Cargando…

Combining Nitrous Oxide with Carbon Dioxide Decreases the Time to Loss of Consciousness during Euthanasia in Mice — Refinement of Animal Welfare?

Carbon dioxide (CO(2)) is the most commonly used euthanasia agent for rodents despite potentially causing pain and distress. Nitrous oxide is used in man to speed induction of anaesthesia with volatile anaesthetics, via a mechanism referred to as the “second gas” effect. We therefore evaluated the a...

Descripción completa

Detalles Bibliográficos
Autores principales: Thomas, Aurelie A., Flecknell, Paul A., Golledge, Huw D. R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3305278/
https://www.ncbi.nlm.nih.gov/pubmed/22438874
http://dx.doi.org/10.1371/journal.pone.0032290
_version_ 1782227035441070080
author Thomas, Aurelie A.
Flecknell, Paul A.
Golledge, Huw D. R.
author_facet Thomas, Aurelie A.
Flecknell, Paul A.
Golledge, Huw D. R.
author_sort Thomas, Aurelie A.
collection PubMed
description Carbon dioxide (CO(2)) is the most commonly used euthanasia agent for rodents despite potentially causing pain and distress. Nitrous oxide is used in man to speed induction of anaesthesia with volatile anaesthetics, via a mechanism referred to as the “second gas” effect. We therefore evaluated the addition of Nitrous Oxide (N(2)O) to a rising CO(2) concentration could be used as a welfare refinement of the euthanasia process in mice, by shortening the duration of conscious exposure to CO2. Firstly, to assess the effect of N(2)O on the induction of anaesthesia in mice, 12 female C57Bl/6 mice were anaesthetized in a crossover protocol with the following combinations: Isoflurane (5%)+O(2) (95%); Isoflurane (5%)+N(2)O (75%)+O(2) (25%) and N(2)O (75%)+O(2) (25%) with a total flow rate of 3l/min (into a 7l induction chamber). The addition of N(2)O to isoflurane reduced the time to loss of the righting reflex by 17.6%. Secondly, 18 C57Bl/6 and 18 CD1 mice were individually euthanized by gradually filling the induction chamber with either: CO(2) (20% of the chamber volume.min−1); CO(2)+N(2)O (20 and 60% of the chamber volume.min(−1) respectively); or CO(2)+Nitrogen (N(2)) (20 and 60% of the chamber volume.min−1). Arterial partial pressure (P(a)) of O(2) and CO(2) were measured as well as blood pH and lactate. When compared to the gradually rising CO(2) euthanasia, addition of a high concentration of N(2)O to CO(2) lowered the time to loss of righting reflex by 10.3% (P<0.001), lead to a lower P(a)O(2) (12.55±3.67 mmHg, P<0.001), a higher lactataemia (4.64±1.04 mmol.l(−1), P = 0.026), without any behaviour indicative of distress. Nitrous oxide reduces the time of conscious exposure to gradually rising CO(2) during euthanasia and hence may reduce the duration of any stress or distress to which mice are exposed during euthanasia.
format Online
Article
Text
id pubmed-3305278
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-33052782012-03-21 Combining Nitrous Oxide with Carbon Dioxide Decreases the Time to Loss of Consciousness during Euthanasia in Mice — Refinement of Animal Welfare? Thomas, Aurelie A. Flecknell, Paul A. Golledge, Huw D. R. PLoS One Research Article Carbon dioxide (CO(2)) is the most commonly used euthanasia agent for rodents despite potentially causing pain and distress. Nitrous oxide is used in man to speed induction of anaesthesia with volatile anaesthetics, via a mechanism referred to as the “second gas” effect. We therefore evaluated the addition of Nitrous Oxide (N(2)O) to a rising CO(2) concentration could be used as a welfare refinement of the euthanasia process in mice, by shortening the duration of conscious exposure to CO2. Firstly, to assess the effect of N(2)O on the induction of anaesthesia in mice, 12 female C57Bl/6 mice were anaesthetized in a crossover protocol with the following combinations: Isoflurane (5%)+O(2) (95%); Isoflurane (5%)+N(2)O (75%)+O(2) (25%) and N(2)O (75%)+O(2) (25%) with a total flow rate of 3l/min (into a 7l induction chamber). The addition of N(2)O to isoflurane reduced the time to loss of the righting reflex by 17.6%. Secondly, 18 C57Bl/6 and 18 CD1 mice were individually euthanized by gradually filling the induction chamber with either: CO(2) (20% of the chamber volume.min−1); CO(2)+N(2)O (20 and 60% of the chamber volume.min(−1) respectively); or CO(2)+Nitrogen (N(2)) (20 and 60% of the chamber volume.min−1). Arterial partial pressure (P(a)) of O(2) and CO(2) were measured as well as blood pH and lactate. When compared to the gradually rising CO(2) euthanasia, addition of a high concentration of N(2)O to CO(2) lowered the time to loss of righting reflex by 10.3% (P<0.001), lead to a lower P(a)O(2) (12.55±3.67 mmHg, P<0.001), a higher lactataemia (4.64±1.04 mmol.l(−1), P = 0.026), without any behaviour indicative of distress. Nitrous oxide reduces the time of conscious exposure to gradually rising CO(2) during euthanasia and hence may reduce the duration of any stress or distress to which mice are exposed during euthanasia. Public Library of Science 2012-03-15 /pmc/articles/PMC3305278/ /pubmed/22438874 http://dx.doi.org/10.1371/journal.pone.0032290 Text en Thomas et al. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Thomas, Aurelie A.
Flecknell, Paul A.
Golledge, Huw D. R.
Combining Nitrous Oxide with Carbon Dioxide Decreases the Time to Loss of Consciousness during Euthanasia in Mice — Refinement of Animal Welfare?
title Combining Nitrous Oxide with Carbon Dioxide Decreases the Time to Loss of Consciousness during Euthanasia in Mice — Refinement of Animal Welfare?
title_full Combining Nitrous Oxide with Carbon Dioxide Decreases the Time to Loss of Consciousness during Euthanasia in Mice — Refinement of Animal Welfare?
title_fullStr Combining Nitrous Oxide with Carbon Dioxide Decreases the Time to Loss of Consciousness during Euthanasia in Mice — Refinement of Animal Welfare?
title_full_unstemmed Combining Nitrous Oxide with Carbon Dioxide Decreases the Time to Loss of Consciousness during Euthanasia in Mice — Refinement of Animal Welfare?
title_short Combining Nitrous Oxide with Carbon Dioxide Decreases the Time to Loss of Consciousness during Euthanasia in Mice — Refinement of Animal Welfare?
title_sort combining nitrous oxide with carbon dioxide decreases the time to loss of consciousness during euthanasia in mice — refinement of animal welfare?
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3305278/
https://www.ncbi.nlm.nih.gov/pubmed/22438874
http://dx.doi.org/10.1371/journal.pone.0032290
work_keys_str_mv AT thomasaureliea combiningnitrousoxidewithcarbondioxidedecreasesthetimetolossofconsciousnessduringeuthanasiainmicerefinementofanimalwelfare
AT flecknellpaula combiningnitrousoxidewithcarbondioxidedecreasesthetimetolossofconsciousnessduringeuthanasiainmicerefinementofanimalwelfare
AT golledgehuwdr combiningnitrousoxidewithcarbondioxidedecreasesthetimetolossofconsciousnessduringeuthanasiainmicerefinementofanimalwelfare