Cargando…
Preparation of a Polypyrrole-Polyvinylsulphonate Composite Film Biosensor for Determination of Cholesterol Based on Entrapment of Cholesterol Oxidase
In this paper, a novel amperometric cholesterol biosensor with immobilization of cholesterol oxidase on electrochemically polymerized polypyrrole–polyvinylsulphonate (PPy–PVS) films has been accomplished via the entrapment technique on the surface of a platinum electrode. Electropolymerization of py...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3312452/ https://www.ncbi.nlm.nih.gov/pubmed/22454593 http://dx.doi.org/10.3390/s90806435 |
_version_ | 1782227862164602880 |
---|---|
author | Yıldırımoğlu, Fadime Arslan, Fatma Çete, Servet Yaşar, Ahmet |
author_facet | Yıldırımoğlu, Fadime Arslan, Fatma Çete, Servet Yaşar, Ahmet |
author_sort | Yıldırımoğlu, Fadime |
collection | PubMed |
description | In this paper, a novel amperometric cholesterol biosensor with immobilization of cholesterol oxidase on electrochemically polymerized polypyrrole–polyvinylsulphonate (PPy–PVS) films has been accomplished via the entrapment technique on the surface of a platinum electrode. Electropolymerization of pyrrole and polyvinylsulphonate on the Pt surface was carried out by cyclic voltammetry between −1.0 and +2.0 V (vs. Ag/AgCl) at a scan rate of 100 mV upon the Pt electrode with an electrochemical cell containing pyrrole and polyvinylsulphonate. The amperometric determination is based on the electrochemical detection of H(2)O(2) generated in the enzymatic reaction of cholesterol. Determination of cholesterol was carried out by the oxidation of enzymatically produced H(2)O(2) at 0.4 V vs. Ag/AgCl. The effects of pH and temperature were investigated and optimum parameters were found to be 7.25 and 35 °C, respectively. The storage stability and operational stability of the enzyme electrode were also studied. The results show that 32% of the response current was retained after 19 activity assays. The prepared cholesterol biosensor retained 43% of initial activity after 45 days when stored in 0.1 M phosphate buffer solution at 4 °C. |
format | Online Article Text |
id | pubmed-3312452 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-33124522012-03-27 Preparation of a Polypyrrole-Polyvinylsulphonate Composite Film Biosensor for Determination of Cholesterol Based on Entrapment of Cholesterol Oxidase Yıldırımoğlu, Fadime Arslan, Fatma Çete, Servet Yaşar, Ahmet Sensors (Basel) Article In this paper, a novel amperometric cholesterol biosensor with immobilization of cholesterol oxidase on electrochemically polymerized polypyrrole–polyvinylsulphonate (PPy–PVS) films has been accomplished via the entrapment technique on the surface of a platinum electrode. Electropolymerization of pyrrole and polyvinylsulphonate on the Pt surface was carried out by cyclic voltammetry between −1.0 and +2.0 V (vs. Ag/AgCl) at a scan rate of 100 mV upon the Pt electrode with an electrochemical cell containing pyrrole and polyvinylsulphonate. The amperometric determination is based on the electrochemical detection of H(2)O(2) generated in the enzymatic reaction of cholesterol. Determination of cholesterol was carried out by the oxidation of enzymatically produced H(2)O(2) at 0.4 V vs. Ag/AgCl. The effects of pH and temperature were investigated and optimum parameters were found to be 7.25 and 35 °C, respectively. The storage stability and operational stability of the enzyme electrode were also studied. The results show that 32% of the response current was retained after 19 activity assays. The prepared cholesterol biosensor retained 43% of initial activity after 45 days when stored in 0.1 M phosphate buffer solution at 4 °C. Molecular Diversity Preservation International (MDPI) 2009-08-20 /pmc/articles/PMC3312452/ /pubmed/22454593 http://dx.doi.org/10.3390/s90806435 Text en © 2009 by the authors; licensee MDPI, Basel, Switzerland This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Yıldırımoğlu, Fadime Arslan, Fatma Çete, Servet Yaşar, Ahmet Preparation of a Polypyrrole-Polyvinylsulphonate Composite Film Biosensor for Determination of Cholesterol Based on Entrapment of Cholesterol Oxidase |
title | Preparation of a Polypyrrole-Polyvinylsulphonate Composite Film Biosensor for Determination of Cholesterol Based on Entrapment of Cholesterol Oxidase |
title_full | Preparation of a Polypyrrole-Polyvinylsulphonate Composite Film Biosensor for Determination of Cholesterol Based on Entrapment of Cholesterol Oxidase |
title_fullStr | Preparation of a Polypyrrole-Polyvinylsulphonate Composite Film Biosensor for Determination of Cholesterol Based on Entrapment of Cholesterol Oxidase |
title_full_unstemmed | Preparation of a Polypyrrole-Polyvinylsulphonate Composite Film Biosensor for Determination of Cholesterol Based on Entrapment of Cholesterol Oxidase |
title_short | Preparation of a Polypyrrole-Polyvinylsulphonate Composite Film Biosensor for Determination of Cholesterol Based on Entrapment of Cholesterol Oxidase |
title_sort | preparation of a polypyrrole-polyvinylsulphonate composite film biosensor for determination of cholesterol based on entrapment of cholesterol oxidase |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3312452/ https://www.ncbi.nlm.nih.gov/pubmed/22454593 http://dx.doi.org/10.3390/s90806435 |
work_keys_str_mv | AT yıldırımoglufadime preparationofapolypyrrolepolyvinylsulphonatecompositefilmbiosensorfordeterminationofcholesterolbasedonentrapmentofcholesteroloxidase AT arslanfatma preparationofapolypyrrolepolyvinylsulphonatecompositefilmbiosensorfordeterminationofcholesterolbasedonentrapmentofcholesteroloxidase AT ceteservet preparationofapolypyrrolepolyvinylsulphonatecompositefilmbiosensorfordeterminationofcholesterolbasedonentrapmentofcholesteroloxidase AT yasarahmet preparationofapolypyrrolepolyvinylsulphonatecompositefilmbiosensorfordeterminationofcholesterolbasedonentrapmentofcholesteroloxidase |