A new automated system to identify a consistent sampling position to make tissue Doppler and transmitral Doppler measurements of E, E′ and E/E′()()

BACKGROUND: Transmitral pulse wave (PW) Doppler and annular tissue Doppler velocity measurements provide valuable diagnostic and prognostic information. However, they depend on an echocardiographer manually selecting positions to make the measurements. This is time-consuming and open to variability,...

Descripción completa

Detalles Bibliográficos
Autores principales: Dhutia, Niti M., Cole, Graham D., Willson, Keith, Rueckert, Daniel, Parker, Kim H., Hughes, Alun D., Francis, Darrel P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3314963/
https://www.ncbi.nlm.nih.gov/pubmed/21093935
http://dx.doi.org/10.1016/j.ijcard.2010.10.048
_version_ 1782228174357135360
author Dhutia, Niti M.
Cole, Graham D.
Willson, Keith
Rueckert, Daniel
Parker, Kim H.
Hughes, Alun D.
Francis, Darrel P.
author_facet Dhutia, Niti M.
Cole, Graham D.
Willson, Keith
Rueckert, Daniel
Parker, Kim H.
Hughes, Alun D.
Francis, Darrel P.
author_sort Dhutia, Niti M.
collection PubMed
description BACKGROUND: Transmitral pulse wave (PW) Doppler and annular tissue Doppler velocity measurements provide valuable diagnostic and prognostic information. However, they depend on an echocardiographer manually selecting positions to make the measurements. This is time-consuming and open to variability, especially by less experienced operators. We present a new, automated method to select consistent Doppler velocity sites to measure blood flow and muscle function. METHODS: Our automated algorithm combines speckle tracking and colour flow mapping to locate the septal and lateral mitral valve annuli (to measure peak early diastolic velocity, E′) and the mitral valve inflow (to measure peak inflow velocity, E). We also automate peak velocity measurements from resulting PW Doppler traces. The algorithm-selected locations and time taken to identify them were compared against a panel of echo specialists — the current “gold standard”. RESULTS: The algorithm identified positions to measure Doppler velocities within 3.6 ± 2.2 mm (mitral inflow), 3.2 ± 1.8 mm (septal annulus) and 3.8 ± 1.5 mm (lateral annulus) of the consensus of 3 specialists. This was less than the average 4 mm fidelity with which the specialists could themselves identify the points. The automated algorithm could potentially reduce the time taken to make these measurements by 60 ± 15%. CONCLUSIONS: Our automated algorithm identified sampling positions for measurement of mitral flow, septal and lateral tissue velocities as reliably as specialists. It provides a rapid, easy method for new specialists and potentially non-specialists to make automated measurements of key cardiac physiological indices. This could help support decision-making, without introducing delay and extend availability of echocardiography to more patients.
format Online
Article
Text
id pubmed-3314963
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-33149632012-04-11 A new automated system to identify a consistent sampling position to make tissue Doppler and transmitral Doppler measurements of E, E′ and E/E′()() Dhutia, Niti M. Cole, Graham D. Willson, Keith Rueckert, Daniel Parker, Kim H. Hughes, Alun D. Francis, Darrel P. Int J Cardiol Article BACKGROUND: Transmitral pulse wave (PW) Doppler and annular tissue Doppler velocity measurements provide valuable diagnostic and prognostic information. However, they depend on an echocardiographer manually selecting positions to make the measurements. This is time-consuming and open to variability, especially by less experienced operators. We present a new, automated method to select consistent Doppler velocity sites to measure blood flow and muscle function. METHODS: Our automated algorithm combines speckle tracking and colour flow mapping to locate the septal and lateral mitral valve annuli (to measure peak early diastolic velocity, E′) and the mitral valve inflow (to measure peak inflow velocity, E). We also automate peak velocity measurements from resulting PW Doppler traces. The algorithm-selected locations and time taken to identify them were compared against a panel of echo specialists — the current “gold standard”. RESULTS: The algorithm identified positions to measure Doppler velocities within 3.6 ± 2.2 mm (mitral inflow), 3.2 ± 1.8 mm (septal annulus) and 3.8 ± 1.5 mm (lateral annulus) of the consensus of 3 specialists. This was less than the average 4 mm fidelity with which the specialists could themselves identify the points. The automated algorithm could potentially reduce the time taken to make these measurements by 60 ± 15%. CONCLUSIONS: Our automated algorithm identified sampling positions for measurement of mitral flow, septal and lateral tissue velocities as reliably as specialists. It provides a rapid, easy method for new specialists and potentially non-specialists to make automated measurements of key cardiac physiological indices. This could help support decision-making, without introducing delay and extend availability of echocardiography to more patients. Elsevier 2012-03-22 /pmc/articles/PMC3314963/ /pubmed/21093935 http://dx.doi.org/10.1016/j.ijcard.2010.10.048 Text en © 2012 Elsevier Ireland Ltd. https://creativecommons.org/licenses/by-nc-nd/3.0/ Open Access under CC BY-NC-ND 3.0 (https://creativecommons.org/licenses/by-nc-nd/3.0/) license
spellingShingle Article
Dhutia, Niti M.
Cole, Graham D.
Willson, Keith
Rueckert, Daniel
Parker, Kim H.
Hughes, Alun D.
Francis, Darrel P.
A new automated system to identify a consistent sampling position to make tissue Doppler and transmitral Doppler measurements of E, E′ and E/E′()()
title A new automated system to identify a consistent sampling position to make tissue Doppler and transmitral Doppler measurements of E, E′ and E/E′()()
title_full A new automated system to identify a consistent sampling position to make tissue Doppler and transmitral Doppler measurements of E, E′ and E/E′()()
title_fullStr A new automated system to identify a consistent sampling position to make tissue Doppler and transmitral Doppler measurements of E, E′ and E/E′()()
title_full_unstemmed A new automated system to identify a consistent sampling position to make tissue Doppler and transmitral Doppler measurements of E, E′ and E/E′()()
title_short A new automated system to identify a consistent sampling position to make tissue Doppler and transmitral Doppler measurements of E, E′ and E/E′()()
title_sort new automated system to identify a consistent sampling position to make tissue doppler and transmitral doppler measurements of e, e′ and e/e′()()
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3314963/
https://www.ncbi.nlm.nih.gov/pubmed/21093935
http://dx.doi.org/10.1016/j.ijcard.2010.10.048
work_keys_str_mv AT dhutianitim anewautomatedsystemtoidentifyaconsistentsamplingpositiontomaketissuedopplerandtransmitraldopplermeasurementsofeeandee
AT colegrahamd anewautomatedsystemtoidentifyaconsistentsamplingpositiontomaketissuedopplerandtransmitraldopplermeasurementsofeeandee
AT willsonkeith anewautomatedsystemtoidentifyaconsistentsamplingpositiontomaketissuedopplerandtransmitraldopplermeasurementsofeeandee
AT rueckertdaniel anewautomatedsystemtoidentifyaconsistentsamplingpositiontomaketissuedopplerandtransmitraldopplermeasurementsofeeandee
AT parkerkimh anewautomatedsystemtoidentifyaconsistentsamplingpositiontomaketissuedopplerandtransmitraldopplermeasurementsofeeandee
AT hughesalund anewautomatedsystemtoidentifyaconsistentsamplingpositiontomaketissuedopplerandtransmitraldopplermeasurementsofeeandee
AT francisdarrelp anewautomatedsystemtoidentifyaconsistentsamplingpositiontomaketissuedopplerandtransmitraldopplermeasurementsofeeandee
AT dhutianitim newautomatedsystemtoidentifyaconsistentsamplingpositiontomaketissuedopplerandtransmitraldopplermeasurementsofeeandee
AT colegrahamd newautomatedsystemtoidentifyaconsistentsamplingpositiontomaketissuedopplerandtransmitraldopplermeasurementsofeeandee
AT willsonkeith newautomatedsystemtoidentifyaconsistentsamplingpositiontomaketissuedopplerandtransmitraldopplermeasurementsofeeandee
AT rueckertdaniel newautomatedsystemtoidentifyaconsistentsamplingpositiontomaketissuedopplerandtransmitraldopplermeasurementsofeeandee
AT parkerkimh newautomatedsystemtoidentifyaconsistentsamplingpositiontomaketissuedopplerandtransmitraldopplermeasurementsofeeandee
AT hughesalund newautomatedsystemtoidentifyaconsistentsamplingpositiontomaketissuedopplerandtransmitraldopplermeasurementsofeeandee
AT francisdarrelp newautomatedsystemtoidentifyaconsistentsamplingpositiontomaketissuedopplerandtransmitraldopplermeasurementsofeeandee