Cargando…
Comparison of Fetal Nuchal Fold Thickness Measurements by Two- and Three-Dimensional Ultrasonography (3DXI Multislice View)
Purpose. To compare the measurements of fetal nuchal fold (NF) thickness by two-dimensional (2D) and three-dimensional (3D) ultrasonography using the three-dimensional extended imaging (3DXI). Methods. A cross-sectional study was performed with 60 healthy pregnant women with a gestational age betwee...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3317015/ https://www.ncbi.nlm.nih.gov/pubmed/22529858 http://dx.doi.org/10.1155/2012/837307 |
_version_ | 1782228489587392512 |
---|---|
author | de Freitas, Leonardo da Silva Valladão de Bello Barros, Fernanda Silveira Negrini, Rômulo de Silva Bussamra, Luiz Cláudio Araujo Júnior, Edward Piato, Sebastião Nardozza, Luciano Marcondes Machado Moron, Antonio Fernandes Aoki, Tsutomu |
author_facet | de Freitas, Leonardo da Silva Valladão de Bello Barros, Fernanda Silveira Negrini, Rômulo de Silva Bussamra, Luiz Cláudio Araujo Júnior, Edward Piato, Sebastião Nardozza, Luciano Marcondes Machado Moron, Antonio Fernandes Aoki, Tsutomu |
author_sort | de Freitas, Leonardo da Silva Valladão |
collection | PubMed |
description | Purpose. To compare the measurements of fetal nuchal fold (NF) thickness by two-dimensional (2D) and three-dimensional (3D) ultrasonography using the three-dimensional extended imaging (3DXI). Methods. A cross-sectional study was performed with 60 healthy pregnant women with a gestational age between 16 and 20 weeks and 6 days. The 2D-NF measurements were made as the distance from the outer skull bone to the outer skin surface in the transverse axial image in the suboccipital-bregmatic plane of the head. For the 3D we employed the 3DXI multislice view software, in which 3 × 2 tomographic planes was displayed on the screen and the distance between the tomographic slices was 0.5 mm. Maximum, minimum, mean, and standard deviation were calculated for 2D and 3D ultrasonography, as well the maximum and minimum, mean, and standard deviation for the difference between both methods. The Wilcoxon signed-rank test was used to compare the two different techniques. Results. 2D-NF showed a mean of thickness of 3.52 ± 0.95 mm (1.69–7.14). The mean of 3D-NF was 3.90 ± 1.02 mm (2.13–7.72). The mean difference between the methods was 0.38 mm, with a maximum difference of 3.12 mm. Conclusion. The NF thickness measurements obtained by 3D ultrasonography were significantly larger than those detected with 2D ultrasonography. |
format | Online Article Text |
id | pubmed-3317015 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-33170152012-04-23 Comparison of Fetal Nuchal Fold Thickness Measurements by Two- and Three-Dimensional Ultrasonography (3DXI Multislice View) de Freitas, Leonardo da Silva Valladão de Bello Barros, Fernanda Silveira Negrini, Rômulo de Silva Bussamra, Luiz Cláudio Araujo Júnior, Edward Piato, Sebastião Nardozza, Luciano Marcondes Machado Moron, Antonio Fernandes Aoki, Tsutomu Obstet Gynecol Int Clinical Study Purpose. To compare the measurements of fetal nuchal fold (NF) thickness by two-dimensional (2D) and three-dimensional (3D) ultrasonography using the three-dimensional extended imaging (3DXI). Methods. A cross-sectional study was performed with 60 healthy pregnant women with a gestational age between 16 and 20 weeks and 6 days. The 2D-NF measurements were made as the distance from the outer skull bone to the outer skin surface in the transverse axial image in the suboccipital-bregmatic plane of the head. For the 3D we employed the 3DXI multislice view software, in which 3 × 2 tomographic planes was displayed on the screen and the distance between the tomographic slices was 0.5 mm. Maximum, minimum, mean, and standard deviation were calculated for 2D and 3D ultrasonography, as well the maximum and minimum, mean, and standard deviation for the difference between both methods. The Wilcoxon signed-rank test was used to compare the two different techniques. Results. 2D-NF showed a mean of thickness of 3.52 ± 0.95 mm (1.69–7.14). The mean of 3D-NF was 3.90 ± 1.02 mm (2.13–7.72). The mean difference between the methods was 0.38 mm, with a maximum difference of 3.12 mm. Conclusion. The NF thickness measurements obtained by 3D ultrasonography were significantly larger than those detected with 2D ultrasonography. Hindawi Publishing Corporation 2012 2012-02-20 /pmc/articles/PMC3317015/ /pubmed/22529858 http://dx.doi.org/10.1155/2012/837307 Text en Copyright © 2012 Leonardo da Silva Valladão de Freitas et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Study de Freitas, Leonardo da Silva Valladão de Bello Barros, Fernanda Silveira Negrini, Rômulo de Silva Bussamra, Luiz Cláudio Araujo Júnior, Edward Piato, Sebastião Nardozza, Luciano Marcondes Machado Moron, Antonio Fernandes Aoki, Tsutomu Comparison of Fetal Nuchal Fold Thickness Measurements by Two- and Three-Dimensional Ultrasonography (3DXI Multislice View) |
title | Comparison of Fetal Nuchal Fold Thickness Measurements by Two- and Three-Dimensional Ultrasonography (3DXI Multislice View) |
title_full | Comparison of Fetal Nuchal Fold Thickness Measurements by Two- and Three-Dimensional Ultrasonography (3DXI Multislice View) |
title_fullStr | Comparison of Fetal Nuchal Fold Thickness Measurements by Two- and Three-Dimensional Ultrasonography (3DXI Multislice View) |
title_full_unstemmed | Comparison of Fetal Nuchal Fold Thickness Measurements by Two- and Three-Dimensional Ultrasonography (3DXI Multislice View) |
title_short | Comparison of Fetal Nuchal Fold Thickness Measurements by Two- and Three-Dimensional Ultrasonography (3DXI Multislice View) |
title_sort | comparison of fetal nuchal fold thickness measurements by two- and three-dimensional ultrasonography (3dxi multislice view) |
topic | Clinical Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3317015/ https://www.ncbi.nlm.nih.gov/pubmed/22529858 http://dx.doi.org/10.1155/2012/837307 |
work_keys_str_mv | AT defreitasleonardodasilvavalladao comparisonoffetalnuchalfoldthicknessmeasurementsbytwoandthreedimensionalultrasonography3dximultisliceview AT debellobarrosfernandasilveira comparisonoffetalnuchalfoldthicknessmeasurementsbytwoandthreedimensionalultrasonography3dximultisliceview AT negriniromulo comparisonoffetalnuchalfoldthicknessmeasurementsbytwoandthreedimensionalultrasonography3dximultisliceview AT desilvabussamraluizclaudio comparisonoffetalnuchalfoldthicknessmeasurementsbytwoandthreedimensionalultrasonography3dximultisliceview AT araujojunioredward comparisonoffetalnuchalfoldthicknessmeasurementsbytwoandthreedimensionalultrasonography3dximultisliceview AT piatosebastiao comparisonoffetalnuchalfoldthicknessmeasurementsbytwoandthreedimensionalultrasonography3dximultisliceview AT nardozzalucianomarcondesmachado comparisonoffetalnuchalfoldthicknessmeasurementsbytwoandthreedimensionalultrasonography3dximultisliceview AT moronantoniofernandes comparisonoffetalnuchalfoldthicknessmeasurementsbytwoandthreedimensionalultrasonography3dximultisliceview AT aokitsutomu comparisonoffetalnuchalfoldthicknessmeasurementsbytwoandthreedimensionalultrasonography3dximultisliceview |