dAcquisition setting optimization and quantitative imaging for (124)I studies with the Inveon microPET-CT system
BACKGROUND: Noninvasive multimodality imaging is essential for preclinical evaluation of the biodistribution and pharmacokinetics of radionuclide therapy and for monitoring tumor response. Imaging with nonstandard positron-emission tomography [PET] isotopes such as (124)I is promising in that contex...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3311594/ https://www.ncbi.nlm.nih.gov/pubmed/22330760 http://dx.doi.org/10.1186/2191-219X-2-7 |
_version_ | 1782227789225656320 |
---|---|
author | Anizan, Nadège Carlier, Thomas Hindorf, Cecilia Barbet, Jacques Bardiès, Manuel |
author_facet | Anizan, Nadège Carlier, Thomas Hindorf, Cecilia Barbet, Jacques Bardiès, Manuel |
author_sort | Anizan, Nadège |
collection | PubMed |
description | BACKGROUND: Noninvasive multimodality imaging is essential for preclinical evaluation of the biodistribution and pharmacokinetics of radionuclide therapy and for monitoring tumor response. Imaging with nonstandard positron-emission tomography [PET] isotopes such as (124)I is promising in that context but requires accurate activity quantification. The decay scheme of (124)I implies an optimization of both acquisition settings and correction processing. The PET scanner investigated in this study was the Inveon PET/CT system dedicated to small animal imaging. METHODS: The noise equivalent count rate [NECR], the scatter fraction [SF], and the gamma-prompt fraction [GF] were used to determine the best acquisition parameters for mouse- and rat-sized phantoms filled with (124)I. An image-quality phantom as specified by the National Electrical Manufacturers Association NU 4-2008 protocol was acquired and reconstructed with two-dimensional filtered back projection, 2D ordered-subset expectation maximization [2DOSEM], and 3DOSEM with maximum a posteriori [3DOSEM/MAP] algorithms, with and without attenuation correction, scatter correction, and gamma-prompt correction (weighted uniform distribution subtraction). RESULTS: Optimal energy windows were established for the rat phantom (390 to 550 keV) and the mouse phantom (400 to 590 keV) by combining the NECR, SF, and GF results. The coincidence time window had no significant impact regarding the NECR curve variation. Activity concentration of (124)I measured in the uniform region of an image-quality phantom was underestimated by 9.9% for the 3DOSEM/MAP algorithm with attenuation and scatter corrections, and by 23% with the gamma-prompt correction. Attenuation, scatter, and gamma-prompt corrections decreased the residual signal in the cold insert. CONCLUSIONS: The optimal energy windows were chosen with the NECR, SF, and GF evaluation. Nevertheless, an image quality and an activity quantification assessment were required to establish the most suitable reconstruction algorithm and corrections for (124)I small animal imaging. |
format | Online Article Text |
id | pubmed-3311594 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Springer |
record_format | MEDLINE/PubMed |
spelling | pubmed-33115942012-03-26 dAcquisition setting optimization and quantitative imaging for (124)I studies with the Inveon microPET-CT system Anizan, Nadège Carlier, Thomas Hindorf, Cecilia Barbet, Jacques Bardiès, Manuel EJNMMI Res Original Research BACKGROUND: Noninvasive multimodality imaging is essential for preclinical evaluation of the biodistribution and pharmacokinetics of radionuclide therapy and for monitoring tumor response. Imaging with nonstandard positron-emission tomography [PET] isotopes such as (124)I is promising in that context but requires accurate activity quantification. The decay scheme of (124)I implies an optimization of both acquisition settings and correction processing. The PET scanner investigated in this study was the Inveon PET/CT system dedicated to small animal imaging. METHODS: The noise equivalent count rate [NECR], the scatter fraction [SF], and the gamma-prompt fraction [GF] were used to determine the best acquisition parameters for mouse- and rat-sized phantoms filled with (124)I. An image-quality phantom as specified by the National Electrical Manufacturers Association NU 4-2008 protocol was acquired and reconstructed with two-dimensional filtered back projection, 2D ordered-subset expectation maximization [2DOSEM], and 3DOSEM with maximum a posteriori [3DOSEM/MAP] algorithms, with and without attenuation correction, scatter correction, and gamma-prompt correction (weighted uniform distribution subtraction). RESULTS: Optimal energy windows were established for the rat phantom (390 to 550 keV) and the mouse phantom (400 to 590 keV) by combining the NECR, SF, and GF results. The coincidence time window had no significant impact regarding the NECR curve variation. Activity concentration of (124)I measured in the uniform region of an image-quality phantom was underestimated by 9.9% for the 3DOSEM/MAP algorithm with attenuation and scatter corrections, and by 23% with the gamma-prompt correction. Attenuation, scatter, and gamma-prompt corrections decreased the residual signal in the cold insert. CONCLUSIONS: The optimal energy windows were chosen with the NECR, SF, and GF evaluation. Nevertheless, an image quality and an activity quantification assessment were required to establish the most suitable reconstruction algorithm and corrections for (124)I small animal imaging. Springer 2012-02-13 /pmc/articles/PMC3311594/ /pubmed/22330760 http://dx.doi.org/10.1186/2191-219X-2-7 Text en Copyright ©2012 Anizan et al; licensee Springer. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Research Anizan, Nadège Carlier, Thomas Hindorf, Cecilia Barbet, Jacques Bardiès, Manuel dAcquisition setting optimization and quantitative imaging for (124)I studies with the Inveon microPET-CT system |
title | dAcquisition setting optimization and quantitative imaging for (124)I studies with the Inveon microPET-CT system |
title_full | dAcquisition setting optimization and quantitative imaging for (124)I studies with the Inveon microPET-CT system |
title_fullStr | dAcquisition setting optimization and quantitative imaging for (124)I studies with the Inveon microPET-CT system |
title_full_unstemmed | dAcquisition setting optimization and quantitative imaging for (124)I studies with the Inveon microPET-CT system |
title_short | dAcquisition setting optimization and quantitative imaging for (124)I studies with the Inveon microPET-CT system |
title_sort | dacquisition setting optimization and quantitative imaging for (124)i studies with the inveon micropet-ct system |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3311594/ https://www.ncbi.nlm.nih.gov/pubmed/22330760 http://dx.doi.org/10.1186/2191-219X-2-7 |
work_keys_str_mv | AT anizannadege dacquisitionsettingoptimizationandquantitativeimagingfor124istudieswiththeinveonmicropetctsystem AT carlierthomas dacquisitionsettingoptimizationandquantitativeimagingfor124istudieswiththeinveonmicropetctsystem AT hindorfcecilia dacquisitionsettingoptimizationandquantitativeimagingfor124istudieswiththeinveonmicropetctsystem AT barbetjacques dacquisitionsettingoptimizationandquantitativeimagingfor124istudieswiththeinveonmicropetctsystem AT bardiesmanuel dacquisitionsettingoptimizationandquantitativeimagingfor124istudieswiththeinveonmicropetctsystem |