Cargando…

Measurement and Analysis of Microwave Frequency Signals Transmitted through the Breast

Microwave approaches to breast imaging include the measurement of signals transmitted through and reflected from the breast. Prototype systems typically feature sensors separated from the breast, resulting in measurements that include the effects of the environment and system. To gain insight into t...

Descripción completa

Detalles Bibliográficos
Autores principales: Bourqui, Jeremie, Garrett, John, Fear, Elise
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3312383/
https://www.ncbi.nlm.nih.gov/pubmed/22481904
http://dx.doi.org/10.1155/2012/562563
_version_ 1782227853129023488
author Bourqui, Jeremie
Garrett, John
Fear, Elise
author_facet Bourqui, Jeremie
Garrett, John
Fear, Elise
author_sort Bourqui, Jeremie
collection PubMed
description Microwave approaches to breast imaging include the measurement of signals transmitted through and reflected from the breast. Prototype systems typically feature sensors separated from the breast, resulting in measurements that include the effects of the environment and system. To gain insight into transmission of microwave signals through the breast, a system that places sensors in direct contact with the breast is proposed. The system also includes a lossy immersion medium that enables measurement of the signal passing through the breast while significantly attenuating signals traveling along other paths. Collecting measurements at different separations between sensors also provides the opportunity to estimate the average electrical properties of the breast tissues. After validation through simulations and measurements, a study of 10 volunteers was performed. Results indicate symmetry between the right and left breast and demonstrate differences in attenuation, maximum frequency for reliable measurement, and average properties that likely relate to variations in breast composition.
format Online
Article
Text
id pubmed-3312383
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-33123832012-04-05 Measurement and Analysis of Microwave Frequency Signals Transmitted through the Breast Bourqui, Jeremie Garrett, John Fear, Elise Int J Biomed Imaging Research Article Microwave approaches to breast imaging include the measurement of signals transmitted through and reflected from the breast. Prototype systems typically feature sensors separated from the breast, resulting in measurements that include the effects of the environment and system. To gain insight into transmission of microwave signals through the breast, a system that places sensors in direct contact with the breast is proposed. The system also includes a lossy immersion medium that enables measurement of the signal passing through the breast while significantly attenuating signals traveling along other paths. Collecting measurements at different separations between sensors also provides the opportunity to estimate the average electrical properties of the breast tissues. After validation through simulations and measurements, a study of 10 volunteers was performed. Results indicate symmetry between the right and left breast and demonstrate differences in attenuation, maximum frequency for reliable measurement, and average properties that likely relate to variations in breast composition. Hindawi Publishing Corporation 2012 2012-03-07 /pmc/articles/PMC3312383/ /pubmed/22481904 http://dx.doi.org/10.1155/2012/562563 Text en Copyright © 2012 Jeremie Bourqui et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Bourqui, Jeremie
Garrett, John
Fear, Elise
Measurement and Analysis of Microwave Frequency Signals Transmitted through the Breast
title Measurement and Analysis of Microwave Frequency Signals Transmitted through the Breast
title_full Measurement and Analysis of Microwave Frequency Signals Transmitted through the Breast
title_fullStr Measurement and Analysis of Microwave Frequency Signals Transmitted through the Breast
title_full_unstemmed Measurement and Analysis of Microwave Frequency Signals Transmitted through the Breast
title_short Measurement and Analysis of Microwave Frequency Signals Transmitted through the Breast
title_sort measurement and analysis of microwave frequency signals transmitted through the breast
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3312383/
https://www.ncbi.nlm.nih.gov/pubmed/22481904
http://dx.doi.org/10.1155/2012/562563
work_keys_str_mv AT bourquijeremie measurementandanalysisofmicrowavefrequencysignalstransmittedthroughthebreast
AT garrettjohn measurementandanalysisofmicrowavefrequencysignalstransmittedthroughthebreast
AT fearelise measurementandanalysisofmicrowavefrequencysignalstransmittedthroughthebreast