Cargando…
The Concept of Equivalent Radon Concentration for Practical Consideration of Indoor Exposure to Thoron
To consider the total exposure to indoor radon and thoron, a concept of equivalent radon concentration for thoron is introduced, defined as the radon concentration that delivers the same annual effective dose as that resulting from the thoron concentration. The total indoor exposure to radon and tho...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3315068/ https://www.ncbi.nlm.nih.gov/pubmed/22470292 http://dx.doi.org/10.3390/ijerph9010286 |
_version_ | 1782228190158127104 |
---|---|
author | Chen, Jing Moir, Deborah |
author_facet | Chen, Jing Moir, Deborah |
author_sort | Chen, Jing |
collection | PubMed |
description | To consider the total exposure to indoor radon and thoron, a concept of equivalent radon concentration for thoron is introduced, defined as the radon concentration that delivers the same annual effective dose as that resulting from the thoron concentration. The total indoor exposure to radon and thoron is then the sum of the radon concentration and the equivalent radon concentration for thoron. The total exposure should be compared to the radon guideline value, and if it exceeds the guideline value, appropriate remedial action is required. With this concept, a separate guideline for indoor thoron exposure is not necessary. For homes already tested for radon with radon detectors, Health Canada’s recommendation of a 3-month radon test performed during the fall/winter heating season not only ensures a conservative estimate of the annual average radon concentration but also covers well any potentially missing contribution from thoron exposure. In addition, because the thoron concentration is much lower than the radon concentration in most homes in Canada, there is no real need to re-test homes for thoron. |
format | Online Article Text |
id | pubmed-3315068 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-33150682012-04-02 The Concept of Equivalent Radon Concentration for Practical Consideration of Indoor Exposure to Thoron Chen, Jing Moir, Deborah Int J Environ Res Public Health Article To consider the total exposure to indoor radon and thoron, a concept of equivalent radon concentration for thoron is introduced, defined as the radon concentration that delivers the same annual effective dose as that resulting from the thoron concentration. The total indoor exposure to radon and thoron is then the sum of the radon concentration and the equivalent radon concentration for thoron. The total exposure should be compared to the radon guideline value, and if it exceeds the guideline value, appropriate remedial action is required. With this concept, a separate guideline for indoor thoron exposure is not necessary. For homes already tested for radon with radon detectors, Health Canada’s recommendation of a 3-month radon test performed during the fall/winter heating season not only ensures a conservative estimate of the annual average radon concentration but also covers well any potentially missing contribution from thoron exposure. In addition, because the thoron concentration is much lower than the radon concentration in most homes in Canada, there is no real need to re-test homes for thoron. MDPI 2012-01-18 2012-01 /pmc/articles/PMC3315068/ /pubmed/22470292 http://dx.doi.org/10.3390/ijerph9010286 Text en © 2012 by the authors; licensee MDPI, Basel, Switzerland. http://creativecommons.org/licenses/by/3.0/ This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Chen, Jing Moir, Deborah The Concept of Equivalent Radon Concentration for Practical Consideration of Indoor Exposure to Thoron |
title | The Concept of Equivalent Radon Concentration for Practical Consideration of Indoor Exposure to Thoron |
title_full | The Concept of Equivalent Radon Concentration for Practical Consideration of Indoor Exposure to Thoron |
title_fullStr | The Concept of Equivalent Radon Concentration for Practical Consideration of Indoor Exposure to Thoron |
title_full_unstemmed | The Concept of Equivalent Radon Concentration for Practical Consideration of Indoor Exposure to Thoron |
title_short | The Concept of Equivalent Radon Concentration for Practical Consideration of Indoor Exposure to Thoron |
title_sort | concept of equivalent radon concentration for practical consideration of indoor exposure to thoron |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3315068/ https://www.ncbi.nlm.nih.gov/pubmed/22470292 http://dx.doi.org/10.3390/ijerph9010286 |
work_keys_str_mv | AT chenjing theconceptofequivalentradonconcentrationforpracticalconsiderationofindoorexposuretothoron AT moirdeborah theconceptofequivalentradonconcentrationforpracticalconsiderationofindoorexposuretothoron AT chenjing conceptofequivalentradonconcentrationforpracticalconsiderationofindoorexposuretothoron AT moirdeborah conceptofequivalentradonconcentrationforpracticalconsiderationofindoorexposuretothoron |