Cargando…
Ultrasonic scalpel causes greater depth of soft tissue necrosis compared to monopolar electrocautery at standard power level settings in a pig model
BACKGROUND: Ultrasonic scalpel (UC) and monopolar electrocautery (ME) are common tools for soft tissue dissection. However, morphological data on the related tissue alteration are discordant. We developed an automatic device for standardized sample excision and compared quality and depth of morpholo...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3305372/ https://www.ncbi.nlm.nih.gov/pubmed/22361346 http://dx.doi.org/10.1186/1471-2482-12-3 |
_version_ | 1782227055050489856 |
---|---|
author | Homayounfar, Kia Meis, Johanna Jung, Klaus Klosterhalfen, Bernd Sprenger, Thilo Conradi, Lena-Christin Langer, Claus Becker, Heinz |
author_facet | Homayounfar, Kia Meis, Johanna Jung, Klaus Klosterhalfen, Bernd Sprenger, Thilo Conradi, Lena-Christin Langer, Claus Becker, Heinz |
author_sort | Homayounfar, Kia |
collection | PubMed |
description | BACKGROUND: Ultrasonic scalpel (UC) and monopolar electrocautery (ME) are common tools for soft tissue dissection. However, morphological data on the related tissue alteration are discordant. We developed an automatic device for standardized sample excision and compared quality and depth of morphological changes caused by UC and ME in a pig model. METHODS: 100 tissue samples (5 × 3 cm) of the abdominal wall were excised in 16 pigs. Excisions were randomly performed manually or by using the self-constructed automatic device at standard power levels (60 W cutting in ME, level 5 in UC) for abdominal surgery. Quality of tissue alteration and depth of coagulation necrosis were examined histopathologically. Device (UC vs. ME) and mode (manually vs. automatic) effects were studied by two-way analysis of variance at a significance level of 5%. RESULTS: At the investigated power level settings UC and ME induced qualitatively similar coagulation necroses. Mean depth of necrosis was 450.4 ± 457.8 μm for manual UC and 553.5 ± 326.9 μm for automatic UC versus 149.0 ± 74.3 μm for manual ME and 257.6 ± 119.4 μm for automatic ME. Coagulation necrosis was significantly deeper (p < 0.01) when UC was used compared to ME. The mode of excision (manual versus automatic) did not influence the depth of necrosis (p = 0.85). There was no significant interaction between dissection tool and mode of excision (p = 0.93). CONCLUSIONS: Thermal injury caused by UC and ME results in qualitatively similar coagulation necrosis. The depth of necrosis is significantly greater in UC compared to ME at investigated standard power levels. |
format | Online Article Text |
id | pubmed-3305372 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-33053722012-03-16 Ultrasonic scalpel causes greater depth of soft tissue necrosis compared to monopolar electrocautery at standard power level settings in a pig model Homayounfar, Kia Meis, Johanna Jung, Klaus Klosterhalfen, Bernd Sprenger, Thilo Conradi, Lena-Christin Langer, Claus Becker, Heinz BMC Surg Research Article BACKGROUND: Ultrasonic scalpel (UC) and monopolar electrocautery (ME) are common tools for soft tissue dissection. However, morphological data on the related tissue alteration are discordant. We developed an automatic device for standardized sample excision and compared quality and depth of morphological changes caused by UC and ME in a pig model. METHODS: 100 tissue samples (5 × 3 cm) of the abdominal wall were excised in 16 pigs. Excisions were randomly performed manually or by using the self-constructed automatic device at standard power levels (60 W cutting in ME, level 5 in UC) for abdominal surgery. Quality of tissue alteration and depth of coagulation necrosis were examined histopathologically. Device (UC vs. ME) and mode (manually vs. automatic) effects were studied by two-way analysis of variance at a significance level of 5%. RESULTS: At the investigated power level settings UC and ME induced qualitatively similar coagulation necroses. Mean depth of necrosis was 450.4 ± 457.8 μm for manual UC and 553.5 ± 326.9 μm for automatic UC versus 149.0 ± 74.3 μm for manual ME and 257.6 ± 119.4 μm for automatic ME. Coagulation necrosis was significantly deeper (p < 0.01) when UC was used compared to ME. The mode of excision (manual versus automatic) did not influence the depth of necrosis (p = 0.85). There was no significant interaction between dissection tool and mode of excision (p = 0.93). CONCLUSIONS: Thermal injury caused by UC and ME results in qualitatively similar coagulation necrosis. The depth of necrosis is significantly greater in UC compared to ME at investigated standard power levels. BioMed Central 2012-02-23 /pmc/articles/PMC3305372/ /pubmed/22361346 http://dx.doi.org/10.1186/1471-2482-12-3 Text en Copyright ©2012 Homayounfar et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Homayounfar, Kia Meis, Johanna Jung, Klaus Klosterhalfen, Bernd Sprenger, Thilo Conradi, Lena-Christin Langer, Claus Becker, Heinz Ultrasonic scalpel causes greater depth of soft tissue necrosis compared to monopolar electrocautery at standard power level settings in a pig model |
title | Ultrasonic scalpel causes greater depth of soft tissue necrosis compared to monopolar electrocautery at standard power level settings in a pig model |
title_full | Ultrasonic scalpel causes greater depth of soft tissue necrosis compared to monopolar electrocautery at standard power level settings in a pig model |
title_fullStr | Ultrasonic scalpel causes greater depth of soft tissue necrosis compared to monopolar electrocautery at standard power level settings in a pig model |
title_full_unstemmed | Ultrasonic scalpel causes greater depth of soft tissue necrosis compared to monopolar electrocautery at standard power level settings in a pig model |
title_short | Ultrasonic scalpel causes greater depth of soft tissue necrosis compared to monopolar electrocautery at standard power level settings in a pig model |
title_sort | ultrasonic scalpel causes greater depth of soft tissue necrosis compared to monopolar electrocautery at standard power level settings in a pig model |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3305372/ https://www.ncbi.nlm.nih.gov/pubmed/22361346 http://dx.doi.org/10.1186/1471-2482-12-3 |
work_keys_str_mv | AT homayounfarkia ultrasonicscalpelcausesgreaterdepthofsofttissuenecrosiscomparedtomonopolarelectrocauteryatstandardpowerlevelsettingsinapigmodel AT meisjohanna ultrasonicscalpelcausesgreaterdepthofsofttissuenecrosiscomparedtomonopolarelectrocauteryatstandardpowerlevelsettingsinapigmodel AT jungklaus ultrasonicscalpelcausesgreaterdepthofsofttissuenecrosiscomparedtomonopolarelectrocauteryatstandardpowerlevelsettingsinapigmodel AT klosterhalfenbernd ultrasonicscalpelcausesgreaterdepthofsofttissuenecrosiscomparedtomonopolarelectrocauteryatstandardpowerlevelsettingsinapigmodel AT sprengerthilo ultrasonicscalpelcausesgreaterdepthofsofttissuenecrosiscomparedtomonopolarelectrocauteryatstandardpowerlevelsettingsinapigmodel AT conradilenachristin ultrasonicscalpelcausesgreaterdepthofsofttissuenecrosiscomparedtomonopolarelectrocauteryatstandardpowerlevelsettingsinapigmodel AT langerclaus ultrasonicscalpelcausesgreaterdepthofsofttissuenecrosiscomparedtomonopolarelectrocauteryatstandardpowerlevelsettingsinapigmodel AT beckerheinz ultrasonicscalpelcausesgreaterdepthofsofttissuenecrosiscomparedtomonopolarelectrocauteryatstandardpowerlevelsettingsinapigmodel |