Ultrasonic scalpel causes greater depth of soft tissue necrosis compared to monopolar electrocautery at standard power level settings in a pig model

BACKGROUND: Ultrasonic scalpel (UC) and monopolar electrocautery (ME) are common tools for soft tissue dissection. However, morphological data on the related tissue alteration are discordant. We developed an automatic device for standardized sample excision and compared quality and depth of morpholo...

Descripción completa

Detalles Bibliográficos
Autores principales: Homayounfar, Kia, Meis, Johanna, Jung, Klaus, Klosterhalfen, Bernd, Sprenger, Thilo, Conradi, Lena-Christin, Langer, Claus, Becker, Heinz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3305372/
https://www.ncbi.nlm.nih.gov/pubmed/22361346
http://dx.doi.org/10.1186/1471-2482-12-3
_version_ 1782227055050489856
author Homayounfar, Kia
Meis, Johanna
Jung, Klaus
Klosterhalfen, Bernd
Sprenger, Thilo
Conradi, Lena-Christin
Langer, Claus
Becker, Heinz
author_facet Homayounfar, Kia
Meis, Johanna
Jung, Klaus
Klosterhalfen, Bernd
Sprenger, Thilo
Conradi, Lena-Christin
Langer, Claus
Becker, Heinz
author_sort Homayounfar, Kia
collection PubMed
description BACKGROUND: Ultrasonic scalpel (UC) and monopolar electrocautery (ME) are common tools for soft tissue dissection. However, morphological data on the related tissue alteration are discordant. We developed an automatic device for standardized sample excision and compared quality and depth of morphological changes caused by UC and ME in a pig model. METHODS: 100 tissue samples (5 × 3 cm) of the abdominal wall were excised in 16 pigs. Excisions were randomly performed manually or by using the self-constructed automatic device at standard power levels (60 W cutting in ME, level 5 in UC) for abdominal surgery. Quality of tissue alteration and depth of coagulation necrosis were examined histopathologically. Device (UC vs. ME) and mode (manually vs. automatic) effects were studied by two-way analysis of variance at a significance level of 5%. RESULTS: At the investigated power level settings UC and ME induced qualitatively similar coagulation necroses. Mean depth of necrosis was 450.4 ± 457.8 μm for manual UC and 553.5 ± 326.9 μm for automatic UC versus 149.0 ± 74.3 μm for manual ME and 257.6 ± 119.4 μm for automatic ME. Coagulation necrosis was significantly deeper (p < 0.01) when UC was used compared to ME. The mode of excision (manual versus automatic) did not influence the depth of necrosis (p = 0.85). There was no significant interaction between dissection tool and mode of excision (p = 0.93). CONCLUSIONS: Thermal injury caused by UC and ME results in qualitatively similar coagulation necrosis. The depth of necrosis is significantly greater in UC compared to ME at investigated standard power levels.
format Online
Article
Text
id pubmed-3305372
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-33053722012-03-16 Ultrasonic scalpel causes greater depth of soft tissue necrosis compared to monopolar electrocautery at standard power level settings in a pig model Homayounfar, Kia Meis, Johanna Jung, Klaus Klosterhalfen, Bernd Sprenger, Thilo Conradi, Lena-Christin Langer, Claus Becker, Heinz BMC Surg Research Article BACKGROUND: Ultrasonic scalpel (UC) and monopolar electrocautery (ME) are common tools for soft tissue dissection. However, morphological data on the related tissue alteration are discordant. We developed an automatic device for standardized sample excision and compared quality and depth of morphological changes caused by UC and ME in a pig model. METHODS: 100 tissue samples (5 × 3 cm) of the abdominal wall were excised in 16 pigs. Excisions were randomly performed manually or by using the self-constructed automatic device at standard power levels (60 W cutting in ME, level 5 in UC) for abdominal surgery. Quality of tissue alteration and depth of coagulation necrosis were examined histopathologically. Device (UC vs. ME) and mode (manually vs. automatic) effects were studied by two-way analysis of variance at a significance level of 5%. RESULTS: At the investigated power level settings UC and ME induced qualitatively similar coagulation necroses. Mean depth of necrosis was 450.4 ± 457.8 μm for manual UC and 553.5 ± 326.9 μm for automatic UC versus 149.0 ± 74.3 μm for manual ME and 257.6 ± 119.4 μm for automatic ME. Coagulation necrosis was significantly deeper (p < 0.01) when UC was used compared to ME. The mode of excision (manual versus automatic) did not influence the depth of necrosis (p = 0.85). There was no significant interaction between dissection tool and mode of excision (p = 0.93). CONCLUSIONS: Thermal injury caused by UC and ME results in qualitatively similar coagulation necrosis. The depth of necrosis is significantly greater in UC compared to ME at investigated standard power levels. BioMed Central 2012-02-23 /pmc/articles/PMC3305372/ /pubmed/22361346 http://dx.doi.org/10.1186/1471-2482-12-3 Text en Copyright ©2012 Homayounfar et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Homayounfar, Kia
Meis, Johanna
Jung, Klaus
Klosterhalfen, Bernd
Sprenger, Thilo
Conradi, Lena-Christin
Langer, Claus
Becker, Heinz
Ultrasonic scalpel causes greater depth of soft tissue necrosis compared to monopolar electrocautery at standard power level settings in a pig model
title Ultrasonic scalpel causes greater depth of soft tissue necrosis compared to monopolar electrocautery at standard power level settings in a pig model
title_full Ultrasonic scalpel causes greater depth of soft tissue necrosis compared to monopolar electrocautery at standard power level settings in a pig model
title_fullStr Ultrasonic scalpel causes greater depth of soft tissue necrosis compared to monopolar electrocautery at standard power level settings in a pig model
title_full_unstemmed Ultrasonic scalpel causes greater depth of soft tissue necrosis compared to monopolar electrocautery at standard power level settings in a pig model
title_short Ultrasonic scalpel causes greater depth of soft tissue necrosis compared to monopolar electrocautery at standard power level settings in a pig model
title_sort ultrasonic scalpel causes greater depth of soft tissue necrosis compared to monopolar electrocautery at standard power level settings in a pig model
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3305372/
https://www.ncbi.nlm.nih.gov/pubmed/22361346
http://dx.doi.org/10.1186/1471-2482-12-3
work_keys_str_mv AT homayounfarkia ultrasonicscalpelcausesgreaterdepthofsofttissuenecrosiscomparedtomonopolarelectrocauteryatstandardpowerlevelsettingsinapigmodel
AT meisjohanna ultrasonicscalpelcausesgreaterdepthofsofttissuenecrosiscomparedtomonopolarelectrocauteryatstandardpowerlevelsettingsinapigmodel
AT jungklaus ultrasonicscalpelcausesgreaterdepthofsofttissuenecrosiscomparedtomonopolarelectrocauteryatstandardpowerlevelsettingsinapigmodel
AT klosterhalfenbernd ultrasonicscalpelcausesgreaterdepthofsofttissuenecrosiscomparedtomonopolarelectrocauteryatstandardpowerlevelsettingsinapigmodel
AT sprengerthilo ultrasonicscalpelcausesgreaterdepthofsofttissuenecrosiscomparedtomonopolarelectrocauteryatstandardpowerlevelsettingsinapigmodel
AT conradilenachristin ultrasonicscalpelcausesgreaterdepthofsofttissuenecrosiscomparedtomonopolarelectrocauteryatstandardpowerlevelsettingsinapigmodel
AT langerclaus ultrasonicscalpelcausesgreaterdepthofsofttissuenecrosiscomparedtomonopolarelectrocauteryatstandardpowerlevelsettingsinapigmodel
AT beckerheinz ultrasonicscalpelcausesgreaterdepthofsofttissuenecrosiscomparedtomonopolarelectrocauteryatstandardpowerlevelsettingsinapigmodel