Cargando…

Comparison of Fetal Nuchal Fold Thickness Measurements by Two- and Three-Dimensional Ultrasonography (3DXI Multislice View)

Purpose. To compare the measurements of fetal nuchal fold (NF) thickness by two-dimensional (2D) and three-dimensional (3D) ultrasonography using the three-dimensional extended imaging (3DXI). Methods. A cross-sectional study was performed with 60 healthy pregnant women with a gestational age betwee...

Descripción completa

Detalles Bibliográficos
Autores principales: de Freitas, Leonardo da Silva Valladão, de Bello Barros, Fernanda Silveira, Negrini, Rômulo, de Silva Bussamra, Luiz Cláudio, Araujo Júnior, Edward, Piato, Sebastião, Nardozza, Luciano Marcondes Machado, Moron, Antonio Fernandes, Aoki, Tsutomu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3317015/
https://www.ncbi.nlm.nih.gov/pubmed/22529858
http://dx.doi.org/10.1155/2012/837307
_version_ 1782228489587392512
author de Freitas, Leonardo da Silva Valladão
de Bello Barros, Fernanda Silveira
Negrini, Rômulo
de Silva Bussamra, Luiz Cláudio
Araujo Júnior, Edward
Piato, Sebastião
Nardozza, Luciano Marcondes Machado
Moron, Antonio Fernandes
Aoki, Tsutomu
author_facet de Freitas, Leonardo da Silva Valladão
de Bello Barros, Fernanda Silveira
Negrini, Rômulo
de Silva Bussamra, Luiz Cláudio
Araujo Júnior, Edward
Piato, Sebastião
Nardozza, Luciano Marcondes Machado
Moron, Antonio Fernandes
Aoki, Tsutomu
author_sort de Freitas, Leonardo da Silva Valladão
collection PubMed
description Purpose. To compare the measurements of fetal nuchal fold (NF) thickness by two-dimensional (2D) and three-dimensional (3D) ultrasonography using the three-dimensional extended imaging (3DXI). Methods. A cross-sectional study was performed with 60 healthy pregnant women with a gestational age between 16 and 20 weeks and 6 days. The 2D-NF measurements were made as the distance from the outer skull bone to the outer skin surface in the transverse axial image in the suboccipital-bregmatic plane of the head. For the 3D we employed the 3DXI multislice view software, in which 3 × 2 tomographic planes was displayed on the screen and the distance between the tomographic slices was 0.5 mm. Maximum, minimum, mean, and standard deviation were calculated for 2D and 3D ultrasonography, as well the maximum and minimum, mean, and standard deviation for the difference between both methods. The Wilcoxon signed-rank test was used to compare the two different techniques. Results. 2D-NF showed a mean of thickness of 3.52 ± 0.95 mm (1.69–7.14). The mean of 3D-NF was 3.90 ± 1.02 mm (2.13–7.72). The mean difference between the methods was 0.38 mm, with a maximum difference of 3.12 mm. Conclusion. The NF thickness measurements obtained by 3D ultrasonography were significantly larger than those detected with 2D ultrasonography.
format Online
Article
Text
id pubmed-3317015
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-33170152012-04-23 Comparison of Fetal Nuchal Fold Thickness Measurements by Two- and Three-Dimensional Ultrasonography (3DXI Multislice View) de Freitas, Leonardo da Silva Valladão de Bello Barros, Fernanda Silveira Negrini, Rômulo de Silva Bussamra, Luiz Cláudio Araujo Júnior, Edward Piato, Sebastião Nardozza, Luciano Marcondes Machado Moron, Antonio Fernandes Aoki, Tsutomu Obstet Gynecol Int Clinical Study Purpose. To compare the measurements of fetal nuchal fold (NF) thickness by two-dimensional (2D) and three-dimensional (3D) ultrasonography using the three-dimensional extended imaging (3DXI). Methods. A cross-sectional study was performed with 60 healthy pregnant women with a gestational age between 16 and 20 weeks and 6 days. The 2D-NF measurements were made as the distance from the outer skull bone to the outer skin surface in the transverse axial image in the suboccipital-bregmatic plane of the head. For the 3D we employed the 3DXI multislice view software, in which 3 × 2 tomographic planes was displayed on the screen and the distance between the tomographic slices was 0.5 mm. Maximum, minimum, mean, and standard deviation were calculated for 2D and 3D ultrasonography, as well the maximum and minimum, mean, and standard deviation for the difference between both methods. The Wilcoxon signed-rank test was used to compare the two different techniques. Results. 2D-NF showed a mean of thickness of 3.52 ± 0.95 mm (1.69–7.14). The mean of 3D-NF was 3.90 ± 1.02 mm (2.13–7.72). The mean difference between the methods was 0.38 mm, with a maximum difference of 3.12 mm. Conclusion. The NF thickness measurements obtained by 3D ultrasonography were significantly larger than those detected with 2D ultrasonography. Hindawi Publishing Corporation 2012 2012-02-20 /pmc/articles/PMC3317015/ /pubmed/22529858 http://dx.doi.org/10.1155/2012/837307 Text en Copyright © 2012 Leonardo da Silva Valladão de Freitas et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Study
de Freitas, Leonardo da Silva Valladão
de Bello Barros, Fernanda Silveira
Negrini, Rômulo
de Silva Bussamra, Luiz Cláudio
Araujo Júnior, Edward
Piato, Sebastião
Nardozza, Luciano Marcondes Machado
Moron, Antonio Fernandes
Aoki, Tsutomu
Comparison of Fetal Nuchal Fold Thickness Measurements by Two- and Three-Dimensional Ultrasonography (3DXI Multislice View)
title Comparison of Fetal Nuchal Fold Thickness Measurements by Two- and Three-Dimensional Ultrasonography (3DXI Multislice View)
title_full Comparison of Fetal Nuchal Fold Thickness Measurements by Two- and Three-Dimensional Ultrasonography (3DXI Multislice View)
title_fullStr Comparison of Fetal Nuchal Fold Thickness Measurements by Two- and Three-Dimensional Ultrasonography (3DXI Multislice View)
title_full_unstemmed Comparison of Fetal Nuchal Fold Thickness Measurements by Two- and Three-Dimensional Ultrasonography (3DXI Multislice View)
title_short Comparison of Fetal Nuchal Fold Thickness Measurements by Two- and Three-Dimensional Ultrasonography (3DXI Multislice View)
title_sort comparison of fetal nuchal fold thickness measurements by two- and three-dimensional ultrasonography (3dxi multislice view)
topic Clinical Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3317015/
https://www.ncbi.nlm.nih.gov/pubmed/22529858
http://dx.doi.org/10.1155/2012/837307
work_keys_str_mv AT defreitasleonardodasilvavalladao comparisonoffetalnuchalfoldthicknessmeasurementsbytwoandthreedimensionalultrasonography3dximultisliceview
AT debellobarrosfernandasilveira comparisonoffetalnuchalfoldthicknessmeasurementsbytwoandthreedimensionalultrasonography3dximultisliceview
AT negriniromulo comparisonoffetalnuchalfoldthicknessmeasurementsbytwoandthreedimensionalultrasonography3dximultisliceview
AT desilvabussamraluizclaudio comparisonoffetalnuchalfoldthicknessmeasurementsbytwoandthreedimensionalultrasonography3dximultisliceview
AT araujojunioredward comparisonoffetalnuchalfoldthicknessmeasurementsbytwoandthreedimensionalultrasonography3dximultisliceview
AT piatosebastiao comparisonoffetalnuchalfoldthicknessmeasurementsbytwoandthreedimensionalultrasonography3dximultisliceview
AT nardozzalucianomarcondesmachado comparisonoffetalnuchalfoldthicknessmeasurementsbytwoandthreedimensionalultrasonography3dximultisliceview
AT moronantoniofernandes comparisonoffetalnuchalfoldthicknessmeasurementsbytwoandthreedimensionalultrasonography3dximultisliceview
AT aokitsutomu comparisonoffetalnuchalfoldthicknessmeasurementsbytwoandthreedimensionalultrasonography3dximultisliceview