an automated system. Activity of anti-plasmin was determined by Berichrom α(2)-antiplasmin and antitrypsin activity was assayed with human neutrophil elastase. RESULTS: The activity of coagulation factors FVIII, FIX, Fibrinogen, FV, and FXI, were not affected by filtration, in all experiments. Filtration only caused negligible change in FVII activity. Antithrombin III, anti-plasmin and antitrypsin activities were not influenced by filtration. Nonfiltrated and filtrated plasma values were not significantly different (P> 0.05). CONCLUSIONS: Plasma filtration dose not result in a measurable impairment of coagulation factors and inhibitors. Although a little changes in FVII activity was observed after filtration, but these filtration-dependent changes apparently have no impact on the therapeutic quality of whole blood- filtered fresh plasma for transfusion. Tehran University of Medical Sciences 2010 /pmc/articles/PMC3304377/ /pubmed/22615604 Text en © 2010 Tehran University of Medical Sciences http://creativecommons.org/licenses/by/3.0/ This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly.
spellingShingle Original Article
Mahmoodian Shooshtari, M.
Mousavi Hosseini, K.
Evaluation of the plasma quality after filtration
title Evaluation of the plasma quality after filtration
title_full Evaluation of the plasma quality after filtration
title_fullStr Evaluation of the plasma quality after filtration
title_full_unstemmed Evaluation of the plasma quality after filtration
title_short Evaluation of the plasma quality after filtration
title_sort evaluation of the plasma quality after filtration
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3304377/
https://www.ncbi.nlm.nih.gov/pubmed/22615604
work_keys_str_mv AT mahmoodianshooshtarim evaluationoftheplasmaqualityafterfiltration
AT mousavihosseinik evaluationoftheplasmaqualityafterfiltration