Cargando…

Microencapsulated 3-Dimensional Sensor for the Measurement of Oxygen in Single Isolated Pancreatic Islets

BACKGROUND: Oxygen consumption reflects multiple processes in pancreatic islets including mechanisms contributing to insulin secretion, oxidative stress and viability, providing an important readout in studies of islet function, islet viability and drug testing. Due to the scarcity, heterogeneity, a...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Wanyu, Lisowski, Mark, Khalil, Gamal, Sweet, Ian R., Shen, Amy Q.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3315556/
https://www.ncbi.nlm.nih.gov/pubmed/22479359
http://dx.doi.org/10.1371/journal.pone.0033070
_version_ 1782228255881822208
author Chen, Wanyu
Lisowski, Mark
Khalil, Gamal
Sweet, Ian R.
Shen, Amy Q.
author_facet Chen, Wanyu
Lisowski, Mark
Khalil, Gamal
Sweet, Ian R.
Shen, Amy Q.
author_sort Chen, Wanyu
collection PubMed
description BACKGROUND: Oxygen consumption reflects multiple processes in pancreatic islets including mechanisms contributing to insulin secretion, oxidative stress and viability, providing an important readout in studies of islet function, islet viability and drug testing. Due to the scarcity, heterogeneity, and intrinsic kinetic properties of individual islets, it would be of great benefit to detect oxygen consumption by single islets. We present a novel method we have developed to image oxygen in single islets. METHODOLOGY/PRINCIPAL FINDINGS: Using a microfluidics system, individual islets and a fluorescent oxygen-sensitive dye were encased within a thin alginate polymer layer. Insulin secretion by the encapsulated islets was normal. Fluorescent signal from the encased dye, detected using a standard inverted fluorescence microscope and digital camera, was stable and proportional to the amount of oxygen in the media. When integrated into a perifusion system, the sensing system detected changes in response to metabolic substrates, mitochondrial poisons, and induced-oscillations. Glucose responses averaged 30.1±7.1% of the response to a metabolic inhibitor (cyanide), increases were observed in all cases (n = 6), and the system was able to resolve changes in oxygen consumption that had a period greater than 0.5 minutes. The sensing system operated similarly from 2–48 hours following encapsulation, and viability and function of the islets were not significantly affected by the encapsulation process. CONCLUSIONS/SIGNIFICANCE: An oxygen-dependent dye situated around and within a pancreatic islet encapsulated by a thin layer of alginate was sensitive to changes in oxygen consumption, and was not harmful to the function or viability of islets over the course of two days. The microcapsule-based sensing method is particularly suited to assessing the effects of compounds (dose responses and time courses) and chronic changes occurring over the course of days. The approach should be applicable to other cell types and dyes sensitive to other biologically important molecules.
format Online
Article
Text
id pubmed-3315556
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-33155562012-04-04 Microencapsulated 3-Dimensional Sensor for the Measurement of Oxygen in Single Isolated Pancreatic Islets Chen, Wanyu Lisowski, Mark Khalil, Gamal Sweet, Ian R. Shen, Amy Q. PLoS One Research Article BACKGROUND: Oxygen consumption reflects multiple processes in pancreatic islets including mechanisms contributing to insulin secretion, oxidative stress and viability, providing an important readout in studies of islet function, islet viability and drug testing. Due to the scarcity, heterogeneity, and intrinsic kinetic properties of individual islets, it would be of great benefit to detect oxygen consumption by single islets. We present a novel method we have developed to image oxygen in single islets. METHODOLOGY/PRINCIPAL FINDINGS: Using a microfluidics system, individual islets and a fluorescent oxygen-sensitive dye were encased within a thin alginate polymer layer. Insulin secretion by the encapsulated islets was normal. Fluorescent signal from the encased dye, detected using a standard inverted fluorescence microscope and digital camera, was stable and proportional to the amount of oxygen in the media. When integrated into a perifusion system, the sensing system detected changes in response to metabolic substrates, mitochondrial poisons, and induced-oscillations. Glucose responses averaged 30.1±7.1% of the response to a metabolic inhibitor (cyanide), increases were observed in all cases (n = 6), and the system was able to resolve changes in oxygen consumption that had a period greater than 0.5 minutes. The sensing system operated similarly from 2–48 hours following encapsulation, and viability and function of the islets were not significantly affected by the encapsulation process. CONCLUSIONS/SIGNIFICANCE: An oxygen-dependent dye situated around and within a pancreatic islet encapsulated by a thin layer of alginate was sensitive to changes in oxygen consumption, and was not harmful to the function or viability of islets over the course of two days. The microcapsule-based sensing method is particularly suited to assessing the effects of compounds (dose responses and time courses) and chronic changes occurring over the course of days. The approach should be applicable to other cell types and dyes sensitive to other biologically important molecules. Public Library of Science 2012-03-29 /pmc/articles/PMC3315556/ /pubmed/22479359 http://dx.doi.org/10.1371/journal.pone.0033070 Text en Chen et al. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Chen, Wanyu
Lisowski, Mark
Khalil, Gamal
Sweet, Ian R.
Shen, Amy Q.
Microencapsulated 3-Dimensional Sensor for the Measurement of Oxygen in Single Isolated Pancreatic Islets
title Microencapsulated 3-Dimensional Sensor for the Measurement of Oxygen in Single Isolated Pancreatic Islets
title_full Microencapsulated 3-Dimensional Sensor for the Measurement of Oxygen in Single Isolated Pancreatic Islets
title_fullStr Microencapsulated 3-Dimensional Sensor for the Measurement of Oxygen in Single Isolated Pancreatic Islets
title_full_unstemmed Microencapsulated 3-Dimensional Sensor for the Measurement of Oxygen in Single Isolated Pancreatic Islets
title_short Microencapsulated 3-Dimensional Sensor for the Measurement of Oxygen in Single Isolated Pancreatic Islets
title_sort microencapsulated 3-dimensional sensor for the measurement of oxygen in single isolated pancreatic islets
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3315556/
https://www.ncbi.nlm.nih.gov/pubmed/22479359
http://dx.doi.org/10.1371/journal.pone.0033070
work_keys_str_mv AT chenwanyu microencapsulated3dimensionalsensorforthemeasurementofoxygeninsingleisolatedpancreaticislets
AT lisowskimark microencapsulated3dimensionalsensorforthemeasurementofoxygeninsingleisolatedpancreaticislets
AT khalilgamal microencapsulated3dimensionalsensorforthemeasurementofoxygeninsingleisolatedpancreaticislets
AT sweetianr microencapsulated3dimensionalsensorforthemeasurementofoxygeninsingleisolatedpancreaticislets
AT shenamyq microencapsulated3dimensionalsensorforthemeasurementofoxygeninsingleisolatedpancreaticislets