Cargando…
The Availability of Radiological Measurement of Tibial Torsion: Three-Dimensional Computed Tomography Reconstruction
OBJECTIVE: To assess the intra-rater and inter-rater reliability for measuring tibial torsion measurements by a radiographic method using three-dimensional computed tomography reconstruction (3D-CT) and to compare the physical measures to those of 3D-CT. METHOD: The study included 33 children who pr...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Academy of Rehabilitation Medicine
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3309262/ https://www.ncbi.nlm.nih.gov/pubmed/22506190 http://dx.doi.org/10.5535/arm.2011.35.5.673 |
_version_ | 1782227501624328192 |
---|---|
author | Shin, Sang-yeop Yoon, Chul Ho Lee, Eun Shin Oh, Min-Kyun Kim, A Ram Park, Jong Moon Shin, Jun-Hwa Shin, Hee Suk |
author_facet | Shin, Sang-yeop Yoon, Chul Ho Lee, Eun Shin Oh, Min-Kyun Kim, A Ram Park, Jong Moon Shin, Jun-Hwa Shin, Hee Suk |
author_sort | Shin, Sang-yeop |
collection | PubMed |
description | OBJECTIVE: To assess the intra-rater and inter-rater reliability for measuring tibial torsion measurements by a radiographic method using three-dimensional computed tomography reconstruction (3D-CT) and to compare the physical measures to those of 3D-CT. METHOD: The study included 33 children who presented with intoeing gait. Tibial torsion was measured by 3D-CT. Distal reference point was the bimalleolar axis. Proximal reference points were the transtibial axis and posterior condylar axis. Physical measurements included thigh-foot angle (TFA) and bimalleolar angle (BMA). 3D-CT measurement and physical measurement were performed twice at both lower extremities by each rater. The intra-rater and inter-rater reliability were calculated by intraclass correlation coefficiency (ICC). The relationship between radiological and physical examination was calculated by Spearman correlation coefficient. RESULTS: The 3D-CT measures for tibial torsion were reliable within individual raters and between different raters. However, physical measures for tibial torsion were reliable within an individual rater but not reliable between raters. The 3D-CT measures by any proximal reference axis were more reliable within a rater and between raters than physical measurements. There was no significant impact introduced by the selection of the proximal reference axis. The correlation coefficiency between 3D-CT and physical measurement methods was low. CONCLUSION: Because the 3D-CT measurements for tibial torsion are more reliable than physical measurements, we recommend that accurate diagnosis of internal tibial torsion should be detected by using 3D-CT measurements. Also, considering the disadvantages of radiological measurements, physical measurement may be used for short term follow-up by same raters, as intra-rater reliability is relatively good. |
format | Online Article Text |
id | pubmed-3309262 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Korean Academy of Rehabilitation Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-33092622012-04-04 The Availability of Radiological Measurement of Tibial Torsion: Three-Dimensional Computed Tomography Reconstruction Shin, Sang-yeop Yoon, Chul Ho Lee, Eun Shin Oh, Min-Kyun Kim, A Ram Park, Jong Moon Shin, Jun-Hwa Shin, Hee Suk Ann Rehabil Med Original Article OBJECTIVE: To assess the intra-rater and inter-rater reliability for measuring tibial torsion measurements by a radiographic method using three-dimensional computed tomography reconstruction (3D-CT) and to compare the physical measures to those of 3D-CT. METHOD: The study included 33 children who presented with intoeing gait. Tibial torsion was measured by 3D-CT. Distal reference point was the bimalleolar axis. Proximal reference points were the transtibial axis and posterior condylar axis. Physical measurements included thigh-foot angle (TFA) and bimalleolar angle (BMA). 3D-CT measurement and physical measurement were performed twice at both lower extremities by each rater. The intra-rater and inter-rater reliability were calculated by intraclass correlation coefficiency (ICC). The relationship between radiological and physical examination was calculated by Spearman correlation coefficient. RESULTS: The 3D-CT measures for tibial torsion were reliable within individual raters and between different raters. However, physical measures for tibial torsion were reliable within an individual rater but not reliable between raters. The 3D-CT measures by any proximal reference axis were more reliable within a rater and between raters than physical measurements. There was no significant impact introduced by the selection of the proximal reference axis. The correlation coefficiency between 3D-CT and physical measurement methods was low. CONCLUSION: Because the 3D-CT measurements for tibial torsion are more reliable than physical measurements, we recommend that accurate diagnosis of internal tibial torsion should be detected by using 3D-CT measurements. Also, considering the disadvantages of radiological measurements, physical measurement may be used for short term follow-up by same raters, as intra-rater reliability is relatively good. Korean Academy of Rehabilitation Medicine 2011-10 2011-10-31 /pmc/articles/PMC3309262/ /pubmed/22506190 http://dx.doi.org/10.5535/arm.2011.35.5.673 Text en Copyright © 2011 by Korean Academy of Rehabilitation Medicine http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Shin, Sang-yeop Yoon, Chul Ho Lee, Eun Shin Oh, Min-Kyun Kim, A Ram Park, Jong Moon Shin, Jun-Hwa Shin, Hee Suk The Availability of Radiological Measurement of Tibial Torsion: Three-Dimensional Computed Tomography Reconstruction |
title | The Availability of Radiological Measurement of Tibial Torsion: Three-Dimensional Computed Tomography Reconstruction |
title_full | The Availability of Radiological Measurement of Tibial Torsion: Three-Dimensional Computed Tomography Reconstruction |
title_fullStr | The Availability of Radiological Measurement of Tibial Torsion: Three-Dimensional Computed Tomography Reconstruction |
title_full_unstemmed | The Availability of Radiological Measurement of Tibial Torsion: Three-Dimensional Computed Tomography Reconstruction |
title_short | The Availability of Radiological Measurement of Tibial Torsion: Three-Dimensional Computed Tomography Reconstruction |
title_sort | availability of radiological measurement of tibial torsion: three-dimensional computed tomography reconstruction |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3309262/ https://www.ncbi.nlm.nih.gov/pubmed/22506190 http://dx.doi.org/10.5535/arm.2011.35.5.673 |
work_keys_str_mv | AT shinsangyeop theavailabilityofradiologicalmeasurementoftibialtorsionthreedimensionalcomputedtomographyreconstruction AT yoonchulho theavailabilityofradiologicalmeasurementoftibialtorsionthreedimensionalcomputedtomographyreconstruction AT leeeunshin theavailabilityofradiologicalmeasurementoftibialtorsionthreedimensionalcomputedtomographyreconstruction AT ohminkyun theavailabilityofradiologicalmeasurementoftibialtorsionthreedimensionalcomputedtomographyreconstruction AT kimaram theavailabilityofradiologicalmeasurementoftibialtorsionthreedimensionalcomputedtomographyreconstruction AT parkjongmoon theavailabilityofradiologicalmeasurementoftibialtorsionthreedimensionalcomputedtomographyreconstruction AT shinjunhwa theavailabilityofradiologicalmeasurementoftibialtorsionthreedimensionalcomputedtomographyreconstruction AT shinheesuk theavailabilityofradiologicalmeasurementoftibialtorsionthreedimensionalcomputedtomographyreconstruction AT shinsangyeop availabilityofradiologicalmeasurementoftibialtorsionthreedimensionalcomputedtomographyreconstruction AT yoonchulho availabilityofradiologicalmeasurementoftibialtorsionthreedimensionalcomputedtomographyreconstruction AT leeeunshin availabilityofradiologicalmeasurementoftibialtorsionthreedimensionalcomputedtomographyreconstruction AT ohminkyun availabilityofradiologicalmeasurementoftibialtorsionthreedimensionalcomputedtomographyreconstruction AT kimaram availabilityofradiologicalmeasurementoftibialtorsionthreedimensionalcomputedtomographyreconstruction AT parkjongmoon availabilityofradiologicalmeasurementoftibialtorsionthreedimensionalcomputedtomographyreconstruction AT shinjunhwa availabilityofradiologicalmeasurementoftibialtorsionthreedimensionalcomputedtomographyreconstruction AT shinheesuk availabilityofradiologicalmeasurementoftibialtorsionthreedimensionalcomputedtomographyreconstruction |